Literature DB >> 34372467

Performance Analysis of Non-Interferometry Based Surface Plasmon Resonance Microscopes.

Sorawit Tontarawongsa1, Sarinporn Visitsattapongse1, Suejit Pechprasarn2.   

Abstract

Surface plasmon microscopy has been of interest to the science and engineering community and has been utilized in broad aspects of applications and studies, including biochemical sensing and biomolecular binding kinetics. The benefits of surface plasmon microscopy include label-free detection, high sensitivity, and quantitative measurements. Here, a theoretical framework to analyze and compare several non-interferometric surface plasmon microscopes is proposed. The scope of the study is to (1) identify the strengths and weaknesses in each surface plasmon microscopes reported in the literature; (2) quantify their performance in terms of spatial imaging resolution, imaging contrast, sensitivity, and measurement accuracy for quantitative and non-quantitative imaging modes of the microscopes. Six types of non-interferometric microscopes were included in this study: annulus aperture scanning, half annulus aperture scanning, single-point scanning, double-point scanning, single-point scanning, at 45 degrees azimuthal angle, and double-point scanning at 45 degrees azimuthal angle. For non-quantitative imaging, there is a substantial tradeoff between the image contrast and the spatial resolution. For the quantitative imaging, the half annulus aperture provided the highest sensitivity of 127.058 rad/μm2 RIU-1, followed by the full annulus aperture of 126.318 rad/μm2 RIU-1. There is a clear tradeoff between spatial resolution and sensitivity. The annulus aperture and half annulus aperture had an optimal resolution, sensitivity, and crosstalk compared to the other non-interferometric surface plasmon resonance microscopes. The resolution depends strongly on the propagation length of the surface plasmons rather than the numerical aperture of the objective lens. For imaging and sensing purposes, the recommended microfluidic channel size and protein stamping size for surface plasmon resonance experiments is at least 25 μm for accurate plasmonic measurements.

Entities:  

Keywords:  instrumentation; quantitative measurement; surface plasmon microscopy; surface plasmon resonance

Year:  2021        PMID: 34372467     DOI: 10.3390/s21155230

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  1 in total

1.  Analysis of the surface plasmon resonance interferometric imaging performance of scanning confocal surface plasmon microscopy.

Authors:  Sorawit Tontarawongsa; Sarinporn Visitsattapongse; Suejit Pechprasarn
Journal:  Biomed Opt Express       Date:  2021-12-24       Impact factor: 3.732

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.