Literature DB >> 34372377

Remote Patient Monitoring with Wearable Sensors Following Knee Arthroplasty.

Scott M Bolam1,2, Bruno Batinica2, Ted C Yeung3, Sebastian Weaver3, Astrid Cantamessa4, Teresa C Vanderboor1, Shasha Yeung3, Jacob T Munro1,2, Justin W Fernandez3,5, Thor F Besier3,5, Andrew Paul Monk1,2,3.   

Abstract

(Background) Inertial Measurement Units (IMUs) provide a low-cost, portable solution to obtain functional measures similar to those captured with three-dimensional gait analysis, including spatiotemporal gait characteristics. The primary aim of this study was to determine the feasibility of a remote patient monitoring (RPM) workflow using ankle-worn IMUs measuring impact load, limb impact load asymmetry and knee range of motion in combination with patient-reported outcome measures. (Methods) A pilot cohort of 14 patients undergoing primary knee arthroplasty for osteoarthritis was prospectively enrolled. RPM in the community was performed weekly from 2 up to 6 weeks post-operatively using wearable IMUs. The following data were collected using IMUs: mobility (Bone Stimulus and cumulative impact load), impact load asymmetry and maximum knee flexion angle. In addition, scores from the Oxford Knee Score (OKS), EuroQol Five-dimension (EQ-5D) with EuroQol visual analogue scale (EQ-VAS) and 6 Minute Walk Test were collected. (Results) On average, the Bone Stimulus and cumulative impact load improved 52% (p = 0.002) and 371% (p = 0.035), compared to Post-Op Week 2. The impact load asymmetry value trended (p = 0.372) towards equal impact loading between the operative and non-operative limb. The mean maximum flexion angle achieved was 99.25° at Post-Operative Week 6, but this was not significantly different from pre-operative measurements (p = 0.1563). There were significant improvements in the mean EQ-5D (0.20; p = 0.047) and OKS (10.86; p < 0.001) scores both by 6 weeks after surgery, compared to pre-operative scores. (Conclusions) This pilot study demonstrates the feasibility of a reliable and low-maintenance workflow system to remotely monitor post-operative progress in knee arthroplasty patients. Preliminary data indicate IMU outputs relating to mobility, impact load asymmetry and range of motion can be obtained using commercially available IMU sensors. Further studies are required to directly correlate the IMU sensor outputs with patient outcomes to establish clinical significance.

Entities:  

Keywords:  PROMs; inertial measurement unit (IMU); knee arthroplasty; remote monitoring; telemedicine; wearable sensor

Year:  2021        PMID: 34372377     DOI: 10.3390/s21155143

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  2 in total

1.  Orthopedic Telemedicine Outpatient Practice Diagnoses Set during the First COVID-19 Pandemic Lockdown-Individual Observation.

Authors:  Wojciech Michał Glinkowski
Journal:  Int J Environ Res Public Health       Date:  2022-04-29       Impact factor: 4.614

2.  A Novel Walking Activity Recognition Model for Rotation Time Series Collected by a Wearable Sensor in a Free-Living Environment.

Authors:  Raphaël Brard; Lise Bellanger; Laurent Chevreuil; Fanny Doistau; Pierre Drouin; Aymeric Stamm
Journal:  Sensors (Basel)       Date:  2022-05-07       Impact factor: 3.847

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.