67 patients with 176 repaired flexor tendons have been reviewed after a mean interval of 26.4 months. 160 tendons to 100 fingers, and 16 flexor pollicis longus tendons were repaired. When evaluated by Buck-Gramcko criteria, the functional results in 92% of the fingers and 69% of the thumbs were graded as excellent or good. Patients with partially divided tendons fared no better than those whose tendons were completely divided. The results of repair in the little finger were less satisfactory than in other fingers.

Entities:  

Mesh:

Year:  1987        PMID: 3437197     DOI: 10.1016/0266-7681(87)90181-1

Source DB:  PubMed          Journal:  J Hand Surg Br        ISSN: 0266-7681


  4 in total

1.  Modified Brunelli pull-out technique in flexor tendon repair for zone II: a study on 58 cases.

Authors:  Alexandru Valentin Georgescu; Ileana R Matei; Irina M Capota; Filip Ardelean; Octavian D Olariu
Journal:  Hand (N Y)       Date:  2011-07-02

2.  A portable device for finger tendon rehabilitation that provides an isotonic training force and records exercise behaviour after finger tendon surgery.

Authors:  J G Dobbe; N E van Trommel; J E de Freitas Baptista; M J Ritt; A Steenbeek; H A Molenaar
Journal:  Med Biol Eng Comput       Date:  1999-05       Impact factor: 2.602

3.  Flexor pollicis longus tendon injuries in children.

Authors:  A O Grobbelaar; D A Hudson
Journal:  Ann R Coll Surg Engl       Date:  1995-03       Impact factor: 1.891

Review 4.  Negative Predictors of Outcomes of Flexor Tendon Repairs.

Authors:  C M Hurley; Frank Reilly; Simon Callaghan; M N Baig
Journal:  Cureus       Date:  2019-03-23