Literature DB >> 34371447

A tailored extracellular matrix (ECM) - Mimetic coating for cardiovascular stents by stepwise assembly of hyaluronic acid and recombinant human type III collagen.

Li Yang1, Haoshuang Wu1, Lu Lu2, Qing He1, Boting Xi1, Hongchi Yu1, Rifang Luo3, Yunbing Wang4, Xingdong Zhang1.   

Abstract

Collagen, a central component of the extracellular matrix (ECM), has been widely applied in tissue engineering, among others, for wound healing or bone and nerve regeneration. However, the inherent thrombogenic properties of collagen hinder the application in blood-contacting devices. Herein, a brand-new recombinant human type III collagen (hCOLIII) was explored that does not present binding sites for platelets while retaining the affinity for endothelial cells. The hCOLIII together with hyaluronic acid (HA) were deposited on the substrates via layer-by-layer assembly to form an ECM-mimetic multilayer coating. In vitro platelet adhesion and ex vivo blood circulation tests demonstrated prominent thromboprotective properties for the hCOLIII-based ECM-mimetic coating. In addition, the coating effectively guided the vascular cell fate by supporting the proliferation of endothelial cells and inhibiting the proliferation of smooth muscle cells by differentiating them to a more contractile phenotype. A polylactic acid (PLA) stent coated with hCOLIII-based ECM-mimetic coating was implanted in the abdominal aorta of rabbits to investigate the healing of the neointima. The enhanced endothelialization, suppressed inflammatory response, inhibition of excessive neointimal hyperplasia, and the superior thromboprotection strongly indicated the prospect of the hCOLIII-based ECM-mimetic coating as a tailored blood-contacting material for cardiovascular stents.
Copyright © 2021 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Anti-coagulation; Cardiovascular stents; Endothelialization; Extracellular matrix (ECM); Layer-by-layer (LBL) assembly; Recombinant human type III collagen

Year:  2021        PMID: 34371447     DOI: 10.1016/j.biomaterials.2021.121055

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  4 in total

Review 1.  Development of Biodegradable Polymeric Stents for the Treatment of Cardiovascular Diseases.

Authors:  Yihong Shen; Xiao Yu; Jie Cui; Fan Yu; Mingyue Liu; Yujie Chen; Jinglei Wu; Binbin Sun; Xiumei Mo
Journal:  Biomolecules       Date:  2022-09-06

2.  Preparation and Properties of Double-Crosslinked Hydroxyapatite Composite Hydrogels.

Authors:  Benbo Zhao; Mingda Zhao; Liming Li; Shixiong Sun; Heping Yu; Yuan Cheng; Yuedi Yang; Yujiang Fan; Yong Sun
Journal:  Int J Mol Sci       Date:  2022-09-01       Impact factor: 6.208

Review 3.  Sirolimus Release from Biodegradable Polymers for Coronary Stent Application: A Review.

Authors:  Wei Xu; Makoto Sasaki; Takuro Niidome
Journal:  Pharmaceutics       Date:  2022-02-24       Impact factor: 6.321

Review 4.  Applying Principles of Regenerative Medicine to Vascular Stent Development.

Authors:  Prakash Parthiban Selvakumar; Michael Scott Rafuse; Richard Johnson; Wei Tan
Journal:  Front Bioeng Biotechnol       Date:  2022-03-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.