Literature DB >> 34362052

Comparison of Clinical Outcomes, Visual Quality and Visual Function of Two Presbyopia-Correcting Intraocular Lenses Made from the Same Material, but with Different Design and Optics.

Ladislav Viktor Nováček1,2, Marie Němcová1, Kateřina Tyx1, Kristýna Lahodová1, Leoš Rejmont2, Pavel Rozsíval1,3, Pavel Studený2.   

Abstract

This semi-prospective, parallel, comparative investigation evaluated the clinical outcomes and quality of vision (contrast sensitivity, visual function, dysphotopsia, spectacle use, overall satisfaction) after mono- or bilateral implantation of two presbyopia-correcting intraocular lenses (IOL)-the Liberty® 677MY or the AT LISA® tri 839M-in 50 eyes of 25 cataract patients. Clinical outcomes were assessed 3 and 12 months postoperatively. Eighty-nine percent of eyes implanted with the Liberty IOL and 59% of eyes implanted with the AT LISA IOL achieved a refractive outcome ±0.5 diopters of the target (emmetropia). Refractive outcomes were stable with both lenses. The proportions of eyes with 20/20 uncorrected distance visual acuity (UDVA) and 20/20 uncorrected near visual acuity (UNVA) were higher in the Liberty group than in the AT LISA group (UDVA: 56% vs. 41%; UNVA: 83% vs. 66%). Optical quality assessment results were comparable for the two IOLs. Superior photopic contrast sensitivity was found with the Liberty lens. The rate of Nd:YAG capsulotomy at the 12-month follow-up was 16.7% in the Liberty group and 40.6% for the AT LISA IOL. Considering that both lenses are made from the same material, we propose that the noted differences in clinical outcomes may derive from differences in design and optical surface between the two IOLs.

Entities:  

Keywords:  677MY; 839M; cataract; contrast sensitivity; dysphotopsia; multifocal intraocular lenses (MIOL); posterior capsule opacification; presbyopia; visual function; visual outcomes

Year:  2021        PMID: 34362052     DOI: 10.3390/jcm10153268

Source DB:  PubMed          Journal:  J Clin Med        ISSN: 2077-0383            Impact factor:   4.241


  2 in total

1.  Comparison of Anterior Capsule Polishing on the Rate of Neodymium: YAG Laser Capsulotomy After Two Multifocal Intraocular Lens Implantation.

Authors:  Lin Leng; Huiran Bai; Honglei Li; Dongle Liu; Yanfeng Han; Xiaoming Wu
Journal:  Front Med (Lausanne)       Date:  2022-03-10

2.  Simultaneous Presbyopia and Astigmatism Correction with a Novel Trifocal Toric Intraocular Lens-A One-Year Follow-Up.

Authors:  Ladislav Viktor Nováček; Marie Němcová; Kristýna Sičová; Kateřina Tyx; Pavel Rozsíval; Jan Němčanský; Pavel Studený
Journal:  J Clin Med       Date:  2022-07-19       Impact factor: 4.964

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.