Literature DB >> 34348753

Osteosynthesis of non-displaced femoral neck fractures in the elderly population using the femoral neck system (FNS): short-term clinical and radiological outcomes.

Oscar Vazquez1, Axel Gamulin2, Didier Hannouche2, Wilson Belaieff2.   

Abstract

BACKGROUND: Femoral neck fractures (FNF) are frequent in the elderly population, and surgical management is indicated in the vast majority of cases. Osteosynthesis is an alternative to arthroplasty for non-displaced FNF. Triple screw construct (TS) and the dynamic hip screw system (DHS) are considered gold standards for osteosynthesis. The newly available femoral neck system (FNS) currently lacks evidence as to whether it is a valid alternative to TS and DHS. The purpose of this study was to evaluate the short-term clinical and radiological outcomes after non-displaced (Garden I and II) FNF osteosynthesis using TS, DHS, and FNS.
METHODS: All the patients of the author's institution aged ≥ 75 years with a non-displaced (Garden I and II) FNF eligible for osteosynthesis between November 2015 and December 2019 were included in this single-center retrospective non-randomized study. Patients were treated with either TS, DHS, or FNS depending on the surgeon's preference. Clinical data (age, gender, ASA score, duration of surgery, need for blood transfusion and number of packed red blood cells transfused, surgical site complications, length of stay, discharge location, postoperative medical complications and readmission within 30 days, and mortality within 3 months) were extracted from the patients' charts. The radiological analysis assessed the fracture classification, fracture impaction, and proximal femur shortening at 3 and 6 months using the institutional imaging software.
RESULTS: Baseline characteristics in the TS (n = 32), DHS (n = 16), and FNS (n = 15) groups were similar with respect to age (mean 85 years), gender (female to male ratio 4:1), and ASA score. There were no significant differences across the groups for the need for blood transfusion, surgical site complications, length of stay, postoperative medical complications and readmission within 30 days, discharge location, and mortality within 3 months. The duration of surgery was significantly lower in the FNS group (43.3 vs 68.8 min; p < 0.001). The radiological assessment found similar impaction (5.2 mm ± 4.8) and shortening (8.6 mm ± 8.2) in all groups that did not seem to progress after 3 months.
CONCLUSION: The FNS appears to be a valid alternative implant for FNF osteosynthesis and is associated with a shorter operative time than TS and DHS. Short-term clinical and radiological outcomes of FNS are similar to TS and DHS implants. Further long-term multicenter randomized studies are however necessary to confirm these first results.
© 2021. The Author(s).

Entities:  

Keywords:  DHS; Dynamic hip screw; Elderly population; FNS; Femoral neck fracture; Femoral neck system; Orthogeriatrics; Osteosynthesis; Triple screws

Mesh:

Year:  2021        PMID: 34348753      PMCID: PMC8336369          DOI: 10.1186/s13018-021-02622-z

Source DB:  PubMed          Journal:  J Orthop Surg Res        ISSN: 1749-799X            Impact factor:   2.359


Background

Femoral neck fractures (FNF) are common in the elderly population and are associated with significant morbidity and mortality [1]. It is estimated that at the age of 80, the risk of developing a fracture of the proximal femur is approximately 20% for women and 10% for men [2]. Surgical management of FNF is indicated in the vast majority of elderly patients, and the indication to fix or to replace the fracture depends on fracture displacement and patient selection [3]. Elderly patients presenting with non-displaced (Garden I and II) FNF with a posterior tilt of > 20° and those with displaced (Garden III and IV) FNF will preferentially benefit from hip arthroplasty [4-6]. Stable non-displaced (Garden I and II) FNF may be managed with either hip arthroplasty or osteosynthesis [7], and the optimal treatment for such fractures is still subject to debate [6, 8]. Osteosynthesis is associated with higher complication rates than arthroplasty, such as non-union (20 to 35%) [9], avascular necrosis of the femoral head (23%) [10] fracture impaction, and consecutive abductor insufficiency (27%) [11]. This results in revision rates up to three times higher than with arthroplasty ranging from 10 to 49% [12, 13]. However, osteosynthesis has several advantages in this population, including a shorter operative time, less physiological stress [14], and reduced blood loss and risk of infection [15]. Immediate full weight-bearing is usually allowed, and low revision rates have been reported after non-displaced FNF fixation. The most commonly used implants for non-displaced FNF fixation are the triple screw construct (TS) and the dynamic hip screw system (DHS) [16]. The TS construct provides good torsional stability, preserves blood flow to the femoral head, and can be performed through a minimally invasive approach [17]. This technique, however, provides limited resistance to vertical shear forces at the fracture site [18]. The DHS design provides better resistance to vertical shear forces but requires a larger incision for implantation and bears a higher risk of avascular necrosis of the femoral head [19]. A large international, multicenter, randomized controlled trial failed to show any difference in terms of outcomes between TS and DHS [20]. The femoral neck system (FNS) is a novel device available since 2018 (https://www.jnjmedicaldevices.com/sites/default/files/user_uploaded_assets/pdf_assets/2019-11/118534-190712%20DSUS_EM%20). This system combines a short lateral plate that holds one or two locking screws with a fixed-angle tunnel allowing a diverging blade and screw construct to recoil through the plate. Biomechanical studies of this novel implant report high resistance to shear, torsion, and compression forces [21]. However, there is no in vivo literature available to date regarding this new device. Therefore, the aim of the present study was to assess the short-term radiological and clinical outcomes after non-displaced (Garden I and II) FNF using the FNS, in comparison with TS and DHS.

Methods

All patients > 75 years admitted between November 2015 and December 2019 with a non-displaced FNF (Garden I and II, posterior tilt < 20°) and eligible for fixation were included in this retrospective single-center non-randomized study. Patients are cared for by a multidisciplinary comanaged clinical pathway, and no major changes were brought to this setup during the study period, besides rotation of the team’s members within the division. Surgery was performed by four residents supervised by a consultant, and by 7 staff surgeons mitigating the effect of advanced trauma surgeon experience on operative time. All data were collected in the fracture registry available in our institution. All patients were allowed to fully bear weight with crutches or a walking frame after surgery. The following clinical data were extracted from patients’ charts: age, gender, ASA score, duration of surgery, need for blood transfusion and number of packed red blood cells transfused, surgical site complications (local or implant infection, peri-implant fracture, wound dehiscence), length of stay (LOS), discharge location, postoperative medical complications and readmission within 30 days, and mortality within 3 months. Standardized radiographic images were obtained preoperatively, postoperatively, and at 3 and 6 months after surgery, as per standard institutional protocol. Radiological analysis of proximal femur shortening was assessed according to Zhang et al. [22] and Felton et al. [11] (Fig. 1). Impaction was calculated by analysis of the displacement of the screw normalized to the length of the barrel for DHS and FNS (Figs. 2 and 3) and by measurement of the recoil of the screws normalized to screw length for TS (Fig. 4). All measurements were performed using a dedicated web-based open-source PACS workstation DICOM viewer (Weasis medical viewer, available on https://nroduit.github.io/en/). All data were anonymized and stored in a computerized database.
Fig. 1

Calculation of proximal femur shortening with DHS, TS, and FNS. Postoperative and 3-month X-ray

Fig. 2

Calculation of impaction with DHS implant. Postoperative and 3-month X-ray

Fig. 3

Calculation of impaction with FNS implant. Postoperative and 3-month X-ray

Fig. 4

Calculation of impaction with TS implant. Postoperative and 3-month X-ray

Calculation of proximal femur shortening with DHS, TS, and FNS. Postoperative and 3-month X-ray Calculation of impaction with DHS implant. Postoperative and 3-month X-ray Calculation of impaction with FNS implant. Postoperative and 3-month X-ray Calculation of impaction with TS implant. Postoperative and 3-month X-ray Categorical variables were expressed as proportion, and for continuous variables, mean, standard deviations, and ranges were reported. Patients’ characteristics and outcomes were compared between the groups (TS, DHS, FNS) using the chi-square test or Fisher exact test for qualitative parameters, and linear regression model for quantitative parameters, except for length of stay, which was compared between the groups using a Kruskal-Wallis test. Finally, the overall effect of surgery on radiographic outcomes was assessed using mixed effects linear regression models with random effect on patients and fixed effects on surgery and time, with no interaction term between fixed effects (i.e., we hypothesized that the effect of surgery, if any, was the same at 3 and 6 months). Statistical significance was assessed at the two-sided 0.05 level for all analyses. All analyses were performed using R version 4.0.2. This study was carried out in accordance with the Chart of Helsinki. This study followed the recommendations of the STROBE guidelines.

Results

Clinical outcomes

We analyzed 681 patients with FNF, of which 576 were displaced and 105 were non-displaced. Among non-displaced FNF, 42 were candidates for arthroplasty due to a posterior tilt > 20°, and 63 for osteosynthesis (Fig. 5). The latter were classified as Garden I and II in 54 and 9 cases, respectively. Fracture fixation was performed with TS, DHS, and FNS in 32, 16, and 15 patients, respectively. The 3 groups were comparable for age (TS 85, DHS 81; FNS 87, p = 0.48), gender (TS: female/male 28:4; DHS: female/male 10:6; FNS: female/male 13:2; p = 0.128), and ASA score (p = 0.726). The mean age for the TS, DHS, and FNS groups was 85.0, 83.4, and 86.1, respectively (Table 1).
Fig. 5

Flow chart showing the distribution of fractures by Fig implants

Table 1

Baseline characteristics

CharacteristicsModalityAll (n = 63)TS (n = 32)DHS (n = 16)FNS (n = 15)P value
Age (years)Mean (sd)84.9 (6.4)85 (6.6)83.4 (7.3)86.1 (4.6)0.48
Median (IQR)85 (79–90)85 (79.8–90)81 (77.8–88.8)87 (85–88.5)
Range75–10075–10076–9875–92
Missing0000
GenderFemale (n (%))51 (81)28 (88)10 (62)13 (86)0.128
Male (n (%))12 (19)4 (12)6 (36)2 (13)
ASA2 (n (%))20 (32)11 (34)6 (38)3 (20)0.726
3 (n (%))35 (56)18 (56)8 (50)9 (60)
4 (n (%))8 (12)3 (10)2 (12)3 (20)

TS triple screw, DHS dynamic hip screw system, FNS femoral neck system

Flow chart showing the distribution of fractures by Fig implants Baseline characteristics TS triple screw, DHS dynamic hip screw system, FNS femoral neck system The male to female ratio was 1:4. The average operative time for TS, DHS, and FNS was 66.9, 70.7, and 43.3 min, respectively. The FNS group showed a significantly shorter intraoperative time than TS and DHS (p < 0.001) (Table 2). The average LOS for TS, DHS, and FNS was 12.2 days (range 5–30), 12.4 (range 8–27), and 10.3 (range 5–25), respectively. The shorter LOS in the FNS group did not reach statistical significance. At least one blood transfusion was necessary in 3 patients in the TS group, none in the DHS group, and 1 in the FNS group. One single 30-day surgical postoperative complication was noted in the TS group warranting revision for infection. No early surgical revisions due to technical error or failure of the implant were noted. Thirty-seven percent of all patients developed at least one medical complication within 30 days after surgery. These were noted in 14 (43%), 4 (24%), and 5 (26%) patients of the TS, DHS, and FNS groups, respectively, without reaching statistical significance. Overall, patient discharge was possible to a rehabilitation center, nursing facility, and home in 63%, 25%, and 11% cases, respectively. Transfer to a rehabilitation center was noted in 20, 11, and 9 patients in the TS, DHS, and FNS groups, respectively. One case from the FNS group required hospital readmission at 30 days, due to an acute onset pulmonary edema. The overall 3-month mortality was 8%, divided in 3 patients for the TS group, 2 patients for the DHS group, and 0 patients for the FNS group.
Table 2

Clinical outcomes

CharacteristicsModalityAll (n = 63)TS (n = 32)DHS (n = 16)FNS (n = 15)P value
Duration of surgery (min)Mean (sd)62.2 (23.6)66.9 (25.4)70.7 (20)43.3 (10.1)< 0.001
Median (IQR)55 (46–76)63.5 (50–80)66 (53–83)42 (37.5–52.5)
Range20–12820–12850–11428–63
Missing0000
Blood transfusion (n (%))059 (94)29 (90)16 (100)14 (93)0.466
12 (3.2)2 (6.3)
22 (3.2)1 (3.1)1 (6.7)
Surgical site complications (n (%))062 (98)31 (97)16 (100)15 (100)1
11 (1.6)1 (3,1)
Length of stay (days)Mean (sd)11.8 (5.9)12.2 (6.2)12.4 (5.3)10.3 (6)0.131
Median (IQR)10 (8–13.5)10 (8–15)10.5 (9–13.2)8 (6–10.5)
Range5–305–308–275–25
Missing0000
Discharge location (n (%))Rehabilitation40 (63)20 (63)11 (69)9 (60)0.509
Home7 (11)2 (6)3 (19)2 (13)
Nursing home16 (2)10 (31)2 (13)4 (27)
Medical complication (30 days) (n(%))040 (63)18 (56)12 (75)10 (67)0.441
17 (11)4 (13)1 (6)2 (13)
211 (17)7 (22)2 (13)2 (13)
32 (3)1 (3)1 (6)
42 (3)1 (3)1 (6.7)
51 (2)1 (3)
Readmissions (30 days) (n (%))11 (2)1 (6.7)0.238
062 (98)32 (100)16 (100)14 (93)
Death (3 months)15320.585
058291415

Surgical site complications include local or implant infection, peri-implant fracture, and wound dehiscence. Medical complications include heart failure, respiratory failure, urinary tract infection, and pulmonary embolism

TS triple screw, DHS dynamic hip screw system, FNS femoral neck system

Clinical outcomes Surgical site complications include local or implant infection, peri-implant fracture, and wound dehiscence. Medical complications include heart failure, respiratory failure, urinary tract infection, and pulmonary embolism TS triple screw, DHS dynamic hip screw system, FNS femoral neck system

Radiographic outcomes

In our study population, 15 patients (24%) did not have any documented radiological follow-up, 13 (20%) had 1 3-month X-ray, and 35 (56%) had both 3- and 6-month X-ray. Reasons for incomplete radiological follow-up were due to living abroad (4), death (5), refusal (1), and inability (18) to attend postoperative consultations. Radiographic analysis showed an average of 5.2 ± 4.8 mm fracture impaction at 3 months when compared to immediate postoperative X-rays. The TS, DHS, and FNS groups showed a similar mean impaction of 5.0 ± 4.5, 5.4 ± 6, and 5.5mm ± 4.4, respectively. In mixed linear regression model, the type of surgery had no statistically significant effect on impaction (p = 0.872) and impaction was not statistically significantly different between 3 and 6 months (p = 0.979). Analysis of proximal femur shortening at 3 months showed an average 8.6-mm ascension of the trochanter with respect to the acetabular roof. The TS, DHS, and FNS groups had an 8.4 ± 7.0, 8.3 ± 11.9, and 9.3mm ± 6.0 shortening, respectively. In the mixed linear regression model, the type of surgery had no statistically significant effect on shortening (p = 0.982), and shortening was not statistically significantly different between 3 and 6 months (p = 0.218) (Table 3).
Table 3

Impaction and shortening at 3 and 6 months

CharacteristicsModalityAll (n = 63)TS (n = 32)DHS (n = 16)FNS (n = 15)P value
Impaction
 3 monthsMean (sd)5.2 (4.8)5 (4.5)5.4 (6)5.5 (4.4)
Median (IQR)4.9 (1.7–7.2)4.9 (2.5–6.6)2.6 (1.4–7.7)5.4 (1.8–9.4)
Range0–21.10–180.2–21.10.2–13.1
Missing151032
 6 monthsMean (sd)5.4 (5.2)5.4 (4.8)5.6 (5.9)5 (6.7)
Median (IQR)4.7 (2.6–6.9)4.7 (3.2–5.9)4.5 (2–8.1)7.3 (3.4–8.9)
Range− 4.8–19.60–19.6− 2.9–18.7− 4.8–10.1
Missing3013611
 Global0.872
 Δ 3–6 months0.979
Shortening
 3 monthsMean (sd)8.6 (8.2)8.4 (7.0)8.3 (11.9)9.3 (6.0)
Median (IQR)8.3 (2.4–12.1)8.6 (4.3–12.6)8.4 (0.3–11.4)8.3 (5.7–13.3)
Range− 6.2–42− 6.2–22.3− 4.1–421.1–22
Missing151032
 6 monthsMean (sd)7.0 (9.0)8.1 (10.3)4.9 (7.9)6.7 (4.0)
Median (IQR)6 (1.2–10.5)5 (2.5–11.4)6.7 (− 2.3–12.4)7.8 (4.9–9.6)
Range− 5.8–38.9− 3.9–38.9− 5.8–13.61.2–10.1
Missing3013611
 Global0.982
 Δ 3–6 months0.218

TS triple screw, DHS dynamic hip screw system, FNS femoral neck system

Impaction and shortening at 3 and 6 months TS triple screw, DHS dynamic hip screw system, FNS femoral neck system

Discussion

Fixation options for non-displaced FNF in the elderly population are associated with several advantages such as reduction in operative time and reduced blood loss in comparison with hip replacement surgery. To date, no implant has been proven superior to another for FNF osteosynthesis [20, 23]. The FNS is a novel implant designed to address the low resistance to shearing forces of TS and allow better rotational stability than the DHS. To the best of the authors’ knowledge, no studies to date have evaluated the clinical and radiological outcomes of the FNS. Operative time is an important factor when considering surgery in frail patients. Longer surgeries are associated with higher blood loss, longer anesthesia, higher infection rates, and overall higher postoperative complication rates [24]. Our study found a significantly shorter operative time in the FNS group, with an average of 43.3 min (vs. 66.9 min). Eleven different surgeons (seven staff surgeons and four residents under supervision) have implanted the FNS, and none had experience with this implant before the start of the study. Also, none of them has implanted the FNS more than 2 times. This finding highlights the relative simplicity of the FNS technique, despite a theoretical learning curve for this novel implant. Anemia is a negative predictive factor for survival after hip fracture surgery [25]. As for TS and to a lesser extent the DHS, the FNS is designed to be implanted through a minimally invasive approach using a single lateral small-sized 2–3-cm incision. Our study failed to identify any significant postoperative differences in the need for transfusion between the groups, despite a theoretical larger incision and soft tissue trauma associated with DHS. Moreover, it is possible that preoperative bleeding from the fracture site, regardless of the time to surgery, maybe a confounding factor in the occurrence of postoperative anemia. Our study did however not directly assess absolute hemoglobin values pre- and postoperatively. In light of the budgetary constraints and the economic burden of fragility fractures, LOS is a much looked upon variable to measure the quality of care and efficiency. The average in-hospital stay in the study’s population was 11.8 days. This is less than the LOS of patients with arthroplasties for FNF (12.8 days, authors’ institutional Elderly Proximal Femoral Fracture Register, unpublished data). Our study suggests a trend toward a shorter stay in the FNS group (10.4 days) without reaching statistical significance. This potential shorter stay associated with FNS may be beneficial in terms of resources available on the wards and lowering the burden on healthcare professionals in charge of this highly dependent patient population. Femoral neck fractures frequently result in an important loss of function despite appropriate rehabilitation. One of the reasons for this is the occurrence of a limp, with or without leg length discrepancy. Functional shortening of the femoral neck due to fracture impaction may result in the loss of the abductors’ moment of force on the greater trochanter, resulting in weakness, pain, and patient dissatisfaction [11]. In this study, TS, DHS, and FNS were associated with some degree of radiologic femoral neck impaction and proximal femur shortening during follow-up. However, none of the implants was significantly more prone to do so. From that perspective, despite our small group of patients, the FNS seems to be at least as effective as other implants in maintaining a stable fracture reduction. It is also important to acknowledge that, in contrast to TS and DHS, some technical inaccuracies in choice of size and positioning of the implants due to a lack of experience with this new implant may have negatively influenced our outcomes. Despite this, no patient in the FNS group needed revision surgery due to technical error. This study has several limitations. First, it may be subject to methodological bias due to its retrospective and observational design. Secondly, clinical and radiological outcomes were reported with a low number of patients. This is due to the fact that non-displaced FNF are fairly uncommon as they represent 15% of all FNF (authors’ institutional Elderly Proximal Femoral Fracture Register, unpublished data). A larger scale study, possibly multicenter, would be desirable to confirm our preliminary results. Also, the FNS has only been recently made available in the authors’ institution, providing fewer cases than TS or DHS to include in the analysis. Third, 24% of the patients were lost to follow-up in the current series, but this is in the range of most studies on FNFs in elderly patients. In a multicenter randomized trial on 201 patients comparing cemented and uncemented hemiarthroplasty, and Moerman and al. found a similar 24% rate of loss to follow-up, which was mainly due to a high number of patients with cognitive disorders and high age of the participators who were unable to adhere to postoperative follow-up visits [26]. Fourth, our study was focused on short-term outcomes, and hypothesized that most adverse events correlated with the use of the device (FNS, DHS, or triple screws), would occur within 6 months after surgery. A long-term follow-up would be useful in detecting delayed complications such as AVN, as well as hardware-related trochanteric pain. Fifth, we acknowledge that fracture healing evaluation with a CT scan would have been more accurate to detect non-union, but this is not performed routinely in our department, neither in most studies published on this topic. In a recent study evaluating the outcomes of intracapsular non-displaced FNFs in 244 patients treated with cannulated screws, mechanical failure of fixation was identified on standard X-rays, which is considered as the standard of care in this elderly population [27]. Lastly, this study was not designed to evaluate the clinical correlation between the secondary displacement of the fracture and clinical or gait abnormalities.

Conclusion

To the best of the authors’ knowledge, this is the first study to evaluate the clinical and radiological outcomes of the FNS. In comparison with TS and DHS, the use of the FNS is potentially associated with a significantly shorter operative time and appears to be as effective as TS and DHS in preventing early secondary fracture displacement. The FNS appears to be a valid alternative to other FNF fixation techniques in non-displaced FNF in the elderly population. Further high-quality, large volume, long-term multicenter randomized studies are necessary to confirm these first results.
  25 in total

1.  Long-term risk of osteoporotic fracture in Malmö.

Authors:  J A Kanis; O Johnell; A Oden; I Sembo; I Redlund-Johnell; A Dawson; C De Laet; B Jonsson
Journal:  Osteoporos Int       Date:  2000       Impact factor: 4.507

2.  Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial.

Authors: 
Journal:  Lancet       Date:  2017-03-03       Impact factor: 79.321

3.  Vertical shear fractures of the femoral neck. A biomechanical study.

Authors:  A C Baitner; S G Maurer; D G Hickey; L M Jazrawi; F J Kummer; J Jamal; S Goldman; K J Koval
Journal:  Clin Orthop Relat Res       Date:  1999-10       Impact factor: 4.176

4.  A new angle and its relationship with early fixation failure of femoral neck fractures treated with three cannulated compression screws.

Authors:  Y L Zhang; W Zhang; C Q Zhang
Journal:  Orthop Traumatol Surg Res       Date:  2017-01-16       Impact factor: 2.256

5.  Hemiarthroplasty or internal fixation for intracapsular displaced femoral neck fractures: randomised controlled trial.

Authors:  Frede Frihagen; Lars Nordsletten; Jan Erik Madsen
Journal:  BMJ       Date:  2007-12-04

6.  Not All Garden-I and II Femoral Neck Fractures in the Elderly Should Be Fixed: Effect of Posterior Tilt on Rates of Subsequent Arthroplasty.

Authors:  Kanu Okike; Ugochukwu N Udogwu; Marckenley Isaac; Sheila Sprague; Marc F Swiontkowski; Mohit Bhandari; Gerard P Slobogean
Journal:  J Bone Joint Surg Am       Date:  2019-10-16       Impact factor: 5.284

Review 7.  A systematic review of undisplaced femoral neck fracture treatments for patients over 65 years of age, with a focus on union rates and avascular necrosis.

Authors:  Dan-Feng Xu; Fang-Gang Bi; Chi-Yuan Ma; Zheng-Fa Wen; Xun-Zi Cai
Journal:  J Orthop Surg Res       Date:  2017-02-10       Impact factor: 2.359

8.  Comparison of three different internal fixation implants in treatment of femoral neck fracture-a finite element analysis.

Authors:  Jia Li; Zhe Zhao; Pengbin Yin; Licheng Zhang; Peifu Tang
Journal:  J Orthop Surg Res       Date:  2019-03-12       Impact factor: 2.359

9.  More complications in uncemented compared to cemented hemiarthroplasty for displaced femoral neck fractures: a randomized controlled trial of 201 patients, with one year follow-up.

Authors:  Sophie Moerman; Nina M C Mathijssen; Dieu D Niesten; Roeland Riedijk; Willard J Rijnberg; Sander Koëter; Keetie Kremers van de Hei; Wim E Tuinebreijer; Tim L Molenaar; Rob G H H Nelissen; Anne J H Vochteloo
Journal:  BMC Musculoskelet Disord       Date:  2017-04-21       Impact factor: 2.362

10.  Factors that influence the complications and outcomes of femoral neck fractures treated by cannulated screw fixation.

Authors:  Nikolai Ramadanov; Ionel Toma; Harald Herkner; Roman Klein; Wilhelm Behringer; Gerrit Matthes
Journal:  Sci Rep       Date:  2020-01-20       Impact factor: 4.379

View more
  5 in total

Review 1.  Surgical treatment options for femoral neck fractures in the elderly.

Authors:  Boris A Zelle; Luis M Salazar; Shain L Howard; Kisan Parikh; Hans-Christoph Pape
Journal:  Int Orthop       Date:  2022-02-21       Impact factor: 3.075

2.  Femoral neck system reduces surgical time and complications in adults with femoral neck fractures: A systematic review and meta-analysis.

Authors:  Ahmed Saad; Mohit Kumar Patralekh; Vijay Kumar Jain; Sagaurav Shrestha; Rajesh Botchu; Karthikeyan P Iyengar
Journal:  J Clin Orthop Trauma       Date:  2022-06-11

3.  Comparison Between Femoral Neck Systems and Cannulated Cancellous Screws in Treating Femoral Neck Fractures: A Meta-Analysis.

Authors:  Peng Tian; Lan Kuang; Zhi-Jun Li; Gui-Jun Xu; Xin Fu
Journal:  Geriatr Orthop Surg Rehabil       Date:  2022-07-06

Review 4.  Neck of femur fractures treated with the femoral neck system: outcomes of one hundred and two patients and literature review.

Authors:  Amit Davidson; Shlomo Blum; Elad Harats; Erick Kachko; Ahmad Essa; Ram Efraty; Amos Peyser; Peter V Giannoudis
Journal:  Int Orthop       Date:  2022-05-11       Impact factor: 3.479

5.  Comparing Perioperative Outcome Measures of the Dynamic Hip Screw and the Femoral Neck System.

Authors:  Marcel Niemann; Karl F Braun; Sufian S Ahmad; Ulrich Stöckle; Sven Märdian; Frank Graef
Journal:  Medicina (Kaunas)       Date:  2022-02-26       Impact factor: 2.430

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.