Abstract
BACKGROUND: Anaphylaxis caused by a catheter itself used for endovascular surgery is rare, and a method for detection of a causative catheter has not been established. We report a case of catheter-induced anaphylaxis in which the causative catheter was successfully detected. CASEEntities:
Keywords: Anaphylaxis; Basophil activation test; Catheter; Kounis syndrome; Neuroendovascular surgery
Year: 2021 PMID: 34333727 PMCID: PMC8325728 DOI: 10.1186/s40981-021-00463-7
Source DB: PubMed Journal: JA Clin Rep ISSN: 2363-9024
Fig. 1Clinical course and identification of the causative agent of anaphylaxis. a Anesthetic chart during neuroendovascular surgery. b ST segment elevation after onset of hypotension. FiO2 fraction of inspiratory oxygen, SpO2 percutaneous oxygen saturation, HR heart rate, bpm beats per minute, ABP arterial blood pressure, EtcO2 endo-tidal carbon dioxide, CAG coronary angiography
Drugs and materials of medical equipment used during neuroendovascular surgery and previous diagnostic angiography
| 1. | Propofol |
| 2. | Fentanyl |
| 3. | Remifentanil |
| 4. | Rocuronium |
| 5. | Cefazolin |
| 6. | Iohexol |
| 7. | Heparin |
| 1. Urinary catheter kit | Urinary catheter |
| 2. | Glove |
| 3. | Jerry |
| 4. | Benzalkonium chloride |
| 5. | Olanexidine gluconate |
| 6. Antiseptic | Chlorhexidine |
| 7. Glove | Latex |
| 1. Guiding catheter | Maleic anhydride |
| 2. Stiff wire guide | Polytetrafluoroethylene |
| 3. Guide wire | Polyvinyl pyrrolidone |
| 4. Sheath kit (sheath) | Maleic anhydride |
| 5. Sheath kit (accessory 1) | Maleic anhydride |
| 6. Sheath kit (accessory 2) | Non-coating |
| 7. Guiding catheter | Maleic anhydride |
| 8. Guide wire | Polyvinyl pyrrolidone |
| 9. Microcatheter | Hyaluronic acid product |
| 10. Microcatheter | Polyacrylamide/polyvinyl pyrrolidone |
| 1. Guide wire | Maleic anhydride |
| 2. Sheath kit | Non-coating |
| 3. Guiding catheter | Maleic anhydride |
Fig. 2Basophil activation test. The basophil population (side scatter low CD3 − CRTH2 + cells) is shown, and the numbers represent the percentages of activated basophils