| Literature DB >> 34332561 |
Won Jong Choi1, Yeonji Jang2, Seong-Joon Kim1, Jae Ho Jung3.
Abstract
BACKGROUND: This study aimed to present a simple method for evaluating transient eye closure (TEC) evoked by bright light and find the agreement between TEC and photosensitivity. We also assessed the associated factors with TEC in the patients with intermittent exotropia (IXT).Entities:
Keywords: Eye closure; Intermittent exotropia; Photophobia; Photosensitivity; Squint
Mesh:
Year: 2021 PMID: 34332561 PMCID: PMC8325830 DOI: 10.1186/s12886-021-02046-7
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1We captured snapshots of reflexive eye closure and pupil changes from a live video feed using a near-infrared vision monitoring system (Mon CV3, Metrovision, France) under different light intensities. Scotopic phase (darkness) for 3300 ms, mesopic phase (under room light without light stimulation) for 200 ms, scotopic phase for 3300 ms, low-intensity white light phase (10 cd/m2) for 200 ms, scotopic phase for 3300 ms, and high-intensity white light phase (100 cd/m2) for 200 ms.
Association between clinical characteristics and transient eye closure (TEC) in intermittent exotropia patients
| Overall | Transient eye closure (+) | Transient eye closure (−) | Multivariate analysis | ||
|---|---|---|---|---|---|
| Onset of IXT (years,mean ± SD) | 4.13 ± 2.13 | 4.07 ± 1.94 | 4.18 ± 2.29 | 0.85 | 0.11 |
| Photo-sensitivity | |||||
| Yes | 29 (47.5%) | 23 (74.1%) | 6 (26.5%) | < 0.01a | < 0.01a |
| No | 32 (52.5%) | 4 (25.9%) | 28 (73.5%) | ||
| Distance angle (PD,mean ± SD) | 26.15 ± 6.39 | 24.41 ± 7.29 | 27.53 ± 5.28 | 0.06 | 0.99 |
| Near angle (PD, mean ± SD) | 24.67 ± 7.38 | 22.37 ± 7.87 | 26.50 ± 6.51 | 0.03a | 0.10 |
| Control scale | |||||
| 0 ~ 2 (good-control) | 49 (80.3%) | 21 (77.8%) | 28 (82.4%) | 0.66 | 0.39 |
| 3 ~ 5 (poor-control) | 12 (19.7%) | 6 (22.2%) | 6 (17.6%) | ||
| Distance W4D | |||||
| Normal | 32 (56.1%) | 20 (76.9%) | 12 (38.7%) | < 0.01a | 0.02a |
| Abnormal | 25 (43.9%) | 6 (23.1%) | 19 (61.3%) | ||
| Near W4D | |||||
| Normal | 43 (75.4%) | 21 (80.8%) | 22 (71.0%) | 0.39 | 0.26 |
| Abnormal | 14 (24.6%) | 5 (19.2%) | 9 (29.0%) | ||
| Near stereoacuity (arcsec, mean ± SD) | 63.65 ± 75.32 | 75.42 ± 103.51 | 53.77 ± 37.95 | 0.32 | 0.17 |
astatistical significance, W4D Worth 4 dot test, SD Standard deviation
Pupil dynamics and transient eye closure (TEC) using a near infrared vision monitoring system
| Dynamics of pupil | Transient eye closure (−) | Transient eye closure (+) | ||
|---|---|---|---|---|
| Initial diameter (mm) | R | 5.26 (±0.81) | 5.71 (±0.27) | 0.14 |
| L | 5.35 (±0.71) | 5.69 (±0.22) | 0.18 | |
| Amplitude of contraction (mm) | R | 1.96 (±0.30) | 2.21 (±0.30) | 0.90 |
| L | 2.09 (±0.24) | 2.18 (±0.27) | 0.41 | |
| Latency of contraction (ms) | R | 193.6 (±35.47) | 198.3 (±74.15) | 0.85 |
| L | 191.0 (±35.81) | 202.3 (±75.45) | 0.66 | |
| Duration of contraction (ms) | R | 642.9 (±65.47) | 651.2 (±108.44) | 0.83 |
| L | 681.6 (±84.35) | 670.3 (±87.74) | 0.76 | |
| Velocity of contraction (mm/s) | R | 6.98 (±1.96) | 7.33 (±1.32) | 0.63 |
| L | 7.20 (±1.05) | 7.77 (±2.51) | 0.50 | |
| Latency of dilation (ms) | R | 836.5 (±78.86) | 849.5 (±54.80) | 0.66 |
| L | 881.6 (±72.72) | 862.8 (±65.91) | 0.53 | |
| Duration of dilation (ms) | R | 1630.9 (±72.72) | 1624.5 (±58.06) | 0.82 |
| L | 1586.2 (±79.82) | 1624.7 (±44.37) | 0.20 | |
| Velocity of dilation (mm/s) | R | 2.63 (±1.10) | 3.00 (±0.80) | 0.38 |
| L | 2.52 (±0.59) | 3.00 (±0.70) | 0.13 | |
R Right eye, L Left eye, SD Standard deviation