Literature DB >> 34331607

Predictive performance of dynamic arterial elastance for arterial pressure response to fluid expansion in mechanically ventilated hypotensive adults: a systematic review and meta-analysis of observational studies.

Xiaoyang Zhou1,2, Weihao Pan3, Bixin Chen1,2, Zhaojun Xu1,2, Jianneng Pan4,5.   

Abstract

BACKGROUND: Dynamic arterial elastance (Eadyn) has been extensively considered as a functional parameter of arterial load. However, conflicting evidence has been obtained on the ability of Eadyn to predict mean arterial pressure (MAP) changes after fluid expansion. This meta-analysis sought to assess the predictive performance of Eadyn for the MAP response to fluid expansion in mechanically ventilated hypotensive patients.
METHODS: We systematically searched electronic databases through November 28, 2020, to retrieve studies that evaluated the association between Eadyn and fluid expansion-induced MAP increases in mechanically ventilated hypotensive adults. Given the diverse threshold value of Eadyn among the studies, we only reported the area under the hierarchical summary receiver operating characteristic curve (AUHSROC) as the primary measure of diagnostic accuracy.
RESULTS: Eight observational studies that included 323 patients with 361 fluid expansions met the eligibility criteria. The results showed that Eadyn was a good predictor of MAP increases in response to fluid expansion, with an AUHSROC of 0.92 [95% confidence interval (CI) 0.89 to 0.94]. Six studies reported the cut-off value of Eadyn, which ranged from 0.65 to 0.89. The cut-off value of Eadyn was nearly conically symmetrical, most data were centred between 0.7 and 0.8, and the mean and median values were 0.77 and 0.75, respectively. The subgroup analyses indicated that the AUHSROC was slightly higher in the intensive care unit (ICU) patients (0.96; 95% CI 0.94 to 0.98) but lower in the surgical patients in the operating room (0.72; 95% CI 0.67 to 0.75). The results indicated that the fluid type and measurement technique might not affect the diagnostic accuracy of Eadyn. Moreover, the AUHSROC for the sensitivity analysis of prospective studies was comparable to that in the primary analysis.
CONCLUSIONS: Eadyn exhibits good performance for predicting MAP increases in response to fluid expansion in mechanically ventilated hypotensive adults, especially in the ICU setting.
© 2021. The Author(s).

Entities:  

Keywords:  Arterial load; Diagnostic test accuracy; Dynamic arterial elastance; Fluid expansion; Hypotension

Year:  2021        PMID: 34331607     DOI: 10.1186/s13613-021-00909-2

Source DB:  PubMed          Journal:  Ann Intensive Care        ISSN: 2110-5820            Impact factor:   6.925


  2 in total

1.  [Value of dynamic arterial elastance in the predication of arterial pressure response to volume loading in shock patients].

Authors:  Mao-lei Gong; Da-wei Liu; Xiao-ting Wang; Xiu-kai Chen
Journal:  Zhonghua Yi Xue Za Zhi       Date:  2013-05-07

2.  Left ventricular interaction with arterial load studied in isolated canine ventricle.

Authors:  K Sunagawa; W L Maughan; D Burkhoff; K Sagawa
Journal:  Am J Physiol       Date:  1983-11
  2 in total
  2 in total

1.  The ROX index as a predictor of high-flow nasal cannula outcome in pneumonia patients with acute hypoxemic respiratory failure: a systematic review and meta-analysis.

Authors:  Xiaoyang Zhou; Jiequan Liu; Jianneng Pan; Zhaojun Xu; Jianfei Xu
Journal:  BMC Pulm Med       Date:  2022-04-01       Impact factor: 3.317

2.  Arterial Hypotension Following Norepinephrine Decrease in Septic Shock Patients Is Not Related to Preload Dependence: A Prospective, Observational Cohort Study.

Authors:  Stefan Andrei; Maxime Nguyen; Osama Abou-Arab; Belaid Bouhemad; Pierre-Grégoire Guinot
Journal:  Front Med (Lausanne)       Date:  2022-02-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.