Literature DB >> 34329416

Total aortic arch replacement using the J-graft open stent graft for distal aortic arch aneurysm: report from two centres in Japan.

Koji Tsutsumi1, Osamu Ishida1, Nozomu Yamanaka1, Kanako Hayashi2, Kenichi Hashizume2.   

Abstract

OBJECTIVES: The open-style stent graft technique has been changing the strategy for true distal arch aneurysms extending to the descending aorta. Our mid-term results of surgical repair using a J-graft open stent graft are presented.
METHODS: Between May 2015 and June 2020, 69 patients with a distal arch aneurysm (53 males, median age 74 years) underwent total arch replacement combined with J-graft open stent deployment. All 59 surviving patients were followed for a median follow-up period of 1.8 (0.6-3.6) years.
RESULTS: Antegrade deployment was successfully performed in all patients without any difficulties. The deployed device was securely fixed at the target area, and it initiated thrombus formation. The diameter of the excluded aneurysm was decreased in 54 patients (91.5%) during the follow-up period. There were no type I endoleaks, but there were 3 type II endoleaks; 2 of the 3 type II endoleaks disappeared during the follow-up period. Additional endovascular operations were performed in 3 patients. There were 10 in-hospital deaths (14.5%), and the incidences of stroke, spinal cord injury and distal embolism were 11.6%, 5.8% and 2.9%, respectively. The 1- and 3-year survival rates were 84.8% and 79.4%, respectively, and the 1- and 3-year freedom from reintervention rates were 97.2% and 81.3%, respectively.
CONCLUSIONS: The J-graft open stent graft was easy to deploy, and it could shift the distal anastomosis to a more proximal side. The mid-term performance of this device was good. It has the potential to provide one-stage repair.
© The Author(s) 2021. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Open stent graft; Total arch replacement; True distal arch aneurysm

Mesh:

Year:  2021        PMID: 34329416      PMCID: PMC8686013          DOI: 10.1093/icvts/ivab114

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  14 in total

1.  Multicenter early experience with extended aortic repair in acute aortic dissection: is simultaneous descending stent grafting justified?

Authors:  Konstantinos Tsagakis; Davide Pacini; Roberto Di Bartolomeo; Michael Gorlitzer; Gabriel Weiss; Martin Grabenwoger; Carlos A Mestres; Jaroslav Benedik; Stepan Cerny; Heinz Jakob
Journal:  J Thorac Cardiovasc Surg       Date:  2010-12       Impact factor: 5.209

Review 2.  Current status and recommendations for use of the frozen elephant trunk technique: a position paper by the Vascular Domain of EACTS.

Authors:  Malakh Shrestha; Jean Bachet; Joseph Bavaria; Thierry P Carrel; Ruggero De Paulis; Roberto Di Bartolomeo; Christian D Etz; Martin Grabenwöger; Michael Grimm; Axel Haverich; Heinz Jakob; Andreas Martens; Carlos A Mestres; Davide Pacini; Tim Resch; Marc Schepens; Paul P Urbanski; Martin Czerny
Journal:  Eur J Cardiothorac Surg       Date:  2015-03-13       Impact factor: 4.191

Review 3.  Editorial comment regarding "Total aortic arch replacement using the frozen elephant trunk technique with J Graft Open Stent Graft for distal aortic arch aneurysm".

Authors:  Kazuo Yamanaka
Journal:  Gen Thorac Cardiovasc Surg       Date:  2018-07-23

4.  Aortic remodeling with frozen elephant trunk technique for Stanford type A aortic dissection using Japanese J-graft open stent graft.

Authors:  Masato Tochii; Yoshiyuki Takami; Hiroshi Ishikawa; Michiko Ishida; Yoshiro Higuchi; Yusuke Sakurai; Kentaro Amano; Yasushi Takagi
Journal:  Heart Vessels       Date:  2018-09-06       Impact factor: 2.037

5.  Stented elephant trunk procedure combined with ascending aorta and arch replacement for acute type A aortic dissection.

Authors:  Tomohiro Mizuno; Masaaki Toyama; Noriyuki Tabuchi; Haison Wu; Makoto Sunamori
Journal:  Eur J Cardiothorac Surg       Date:  2002-10       Impact factor: 4.191

6.  A new device as an open stent graft for extended aortic repair: a multicentre early experience in Japan.

Authors:  Naomichi Uchida; Akira Katayama; Shinichi Higashiue; Motomi Shiono; Mitsumasa Hata; Kazutomo Minami; Kazuo Yamanaka; Shinji Miyamoto; Yoshiki Sawa; Toru Kuratani; Masaaki Kato
Journal:  Eur J Cardiothorac Surg       Date:  2015-09-18       Impact factor: 4.191

7.  Total aortic arch replacement through the L-incision approach.

Authors:  Ryuji Tominaga; Kazuhiro Kurisu; Yoshie Ochiai; Atsuhiro Nakashima; Munetaka Masuda; Shigeki Morita; Hisataka Yasui
Journal:  Ann Thorac Surg       Date:  2003-01       Impact factor: 4.330

8.  Total aortic arch replacement using frozen elephant trunk technique with J Graft Open Stent Graft for distal aortic arch aneurysm.

Authors:  Shigeki Koizumi; Atsushi Nagasawa; Tadaaki Koyama
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-11-08

9.  Investigation of the freely available easy-to-use software 'EZR' for medical statistics.

Authors:  Y Kanda
Journal:  Bone Marrow Transplant       Date:  2012-12-03       Impact factor: 5.483

10.  One-stage repair in complex multisegmental thoracic aneurysmal disease: results of a multicentre study.

Authors:  Carlos-A Mestres; Konstantinos Tsagakis; Davide Pacini; Roberto Di Bartolomeo; Martin Grabenwöger; Michael Borger; Robert S Bonser; Heinz Jakob
Journal:  Eur J Cardiothorac Surg       Date:  2013-08-04       Impact factor: 4.191

View more
  1 in total

1.  Risk factors for stroke after total aortic arch replacement using the frozen elephant trunk technique.

Authors:  Tim Berger; Maximilian Kreibich; Felix Mueller; Lara Breurer-Kellner; Bartosz Rylski; Stoyan Kondov; Holger Schröfel; Clarence Pingpoh; Friedhelm Beyersdorf; Matthias Siepe; Martin Czerny
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-05-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.