| Literature DB >> 34327228 |
Sally A Mahmoud1, Subhashini Ganesan2, Esra Ibrahim1, Bhagyashree Thakre1, Juliet G Teddy1, Preety Raheja1, Walid Z Abbas2.
Abstract
In this COVID-19 pandemic, there is a dire need for cost-effective and less time-consuming alternatives for SARS-CoV-2 testing. The RNA extraction-free method for detecting SARS-CoV-2 in saliva is a promising option. This study found that it has high sensitivity (85.34%), specificity (95.04%), and was comparable to the gold standard nasopharyngeal swab (NPS) sample tests. The method showed good agreement between salivary and NPS samples, with a kappa coefficient of 0.797. However, there are variations in the sensitivity and specificity based on the RT-PCR kit used. The Thermo Fisher Applied Biosystems showed high sensitivity, positive predictive value (PPV), and negative predictive value (NPV) but also showed a higher percentage of invalid reports. On the other hand, the BGI kit showed high specificity, better agreement (kappa coefficient) between the results of saliva and NPS samples, and higher correlation between the Ct values of saliva and NPS samples. Thus, the RNA extraction-free method for salivary sample serves as an effective alternative screening method for COVID-19.Entities:
Mesh:
Substances:
Year: 2021 PMID: 34327228 PMCID: PMC8245243 DOI: 10.1155/2021/5568350
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Figure 1Process of RNA extraction-free method for molecular testing of SARS-CoV-2.
Comparison of results of salivary sample with the results of standard NPS using the BGI RT-PCR kit (n = 595).
| NPS sample (BGI kit) | Positive | Negative | Total | |
|---|---|---|---|---|
| RNA extraction-free method for saliva (BGI kit) | Positive | 198 | 18 | 216 |
| Negative | 34 | 345 | 379 | |
| Total | 232 | 363 | 595 | |
Comparison of results of salivary sample with the results of standard NPS using the Thermo Fisher RT-PCR kit (n = 231).
| NPS sample (Thermo Fisher Applied Biosystems kit) | Positive | Negative | Total | |
|---|---|---|---|---|
| RNA extraction-free method for saliva (Thermo Fisher Applied Biosystems kit) | Positive | 200 | 3 | 203 |
| Negative | 2 | 26 | 28 | |
| Total | 202 | 29 | 231 | |
Comparison of the matched salivary samples processed through the BGI kit with the gold standard NPS results (n = 254).
| NPS sample (BGI kit) | Positive | Negative | Total | |
|---|---|---|---|---|
| RNA extraction-free method for saliva (BGI kit) | Positive | 109 | 10 | 119 |
| Negative | 19 | 116 | 135 | |
| Total | 128 | 126 | 254 | |
Compares the parameters between the BGI and Thermo Fisher kit.
| Parameters | RNA extraction-free direct method (BGI) | RNA extraction-free direct method (Thermo) |
|
|---|---|---|---|
| Sensitivity | 85.15 | 99.01 | < 0.001 |
| Specificity | 92.06 | 89.65 | 0.674 |
| PPV | 91.59 | 98.52 | < 0.001 |
| NPV | 85.92 | 92.86 | 0.317 |
| Kappa agreement % | 74.8 | 58.3 | <0.001 |
| Invalid results | 4/258 (1.5%) | 27/258 (10.5%) | <0.0001 |
| False positive results | 10/254 (3.9%) | 3/231 (1.2%) | 0.071 |
Comparison of Ct values between the saliva and NPS samples.
| Method | Sample | Mean ± SD |
| Correlation |
|
|---|---|---|---|---|---|
| BGI kit | Saliva | 14.19 ± 15.66 | 0.632 | 0.607 | <0.001 |
| NPS | 13.80 ± 13.43 | ||||
| Thermo Fisher kit | Saliva | 20.52 ± 12.79 | 0.343 | 0.472 | <0.001 |
| NPS | 21.24 ± 10.05 |