Literature DB >> 34325319

Luminescent wearable biosensors based on gold nanocluster networks for "turn-on" detection of Uric acid, glucose and alcohol in sweat.

Ziping Zhou1, Tong Shu2, Yafang Sun3, Hongxin Si4, Peiwen Peng3, Lei Su4, Xueji Zhang5.   

Abstract

From the difficulty of awareness of abnormal concentrations of biochemical indexes in people's daily life come wearable sensing technologies. Recently, luminescent wearable biosensors are emerging with simple fabrication, easy use, cost-effectivity and reliability. But several challenges should be taken up, such as availability of varied analytes, high sensitivity, stability of enzymes, photostability, low signal noises and recyclability of sensors. Here, the Luminescent Wearable Sweat Tape (LWST) biosensor is developed via embedding multi-component nanoprobes onto microwell-patterned paper substrates of hollowed-out double-side tapes. The nanoprobes consist of responsive luminophores, enzyme-loaded gold nanocluster (AuNCs) nano-networks, which are wrapped by the switch, MnO2 nanosheets. The responsive luminophores are constructed by 3 substitutable components: enzymes (uricase, GOx and alcohol dehydrogenase) for molecular target recognition, glutathione-protected AuNCs (yellow, red and green) for luminescent signal output and polycations PAH for integration. MnO2 NSs as the switch can quench the emission of the AuNCs but degraded by the reductive product of incorporated enzymes. Thus, targeting analysts (uric acid, glucose and alcohol) can be dose-dependently detected through "turn-on" luminescence approach. After incorporating the nanoprobes into hollow-out tapes, the formed LWST biosensors can detect uric acid, glucose and alcohol in sweat with the help of a smartphone. Subsequently, we primarily apply them into human daily life scenario, sampling from dine parties, and the positive relationships of analyte intakes and the increase of analytes in sweat are significant with individual difference.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Gold nanoclusters; Luminescence; Polymer networks; Sweat biomarkers; Wearable biosensor

Year:  2021        PMID: 34325319     DOI: 10.1016/j.bios.2021.113530

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  Electrochemical fabrication of Co(OH)2 nanoparticles decorated carbon cloth for non-enzymatic glucose and uric acid detection.

Authors:  Fang Wang; Fengna Shi; Cheng Chen; Kexin Huang; Naipin Chen; Ziqi Xu
Journal:  Mikrochim Acta       Date:  2022-09-20       Impact factor: 6.408

Review 2.  Smartphone-based mobile biosensors for the point-of-care testing of human metabolites.

Authors:  Meiying Zhang; Xin Cui; Nan Li
Journal:  Mater Today Bio       Date:  2022-04-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.