Matteo Trezzi, MDIn reoperative patients, difficult surgical operations may be converted to a less complex surgery combined with an interventional procedure.See Article page 121.In this issue of the Journal, Kalangos and colleagues report a case of pediatric tricuspid valve replacement on a beating heart using the Sapien 3 prosthesis (Edwards Lifesciences, Irvine, Calif). Currently, no tricuspid valve prostheses are available for infants and small children. Therefore, transcatheter valves have been surgically implanted with increasing success in the atrioventricular position with the intention that it allows for subsequent valve expansion in the catheterization laboratory as children grow. Based on its favorable design characteristics and performance in the right ventricular outflow tract position, the Melody valve (Medtronic, Minneapolis, Minn) was initially adapted for left atrioventricular valve replacement with promising results in pediatric patients.,More recently, the Sapien 3 valve was proposed as a valid alternative for mitral and tricuspid valve replacement., The stent height is shorter than that of the Melody, and it does not require surgical manipulation beforehand. In small annuli (ie, <19 mm), the Sapien 3 valve certainly appears promising compared with a fixed-diameter prosthesis. However, this valve has thick, stiff leaflets (designed to withstand aortic pressure) that may have poor mobility and may be prone to structural degeneration if complete valve expansion is not achieved. Nevertheless, the choice of the appropriate replacement valve is only one of the steps of a successful challenging surgical operation.Several features of the article merit mention. The authors are to be congratulated for their meticulous planning and execution of a complex operation. Cardiopulmonary bypass was instituted by directly cannulating the abdominal vessels through a retroperitoneal approach. A small right anterior thoracotomy was used for optimal exposure while avoiding resternotomy, and the entire procedure was performed on a beating heart, under transesophageal echocardiographic guidance to avoid any significant compression of the aortic annulus. Ultimately, because the tricuspid annulus was hypoplastic, the newly implanted valve was expanded to the predicted diameter (23 mm), leaving further room for future percutaneous dilatations (nominal valve size of 26 mm).Additional research is warranted to clarify the long-term durability and optimal postprocedural management of tricuspid transcatheter valve replacement. Antiplatelet therapy or even oral anticoagulation might be considered pending further data, along with strict echocardiographic surveillance of the implanted valve. When percutaneous delivery of the appropriate transcatheter valve is not an option, the surgeon's hope is that interventional techniques in combination with open surgery lead to optimal results.
Authors: Francesca R Pluchinotta; Breanna L Piekarski; Valentina Milani; Oliver Kretschmar; Phillip T Burch; Lale Hakami; David B Meyer; Frederic Jacques; Olivier Ghez; Matteo Trezzi; Adriano Carotti; Shakeel A Qureshi; Ina Michel-Behnke; James M Hammel; Paul Chai; David McMullan; Bret Mettler; Queralt Ferrer; Mario Carminati; Sitaram M Emani Journal: Circ Cardiovasc Interv Date: 2018-11 Impact factor: 6.546
Authors: Ibrahim Abdullah; Francisco Boye Ramirez; Doff B McElhinney; James E Lock; Pedro J del Nido; Sitaram Emani Journal: Ann Thorac Surg Date: 2012-10 Impact factor: 4.330