Commentary: Leaflet perforation after transcatheter aortic valve replacement: An unsuspected complication with underestimated outcomes.

Samantha Guimaron1, Dimitri Kalavrouziotis1, Siamak Mohammadi1.   

Abstract

Entities:  

Year:  2020        PMID: 34317830      PMCID: PMC8302926          DOI: 10.1016/j.xjtc.2020.04.014

Source DB:  PubMed          Journal:  JTCVS Tech        ISSN: 2666-2507


× No keyword cloud information.
Siamak Mohammadi, MD, FRCSC, Samantha Guimaron, MD, MSc, and Dimitri Kalavrouziotis, MD, FRCSC Leaflet perforation after transcatheter aortic valve implantation is a rare complication that may alter valve durability due to transcatheter valve leaflet vulnerability. See Article page 92. The indications for transcatheter aortic valve replacement (TAVR) have recently been widened to low-surgical risk patients. As surgical risk decreases, so does the average age of the patients. One major consideration remains: TAVR prosthesis durability, which has been poorly investigated thus far. Several authors have suggested that different mechanisms, all involving some extent of leaflet damage, including cusp rupture, leaflet thrombosis, and accelerated calcification, could have major consequences on valve durability and therefore on patient outcomes after TAVR., These lesions appear to be responsible for aortic regurgitation and the need for surgical explant. However, these lesions remain underdiagnosed. In this issue of the Journal, Liesman and Fukuhara report 2 cases of leaflet perforation with a need for surgical explant. These cases share several common aspects: first, both patients had a history of chest radiation therapy with severe root calcification; second, both cases received a TAVR procedure with a self-expandable valve after a primary sternotomy; and third, surgical explant because of aortic regurgitation was required in both cases after a short period following the TAVR procedure: 3 and 5.8 years. Similar macroscopic findings were also noted: neo-endothelialization of the TAVR prosthesis nitinol frame into the aortic wall, with a perforation/tear located on the right coronary cusp. Liesman and Fukuhara unmask a major unknown of TAVR prostheses: valve durability/longevity. The 2 cases occurred in the early- to mid-term follow-up post-TAVR, which suggests that leaflet fragility could have a negative impact on valve durability. Hypothetic risk factors for leaflet perforation were additional postdeployment balloon dilatation, as well as crimping of the prosthesis, which has also been reported by others. In addition, they suggested that valve durability could be further affected by implanting the prosthesis into an undecalcified native aortic valve and aortic root. This article is important because the authors effectively shed some light into a potential mechanical failure of TAVR due to the leaflet injury. The newer generation of TAVR bioprostheses has leaflets that are generally thinner to accommodate the smaller caliber of the delivery sheaths, which may translate into a potentially increased fragility of the leaflets. Further mechanical stress may be due to the crimping process, recapturing, and postdeployment balloon dilatation, and may render the leaflets vulnerable to perforation and subsequent thrombosis, although these theories remain hypothetical. Further studies are needed to assess these issues. Liesmann and Fukuhara have exposed a novel but potentially underdiagnosed complication of TAVR prosthetic leaflet perforation. The durability of TAVR prostheses should be considered in our decisional algorithm when assessing the optimal approach to aortic stenosis, especially in younger patients.
  5 in total

1.  Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients.

Authors:  Michael J Mack; Martin B Leon; Vinod H Thourani; Raj Makkar; Susheel K Kodali; Mark Russo; Samir R Kapadia; S Chris Malaisrie; David J Cohen; Philippe Pibarot; Jonathon Leipsic; Rebecca T Hahn; Philipp Blanke; Mathew R Williams; James M McCabe; David L Brown; Vasilis Babaliaros; Scott Goldman; Wilson Y Szeto; Philippe Genereux; Ashish Pershad; Stuart J Pocock; Maria C Alu; John G Webb; Craig R Smith
Journal:  N Engl J Med       Date:  2019-03-16       Impact factor: 91.245

2.  The effects of transcatheter valve crimping on pericardial leaflets.

Authors:  S Hamed Alavi; Elliott M Groves; Arash Kheradvar
Journal:  Ann Thorac Surg       Date:  2014-01-18       Impact factor: 4.330

3.  Surgical explantation of transcatheter aortic bioprostheses: Results and clinical implications.

Authors:  Shinichi Fukuhara; Alexander A Brescia; Suzuna Shiomi; Carlo M Rosati; Bo Yang; Karen M Kim; G Michael Deeb
Journal:  J Thorac Cardiovasc Surg       Date:  2020-01-12       Impact factor: 6.439

4.  Extremely early structural failure of a self-expanding transcatheter aortic valve secondary to leaflet dehiscence.

Authors:  Hanna Park; Stephane Leung Wai Sang; William M Merhi
Journal:  JTCVS Tech       Date:  2020-03-19

5.  Leaflet perforation or tear late after transcatheter aortic valve implantation.

Authors:  Daniel R Liesman; Shinichi Fukuhara
Journal:  JTCVS Tech       Date:  2020-04-11