Commentary: Strength at the cutting edge.

Song Wan1, Jun Liu2.   

Abstract

Entities:  

Year:  2020        PMID: 34317752      PMCID: PMC8298826          DOI: 10.1016/j.xjtc.2020.02.008

Source DB:  PubMed          Journal:  JTCVS Tech        ISSN: 2666-2507


× No keyword cloud information.
Song Wan, MD, FRCS, and Jun Liu, PhD To strengthen the potential “weakest link” of the adjustable neochordae implantation technique, CV4 polytetrafluoroethylene sutures should be used in preference to the originally proposed CV5 sutures. See Article page 50. Implantation of artificial neochordae made of expanded polytetrafluoroethylene (ePTFE) has been a mainstay technology in mitral valve repair. Determining the proper length of a neochord intraoperatively, however, is not always straightforward for surgeon. Occasionally, the dynamic changes that occur during cardiac cycles following the release of the aortic crossclamp can unexpectedly impair a “perfect fit” neochord that was measured on an arrested heart and tested by saline injection through the mitral valve to fill the left ventricle. That multiple methods have been developed to address this neochordal-measurement issue reflects its intrinsic complexity as well as the lack of an “ideal” strategy to overcome the multifarious difficulties involved in neochordae implantation. In this regard, Sotolongo and colleagues' adjustable neochordae implantation technique is definitely auspicious. It proves that innovation is always born of necessity, as this ingenious new method can apparently facilitate intraoperative neochordal adjustment. Sotolongo and colleagues have successfully applied this technique in 22 patients (the majority through a minimally invasive approach) and have achieved excellent short-term outcomes. Nonetheless, the strength of any innovation can often be defined by its “weakest link.” After a brief analysis, we must conclude that the CV-5 type of ePTFE sutures chosen by Sotolongo and colleagues might not be adequate. In the new adjustable technique, 2 arms of the ePTFE sutures are passed through the corresponding papillary muscle, then pulled toward the annular base and secured on the atrial side of the posterior mitral annulus. As illustrated in Figure 1, A, whereas the conventional method directly connects the edge of the mitral valve leaflet with the papillary muscle (shown as a green dashed line), the new technique uses longer neochordae (shown as red lines in Figure 1, B). The increased length may increase the risk of neochordae rupture, which has been observed in transapical neochordae implantations. Previous studies have indicated that increased length of neochordae correlates with an escalation in stiffness. Change in the neochord anchoring angle may result in greater forces being exerted on the neochordae suture, as well as an increased rate of loading on the neochordae compared with the conventional fixation. Moreover, the adjustable arms at the annular side will unavoidably produce a side-pulling force and further increase the tension applied to the neochordae. When peak systolic blood pressure is reached, the new adjustable technique is expected to generate an effective holding force via the neochordae to reach an equilibrium state similar to that in the conventional method, where the systolic force F is equal to the chordae holding force F:
Figure 1

Diagram of the mechanics of the conventional and adjustable methods of neochordae implantation. A, The conventional method directly connects the PMVL and the papillary muscle with a maximum tension force F. B, In the adjustable method, longer neochords are used and the adjustable arms pull the papillary muscles sideways with increased force (F). The forces applied to the papillary muscles F are also greater than that in the conventional method. PMVL, Posterior mitral valve leaflet; SBP, systolic blood pressure.

Diagram of the mechanics of the conventional and adjustable methods of neochordae implantation. A, The conventional method directly connects the PMVL and the papillary muscle with a maximum tension force F. B, In the adjustable method, longer neochords are used and the adjustable arms pull the papillary muscles sideways with increased force (F). The forces applied to the papillary muscles F are also greater than that in the conventional method. PMVL, Posterior mitral valve leaflet; SBP, systolic blood pressure. In the new adjustable technique, the tension applied on the neochordae F can be broken down into 2 components: F1 = F along the green dashed line; and F2 caused by the adjustable end of the neochordae. From the force analysis, we have F = F ∗ cos α, where α is the angle between the neochordae in the adjustable method and the conventional method (see Figure 1, B). Therefore, the force applied to the neochordae in the adjustable technique is greater than that in the conventional method (ie, F > F). When analyzing the force on the penetrating point at the papillary muscle, we further find that the force exerted on the papillary muscle F is also increased. As shown in the inset of Figure 1, B, we have F = 2F cos β, where β is equal to half of the angle between the neochord portions penetrating into and out of the papillary muscle. Based on the anatomy of the left ventricle, one can assume that β could be less than 30°. Therefore, we have cos β > 0.866 and F > 1.732F. Compared with the classical method where the force applied to the papillary muscle directly equals the neochordal tension, the new technique produces a significantly increased pulling force on the papillary muscle that could increase the risk of cutting through the papillary muscle tip or causing a remodeling of papillary anatomy. This mechanics analysis (Figure 1) is necessarily simplified and may not be accurate, given the complex anatomy of the ventricle and the mitral valve. However, it should be noted that the new technique inevitably uses longer ePTFE neochordae than the conventional method and applies increased tension to the neochordae. Considering the altered mechanics associated with the adjustable technique, we recommend use of neochordae with increased strength to reduce the risk of the neochordal rupture. To summarize, in applying the new adjustable neochordae implantation technique, the sutures chosen should probably be CV-4 ePTFE, rather than the originally proposed CV-5. Although Sotolongo and colleagues deserve congratulations for their innovative modification, we eagerly await their long-term follow-up data.
  4 in total

1.  Artificial mitral chordae: When length matters.

Authors:  Daniel Grinberg; Kaled Adamou Nouhou; Matteo Pozzi; Jean-François Obadia
Journal:  J Thorac Cardiovasc Surg       Date:  2018-09-29       Impact factor: 5.209

2.  A study of the mechanical properties of ePTFE suture used as artificial mitral chordae.

Authors:  Philippe Primo Caimmi; Maurizio Sabbatini; Luca Fusaro; Alessia Borrone; Mario Cannas
Journal:  J Card Surg       Date:  2016-07-08       Impact factor: 1.620

3.  Ex Vivo Biomechanical Study of Apical Versus Papillary Neochord Anchoring for Mitral Regurgitation.

Authors:  Annabel M Imbrie-Moore; Michael J Paulsen; Akshara D Thakore; Hanjay Wang; Camille E Hironaka; Haley J Lucian; Justin M Farry; Bryan B Edwards; Jung Hwa Bae; Mark R Cutkosky; Y Joseph Woo
Journal:  Ann Thorac Surg       Date:  2019-03-02       Impact factor: 4.330

4.  Mitral valve repair using adjustable posterior leaflet neochords.

Authors:  Alex Sotolongo; Syed Usman Bin Mahmood; Ben Vaccaro; Arnar Geirsson
Journal:  JTCVS Tech       Date:  2020-02-29
  4 in total