Literature DB >> 34316946

Aorto-Right Ventricular Fistula and Paravalvular Leak After Transcatheter Aortic Valve Implantation.

Ahmed M Alabbady1, Sudhakar Sattur2, Terry D Bauch3, Kishore J Harjai3.   

Abstract

Aorto-right ventricular fistula is a potentially fatal complication following transcatheter aortic valve implantation (TAVI). This paper presents a case of successful percutaneous repair of aorto-right ventricular fistula and paravalvular leak after TAVI by using 3D-printed models for pre-procedural planning, and a review of published aorto-right ventricular fistula cases to date. (Level of Difficulty: Advanced.).
© 2019 The Authors.

Entities:  

Keywords:  CT, computed topography; PPM, permanent pacemaker; PVL, paravalvular leak; Qp, pulmonary flow; Qs, systemic flow; TAVI, transcatheter aortic valve implantation; VSD, ventricular septal defect; aortic valve; complication; valve replacement

Year:  2019        PMID: 34316946      PMCID: PMC8288756          DOI: 10.1016/j.jaccas.2019.11.025

Source DB:  PubMed          Journal:  JACC Case Rep        ISSN: 2666-0849


Case

Presentation

A 76-year-old male presented for evaluation of symptomatic severe aortic stenosis. Despite having a Society of Thoracic Surgeon score of 3%, he was recommended for transcatheter aortic valve replacement (TAVR) by 2 surgeons due to his comorbidities.

Learning Objectives

To recognize and anticipate aorto-right ventricular (RV) fistula as an early complication of transcatheter aortic valve implantation; To realize the safety and feasibility of percutaneous closure of aorto-RV fistula; To recognize the role of the 3-dimensional models in planning complex structural heart interventions.

Medical history

The patient had a medical history significant for chronic obstructive pulmonary disease, obstructive sleep apnea with reported noncompliance with continuous positive airway pressure therapy, severe arthritis, and polyneuropathy which severely limited his ambulation capacity and gait stability, and paroxysmal atrial fibrillation on chronic anticoagulation.

Investigations

Transthoracic echocardiography showed an aortic valve mean gradient of 51 mm Hg, a peak velocity of 4.2 m/s, and an aortic valve area of 0.6 cm2. Pre-procedural computed tomography (CT) (Figure 1) was performed, and an aortic annulus of 32- × 26-mm with an area of 660 mm2 was measured.
Figure 1

Pre-Transcatheter Aortic Valve Replacement Computed Topography

Pre-Transcatheter Aortic Valve Replacement Computed Topography

Initial intervention

The patient underwent transesophageal echocardiogram-guided TAVR using a Sapien 3 29-mm (Edwards Lifescience, Irvine, California) using a right femoral approach at an outside hospital. Immediately after deployment, there was evidence of a moderate paravalvular leak (PVL), and additional balloon inflations reduced the leak to mild. The procedure was complicated immediately by new first-degree atrio-ventricular block, and left bundle branch block requiring temporary pacing. At 3 days after the procedure, the patient developed complete heart block and underwent permanent pacemaker placement. Transthoracic and transesophageal echocardiograms showed aorto-right ventricular fistula with a concern for supra-annular tear or rupture with a small PVL. He was hemodynamically stable and so was managed conservatively. Two weeks later, he was rehospitalized for syncope and was noted to be in clinical acute heart failure. His permanent pacemaker (PPM) was interrogated and showed unsustained ventricular tachycardia. A repeated transthoracic echocardiography did not show any significant change from prior tests, suggesting increased right ventricular pressure and volume overload as possible causes for his ventricular tachycardia. Electrophysiology staff were consulted and recommended that the patient be discharged on LifeVest (Zoll Medical, Chelmsford, Massachusetts) pending closure of his fistula and PVL. Right heart catheterization done at that admission showed a pulmonary flow/systemic flow (Qp/Qs) ratio of 1.43. A heart team discussion was held, and the decision was to pursue percutaneous approach. The patient was subsequently transferred to the authors’ hospital for further management of aorto-right ventricular fistula and PVL. The fistula was measured and evaluated by cardiac CT (Figure 2). CT data were processed with Mimics Innovation Suite software (Materialise, Leuven, Belgium) to create a 3-dimensional (3D) model incorporating the relevant anatomy and printed (Figure 3) using an Objet 360 printer (Statasys, Eden Prarie, Minnesota). This model was reviewed by the interventional team to aid in planning the procedure.
Figure 2

Computed Tomography Scan Images Showing the Anatomy of the Aorto-Right Ventricular Fistula

Figure 3

3-Dimensional Model of the Patient’s Aortic Valve and Ascending Aorta Showing the Prosthetic Valve and the Aorto-Right Ventricular Fistula Location

Computed Tomography Scan Images Showing the Anatomy of the Aorto-Right Ventricular Fistula 3-Dimensional Model of the Patient’s Aortic Valve and Ascending Aorta Showing the Prosthetic Valve and the Aorto-Right Ventricular Fistula Location

Management

Under transesophageal guidance (Video 1), the defect was crossed with a Wholey wire (Covidien, Mansfield, Massachusetts) (Video 2), over which a glide catheter was advanced, and then an Amplatzer Super Stiff wire (Boston Scientific, Marlborough, Massachusetts) was advanced. The glide catheter and 6-F left femoral artery sheath were removed and a 7-F shuttle sheath was advanced from left femoral artery to right ventricle. An 8-mm ventricular septal defect (VSD) closure device was then advanced across the fistula (Video 3). The RV sheath was deployed, and the left side disc was unsheathed. The device was examined fluoroscopically in multiple views. Despite the left side disc expansion being limited by the transcatheter aortic valve implantation (TAVI) prosthesis, multiple push and pull maneuvers confirmed device stability, and it was successfully deployed (Figure 4).
Online Video 1
Online Video 2
Online Video 3
Figure 4

Fluoroscopic Image of Successful Implantation of Ventricular Septal Defect Occluder Device

Transesophageal echocardiography with color doppler across the fistula tract. Crossing the fistula using Wholey wire. Delivery of the VSD closure device using 7-F shuttle sheath. VSD = ventricular septal defect. Fluoroscopic Image of Successful Implantation of Ventricular Septal Defect Occluder Device Post-deployment transesophageal echocardiogram (Video 4) shunt study showed reduction in right ventricle saturations from 88% to 63% in setting of right ventricle saturations of 60%, suggesting nearly complete abolition of left-to-right shunt. The patient was discharged home on therapy that included aspirin, 81 mg, warfarin, dose managed by anticoagulation pharmacy, metoprolol tartrate, 50 mg twice daily, and daily torsemide, 20 mg daily. Four months after the procedure, the patient was brought back to close his paravalvular leak that had progressed in severity, requiring 2 Amplatzer vascular plugs, 8-mm devices deployed successfully (Figure 5) under transesophageal echocardiogram guidance (Videos 5, 6, 7, 8, and 9). Electrophysiology reevaluated the patient at that time. He had no shocks from his LifeVest. His PPM interrogation showed no recurrence of his ventricular tachycardia, and recommendations were against upgrading his PPM to an automatic implantable cardioverter defibrillator. Use of his LifeVest was discontinued, and he was discharged home on unchanged medical regimen.
Online Video 4
Figure 5

Final Fluoroscopic Image After Successful Implantation of Ventricular Septal Defect and 2 Amplatzer Vascular Plugs

Online Video 5
Online Video 6
Online Video 7
Online Video 8
Online Video 9
Transesophageal echocardiography after device deployment showing near complete cessation of flow across the fistula. Final Fluoroscopic Image After Successful Implantation of Ventricular Septal Defect and 2 Amplatzer Vascular Plugs TEE showing color doppler across the paravalvular leak. TEE = transesophageal echocardiogram. Successful crossing of the PVL. PVL = paravalvular leak. Delivery of the first AVP across the PVL. AVP = Amplatzer vascular plug; other abbreviation as in Video 6. Delivery of the second AVP across the PVL. Abbreviations as in Videos 6 and 7. Transesophageal echocardiography with color Doppler after deployment of the second AVP across the PVL. Abbreviations as in Videos 6 and 7. At 23 months follow-up, the patient continued to do well with NYHA functional class II symptoms on a chronic regimen of aspirin, 81 mg daily, warfarin, dose managed by anticoagulation clinic, metoprolol tartrate, 50 mg twice daily, and diuretic therapy with daily 20 mg of torsemide. Follow- up transthoracic echocardiograms showed normally functioning prosthesis, no further PVL, and a well-seated VSD device with a small leak around the device, but no significant shunting was noted. His routine device interrogation showed no further recurrence of his ventricular tachycardia.

Discussion

Despite the fact that aorto-RV fistula is a rare complication, the increasing number of TAVR procedures used across the United States will result in encountering rare complications more frequently. There are no guidelines available to assist with management of those patients. Aorto-RV fistula closure using a percutaneous device represents a technical challenge because the TAVI valve is expected to interfere with secure placement of larger closure devices like VSD occludes. This paper reports the case of successful closure of aorto-RV fistula and PVL after TAVI using a VSD occluder device and 2 Amplatzer vascular plugs. A comprehensive search of published studies revealed only 12 cases of aorto-RV fistula following TAVR with high mortality rate (Table 1) (1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12). All 4 patients who underwent percutaneous repair survived, and 3 of the other 8 cases managed conservatively died. Society of Thoracic Surgeon scores, root measurements, or aortic calcifications were not reported in those cases. All patients were treated using balloon expandable valves. All had significant left-to-right shunts which were evident by high Qp/Qs ratios with the onset of congestive heart failure symptoms in 2 to 4 weeks after the index procedure.
Table 1

Comparison of All Published Cases of Aorto-RV Fistula

First Author (Ref. #)Age, yrs/SexValve SizePVL Onset After TAVIReported SymptomsQp/Qs RatioManagementOutcome
Shakoor et al. (1)89/MSAPIEN 29-mm30 daysDyspnea on exertion1.39ObservationDied
Pilgrim et al. (2)91/FSAPIEN 26-mm1 monthDyspnea on exertion1.4Coil embolizationSurvived
Leroux et al. (3)47/MSAPIEN XT 26-mm3 weeksN/AN/AObservationDied
Leu et al. (4)78/FSAPIEN 26-mm2 weeksN/A1.13ObservationSurvived
Muñoz-García et al. (5)85/MCoreValve 29-mm72 hAsymptomatic1.53ObservationSurvived
Nakamura et al. (6)54/MSAPIEN XT 29-mm5 daysBiV failure1.7ASD occluderSurvived
Hagiwara et al. (7)83/MSAPIEN XT 29-mmImmediateN/A1ObservationSurvived
Hamandi et al. (8)93/MSAPIEN XT 29-mm1 dayN/AVSD occluderSurvived
Almanfi et al. (9)92/MSAPIENT XT 29-mm1 dayAsymptomaticnoneObservationSurvived
Vainrib et al. (10)91/MCoreValve 29-mm4 monthsCHF symptomsN/AAVP vascular plugSurvived
Verma et al. (11)80/MCoreValve 29-mm, followed by second CoreValve 29-mm for severe intravalvular leakImmediateAsymptomatic1ObservationSurvived
Konda et al. (12)88/FSAPIEN XT 26-mm2 weeksNone initially, then developed CHF after 3 months2:1RefusedDied
Alabbady et al.76/MSapien 3 29-mm2 weeksProgressive since procedure, CHF 2 weeks1.43VSD occluderSurvived

ASD = atrial septal defect; BiV = bi-ventricular; CHF = congestive heart failure; N/A = not available; PVL = paravalvular leak; Qp/Qs = pulmonary flow/systemic flow ratio; RV = right ventricle; TAVI = transcatheter aortic valve implantation; VSD = ventricular septal defect.

Comparison of All Published Cases of Aorto-RV Fistula ASD = atrial septal defect; BiV = bi-ventricular; CHF = congestive heart failure; N/A = not available; PVL = paravalvular leak; Qp/Qs = pulmonary flow/systemic flow ratio; RV = right ventricle; TAVI = transcatheter aortic valve implantation; VSD = ventricular septal defect.

Conclusions

Aorto-RV fistula is a rare but serious and potentially fatal complication following TAVR. Percutaneous repair is feasible and safe and should be strongly considered in symptomatic patients with significant Qp/Qs ratios. More data are needed to evaluate outcomes and determine the optimal strategies for repair.
  2 in total

1.  Successful percutaneous closure of aortic root-to-right ventricle fistula after transcatheter aortic valve implantation: a valuable option in high-risk surgical patients.

Authors:  Apostolos Vrettos; Alison Duncan; Asrar Ahmed; Ee Ling Heng; Vasileios Panoulas
Journal:  Eur Heart J Case Rep       Date:  2022-02-22

2.  A Sharp Right Turn: A Case of Aortic to Right Atrial Fistula During Transcatheter Aortic Valve Replacement.

Authors:  Benjamin M Kristobak; Theodore J Cios
Journal:  Am J Case Rep       Date:  2022-07-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.