Literature DB >> 34316921

Spontaneous Internal Mammary Artery Graft Dissection Triggered by Emotional Stress.

Kosuke Sawami1, Masahiro Natsuaki1, Hiroshi Hongo1, Masataka Kajiwara1, Tetsuya Kaneko1, Yohei Inoue1, Aiko Komatsu1, Norihiko Kotooka1, Yutaka Hikichi1, Koichi Node1.   

Abstract

Internal mammary artery graft dissection is a rare condition and is usually caused by iatrogenic complications or mechanical stress. We experienced a case of acute myocardial infarction due to spontaneous internal mammary artery graft dissection that was triggered by emotional stress and was successfully treated by percutaneous intervention using drug-eluting stents. (Level of Difficulty: Beginner.).
© 2019 The Authors.

Entities:  

Keywords:  CABG, coronary artery bypass grafting; IMA, internal mammary artery; LAD, left anterior descending artery; LCX, left circumflex artery; SCAD, spontaneous coronary artery dissection; acute coronary syndrome; coronary artery bypass; dissection

Year:  2019        PMID: 34316921      PMCID: PMC8288662          DOI: 10.1016/j.jaccas.2019.09.023

Source DB:  PubMed          Journal:  JACC Case Rep        ISSN: 2666-0849


Internal mammary artery (IMA) dissection is a rare condition and could be caused by iatrogenic complications (1,2). Therefore, there are few reports of spontaneous IMA dissection. Here, we present a case of acute myocardial infarction due to spontaneous IMA graft dissection that was triggered by emotional stress and was successfully treated by percutaneous intervention using drug-eluting stents.

Learning Objectives

Spontaneous IMA graft dissection is one of the causes of acute coronary syndrome in patients with a previous history of CABG. Emotional stress as well as the mechanical stress due to physical movement is a possible trigger for spontaneous IMA graft dissection. Percutaneous intervention using coronary stents is one of the important treatment options in cases of spontaneous IMA graft dissection.

History of Presentation

A 78-year-old woman was admitted to our hospital with sudden onset chest pain immediately after receiving notice of her grandchild's death. Chest pain was relieved by oral nitroglycerin but persisted when she arrived at our hospital. She did not complain of backache or nausea. Her blood pressure on arrival was 150/87 mm Hg and her heart rate was 64 beats/min. Her heart had a regular rhythm; S1 and S2 were normal, and there were no murmurs or gallops. There was no lower extremity edema.

Past medical history

She had been treated for hypertension and dyslipidemia by oral medications. She experienced effort angina and underwent coronary artery bypass grafting (CABG) 20 years prior with a left IMA graft to the diagonal branch and saphenous vein grafts to the left anterior descending artery (LAD), left circumflex artery (LCX), and right coronary artery. The saphenous vein graft to the LCX was occluded immediately after CABG. The LCX was treated by percutaneous coronary intervention using a 2.5 × 28 mm Cypher sirolimus-eluting stent (Cordis Medical, Hialeah, Florida) owing to unstable angina 11 years prior. Furthermore, the saphenous vein graft to the LAD showed occlusion based on angiography performed 1 year prior.

Differential diagnosis

Differential diagnosis included plaque rupture of the bypass graft, acute coronary syndrome due to plaque rupture, spontaneous coronary artery dissection (SCAD), very late stent thrombosis, Takotsubo cardiomyopathy, and myocarditis.

Investigations

The electrocardiogram showed ST-segment elevation in leads I, aVL, and V2 to V6 (Figure 1). The left ventricular lateral wall was hypokinetic on echocardiography. Troponin T was elevated to 1.06 ng/ml (normal <0.014 ng/ml).
Figure 1

Electrocardiogram

Electrocardiogram from 1 year prior and at the onset.

Electrocardiogram Electrocardiogram from 1 year prior and at the onset.

Management

Urgent angiography showed severe stenosis at the mid portion of the left IMA graft with Thrombolysis In Myocardial Infarction flow grade 2, which was not observed 1 year prior (Figure 2). There were no significant changes in the native coronary artery. Therefore, left IMA stenosis was considered to be the culprit lesion and percutaneous intervention was selected for the treatment of this challenging case.
Figure 2

Angiography of the IMA Graft

(A) Internal mammary artery (IMA) angiography from 1 year ago. (B) IMA graft angiography at the onset with Thrombolysis In Myocardial Infarction flow grade 2.

Angiography of the IMA Graft (A) Internal mammary artery (IMA) angiography from 1 year ago. (B) IMA graft angiography at the onset with Thrombolysis In Myocardial Infarction flow grade 2. The left radial artery was selected as an approach site, and a 6-F Judkins Right 3.5 guiding catheter (Medtronic, Minneapolis, Minnesota) was used for the intervention. A SION blue wire (Asahi Intecc USA, Santa Ana, California) did not pass the culprit lesion due to insufficient backup. Therefore, the approach site was changed to the femoral artery, and the wire successfully advanced through the lesion. Intravascular ultrasound revealed dissection with intramural hematoma throughout the stenotic lesion (Figure 3). The intramural hematoma and dissection flap were fully stented using 2 platinum chromium SYNERGY everolimus-eluting stents (2.5 × 38 mm and 2.5 × 12 mm; Boston Scientific, Marlborough, Massachusetts). Final angiography showed good stent expansion with TIMI flow grade 3 (Figure 4).
Figure 3

Intravascular Ultrasound Findings

Angiography and intravascular ultrasound findings. Asterisks show intramural hematoma.

Figure 4

Angiography of the IMA Graft

(A) Internal mammary artery (IMA) graft angiography before percutaneous coronary intervention. (B) IMA graft angiography after percutaneous coronary intervention with Thrombolysis In Myocardial Infarction flow grade 3.

Intravascular Ultrasound Findings Angiography and intravascular ultrasound findings. Asterisks show intramural hematoma. Angiography of the IMA Graft (A) Internal mammary artery (IMA) graft angiography before percutaneous coronary intervention. (B) IMA graft angiography after percutaneous coronary intervention with Thrombolysis In Myocardial Infarction flow grade 3. The patient’s symptoms resolved after percutaneous coronary intervention, and the serum creatine kinase increased up to 521 U/l. She was discharged from our hospital on post-operative day 9.

Discussion

IMA graft dissection is considered to be very important condition because of its frequent use for LAD bypass grafting. One of the major causes of IMA graft dissection is iatrogenic complications. Shammas et al. (1) reported a case in which dissection of the IMA graft occurred during diagnostic angiography and was treated successfully with a drug-eluting stent. Spontaneous IMA graft dissection is another cause (2), and it is crucially important, as it can lead to acute coronary syndrome (3, 4, 5, 6). Koyama et al. (7) reported spontaneous dissection of an IMA graft causing acute coronary syndrome and ventricular fibrillation. Although spontaneous IMA graft dissection is not common, we should keep in mind that it could be the cause of acute coronary syndrome or life-threatening arrhythmia in those with previous CABG. The main cause of spontaneous IMA dissection has been reported to be associated with mechanical stress owing to physical movement (Table 1) (3,4,6). Freixa and Gallo (6) proposed that the shear stress between the chest wall and IMA triggered dissection. In this case, the patient was exposed to emotional stress upon notification of her grandchild's death, and then chest pain occurred. It is possible that emotional stress could have been the cause of IMA dissection in this case. Emotional stress is reported to be a major trigger of SCAD (8). Stress catecholamines could increase the arterial shear stress, resulting in dissection (9). The same mechanism may have caused dissection of the IMA in this case.
Table 1

Reported Cases of Spontaneous IMA Dissection

First Author (Ref. #)YearAge (yrs)SexTriggerTreatment
Wong et al. (3)200469MDigging up a postbox4 stents
Suresh and Evans (4)200775MLifting a heavy bookcaseMultiple stents
Karabulut and Tanriverdi (5)201159FKinking of the IMACABG
Freixa and Gallo (6)201361MRaising arms3 stents
Koyama et al. (7)201547MNo specific trigger2 stents
Current case201978FEmotional stress2 stents

CABG = coronary artery bypass grafting; IMA = internal mammary artery.

Reported Cases of Spontaneous IMA Dissection CABG = coronary artery bypass grafting; IMA = internal mammary artery. On the one hand, a conservative strategy is mostly selected in cases of SCAD. Only 14% of patients had percutaneous coronary intervention in the Canadian SCAD cohort study (8). On the other hand, percutaneous intervention using coronary stents is the major treatment strategy for IMA dissection (Table 1) (3,4,6,7). Percutaneous intervention to the IMA is usually challenging because of the acute angle, tortuous course, and small lumen of the IMA. However, balloon angioplasty and stenting of IMA is reported to be safe and effective (10). Although the prior report did not refer to dissection cases, percutaneous intervention could be a valuable treatment option to treat flow-limited IMA dissection cases, considering the risk of reoperation in those with previous CABG. Nevertheless, the dilemma of whether to perform intervention or not remains in the spontaneous IMA dissection. As there was no evidence of any disease 1 year prior, the dissected IMA could have been healed completely without intervention. Furthermore, there is a risk of propagating dissection by the wiring to the false lumen. In this case, intervention was selected due to the ongoing chest pain and flow limitation of IMA. Arrhythmias or hemodynamic instability could also be the indication of intervention for spontaneous IMA dissection. This case uniquely demonstrates emotional stress as a possible trigger of IMA graft dissection and complements previous case reports demonstrating the role of percutaneous intervention in its management.

Follow-up

The patient did well at 1 month of follow-up in our hospital. Echocardiography showed left ventricular lateral wall motion that was mildly hypokinetic, but it was better than that at the onset.

Conclusions

To the best of our knowledge, this could be the first case of spontaneous IMA graft dissection that was triggered by emotional stress and successfully treated by percutaneous intervention.
  1 in total

1.  Late spontaneous internal thoracic artery graft dissection after coronary bypass grafting: a case report.

Authors:  Kasumi Ishibuchi; Shin Yajima; Wataru Yamamoto; Satoru Otsuji
Journal:  Eur Heart J Case Rep       Date:  2022-02-10
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.