Literature DB >> 34315136

Proof-of-concept for x-ray based real-time image guidance during cardiac radioablation.

Nicholas Hindley1, Suzanne Lydiard1,2, Chun-Chien Shieh1,3, Paul Keall1.   

Abstract

Cardiac radioablation offers non-invasive treatments for refractory arrhythmias. However, treatment delivery for this technique remains challenging. In this paper, we introduce the first method for real-time image guidance during cardiac radioablation for refractory atrial fibrillation on a standard linear accelerator. Our proposed method utilizes direct diaphragm tracking on intrafraction images to estimate the respiratory component of cardiac substructure motion. We compare this method to treatment scenarios without real-time image guidance using the 4D-XCAT digital phantom. Pre-treatment and intrafraction imaging was simulated for 8 phantoms with unique anatomies programmed using cardiorespiratory motion from healthy volunteers. As every voxel in the 4D-XCAT phantom is labelled precisely according to the corresponding anatomical structure, this provided ground-truth for quantitative evaluation. Tracking performance was compared to the ground-truth for simulations with and without real-time image guidance using the left atrium as an exemplar target. Differences in target volume size, mean volumetric coverage, minimum volumetric coverage and geometric error were recorded for each simulation. We observed that differences in target volume size were statistically significant (p < 0.001) across treatment scenarios and that real-time image guidance enabled reductions in target volume size ranging from 11% to 24%. Differences in mean and minimum volumetric coverage were statistically insignificant (bothp = 0.35) while differences in geometric error were statistically significant (p = 0.039). The results of this study provide proof-of-concept for x-ray based real-time image guidance during cardiac radioablation.
© 2021 Institute of Physics and Engineering in Medicine.

Entities:  

Keywords:  cardiac; guidance; radioablation; real-time

Mesh:

Year:  2021        PMID: 34315136      PMCID: PMC8815757          DOI: 10.1088/1361-6560/ac1834

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  33 in total

1.  Stereotactic radiosurgery for ablation of ventricular tachycardia.

Authors:  Radek Neuwirth; Jakub Cvek; Lukas Knybel; Otakar Jiravsky; Lukas Molenda; Michal Kodaj; Martin Fiala; Petr Peichl; David Feltl; Jaroslav Januška; Jan Hecko; Josef Kautzner
Journal:  Europace       Date:  2019-07-01       Impact factor: 5.214

2.  Noninvasive Cardiac Radiation for Ablation of Ventricular Tachycardia.

Authors:  Phillip S Cuculich; Matthew R Schill; Rojano Kashani; Sasa Mutic; Adam Lang; Daniel Cooper; Mitchell Faddis; Marye Gleva; Amit Noheria; Timothy W Smith; Dennis Hallahan; Yoram Rudy; Clifford G Robinson
Journal:  N Engl J Med       Date:  2017-12-14       Impact factor: 91.245

3.  Real-time direct diaphragm tracking using kV imaging on a standard linear accelerator.

Authors:  Nicholas Hindley; Paul Keall; Jeremy Booth; Chun-Chien Shieh
Journal:  Med Phys       Date:  2019-08-13       Impact factor: 4.071

4.  Towards real-time MRI-guided 3D localization of deforming targets for non-invasive cardiac radiosurgery.

Authors:  S Ipsen; O Blanck; N J Lowther; G P Liney; R Rai; F Bode; J Dunst; A Schweikard; P J Keall
Journal:  Phys Med Biol       Date:  2016-10-25       Impact factor: 3.609

Review 5.  Radiotherapy for ablation of ventricular tachycardia: Assessing collateral dosing.

Authors:  Roy M John; Eric T Shinohara; Michael Price; William G Stevenson
Journal:  Comput Biol Med       Date:  2018-08-11       Impact factor: 4.589

6.  On-line use of three-dimensional marker trajectory estimation from cone-beam computed tomography projections for precise setup in radiotherapy for targets with respiratory motion.

Authors:  Esben S Worm; Morten Høyer; Walther Fledelius; Jens E Nielsen; Lars P Larsen; Per R Poulsen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-05-01       Impact factor: 7.038

7.  Radiation Therapy Workflow and Dosimetric Analysis from a Phase 1/2 Trial of Noninvasive Cardiac Radioablation for Ventricular Tachycardia.

Authors:  Nels C Knutson; Pamela P Samson; Geoffrey D Hugo; S Murty Goddu; Francisco J Reynoso; James A Kavanaugh; Sasa Mutic; Kaitlin Moore; Jessica Hilliard; Phillip S Cuculich; Clifford G Robinson
Journal:  Int J Radiat Oncol Biol Phys       Date:  2019-04-16       Impact factor: 7.038

8.  Noninvasive stereotactic radioablation for the treatment of atrial fibrillation: First-in-man experience.

Authors:  Pierre C Qian; Jose R Azpiri; Jose Assad; Eric Noel Gonzales Aceves; Carlos Erick Cardona Ibarra; Cuauhtemoc de la Pena; Miguel Hinojosa; Doug Wong; Thomas Fogarty; Patrick Maguire; Alice Jack; Edward A Gardner; Paul C Zei
Journal:  J Arrhythm       Date:  2019-12-03

9.  Rescue procedure for an electrical storm using robotic non-invasive cardiac radio-ablation.

Authors:  Raphaël Jumeau; Mahmut Ozsahin; Juerg Schwitter; Véronique Vallet; Frédéric Duclos; Michele Zeverino; Raphaël Moeckli; Etienne Pruvot; Jean Bourhis
Journal:  Radiother Oncol       Date:  2018-05-09       Impact factor: 6.280

10.  Global, regional, and national age-sex specific all-cause and cause-specific mortality for 240 causes of death, 1990-2013: a systematic analysis for the Global Burden of Disease Study 2013.

Authors: 
Journal:  Lancet       Date:  2014-12-18       Impact factor: 79.321

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.