Literature DB >> 34312919

Five-year patency for the no-touch saphenous vein and the left internal thoracic artery in on- and off-pump coronary artery bypass grafting.

Mikael Arbeus1, Domingos Souza1, Håkan Geijer2, Mats Lidén2, Bruno Pinheiro3, Lennart Bodin4, Ninos Samano5.   

Abstract

BACKGROUND: Randomized trials show high long-term patency for no-touch saphenous vein grafts in coronary artery bypass grafting. The patency rate in off-pump coronary bypass surgery for these grafts has not been investigated. Our center participated in the CORONARY randomized trial, NCT00463294. This is a study aimed to assess the patency of no-touch saphenous veins in on- versus off-pump coronary bypass surgery at five-year follow-up.
METHODS: Fifty-six patients were included. Forty of 49 patients, alive at 5 years, participated in this follow-up. There were 21 and 19 patients in the on- and off-pump groups respectively. No-touch saphenous veins were used to bypass all targets and in some cases the left anterior descending artery. Graft patency according to distal anastomosis was evaluated with computed tomography angiography.
RESULTS: The five-year patency rate was 123/139 (88.5%). The patency for the no-touch vein grafts was 57/64 (89.1%) in the on-pump versus 37/45 (82.2%) in the off-pump group. All left internal thoracic arteries except for one, 29/30 (96.6%), were patent. All vein grafts used to bypass the left anterior descending and the diagonal arteries were patent 32/32. The lowest patency rate for the saphenous veins was to the right coronary territory, particularly in off-pump surgery (80.0% vs. 62.5% for the on- respective off-pump groups).
CONCLUSIONS: Comparable 5-year patency for the no-touch saphenous veins and the left internal thoracic arteries to the left anterior descending territory in both on- and off-pump coronary artery bypass grafting. Graft patency in off-pump CABG is lower to the right coronary artery.
© 2021 The Authors. Journal of Cardiac Surgery Published by Wiley Periodicals LLC.

Entities:  

Keywords:  coronary artery bypass grafting; no-touch; off-pump; patency; saphenous veins

Mesh:

Year:  2021        PMID: 34312919     DOI: 10.1111/jocs.15853

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  1 in total

1.  The "No-touch" Harvesting Technique Revives the Position of the Saphenous Vein as an Important Conduit in CABG Surgery: 30-year Anniversary.

Authors:  Bruno Botelho Pinheiro; Michael Dashwood; Domingos S R Souza
Journal:  Braz J Cardiovasc Surg       Date:  2021-10-17
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.