Literature DB >> 34303831

NUDIM: A non-uniform fast Fourier transform based dual-space constraint iterative reconstruction method in biological electron tomography.

Zhi Geng1, Zhun She1, Qiang Zhou2, Zheng Dong2, Fei Zhan3, Heng Zhang1, Jianhua Xu1, Zengqiang Gao4, Yuhui Dong5.   

Abstract

Electron tomography, a powerful imaging tool for studying 3D structures of macromolecular assemblies, always suffers from imperfect reconstruction with limited resolution due to the intrinsic low signal-to-noise ratio (SNR) and inaccessibility to certain tilt angles induced by radiation damage or mechanical limitation. In order to compensate for such insufficient data with low SNR and further improve imaging resolution, prior knowledge constraints about the objects in both real space and reciprocal space are thus exploited during tomographic reconstruction. However, direct Fast Fourier transform (FFT) between real space and reciprocal space remains extraordinarily challenging owing to their inconsistent grid sampling modes, e.g. regular and uniform grid sampling in real space whereas radial or polar grid sampling in reciprocal space. In order to solve such problem, a technique of non-uniform fast Fourier transform (NFFT) has been developed to transform efficiently between non-uniformly sampled grids in real and reciprocal space with sufficient accuracy. In this work, a Non-Uniform fast Fourier transform based Dual-space constraint Iterative reconstruction Method (NUDIM) applicable to biological electron tomography is proposed with a combination of basic concepts from equally sloped tomography (EST) and NFFT based reconstruction. In NUDIM, the use of NFFT can circumvent such grid sampling inconsistency and thus alleviate the stringent equally-sloped sampling requirement in EST reconstruction, while the dual-space constraint iterative procedure can dramatically enhance reconstruction quality. In comparison with conventional reconstruction methods, NUDIM is numerically and experimentally demonstrated to produce superior reconstruction quality with higher contrast, less noise and reduced missing wedge artifacts. More importantly, it is also capable of retrieving part of missing information from a limited number of projections.
Copyright © 2021 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Dual-space constraint iterative method; Electron tomography; Non-uniform Fast Fourier Transfrom

Mesh:

Year:  2021        PMID: 34303831     DOI: 10.1016/j.jsb.2021.107770

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  1 in total

1.  Compressed sensing for electron cryotomography and high-resolution subtomogram averaging of biological specimens.

Authors:  Jan Böhning; Tanmay A M Bharat; Sean M Collins
Journal:  Structure       Date:  2022-01-19       Impact factor: 5.006

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.