Estimating the Accuracy of Mandible Anatomical Models Manufactured Using Material Extrusion Methods.

Paweł Turek1, Grzegorz Budzik1.   

Abstract

The development of new solutions in craniofacial surgery brings the need to increase the accuracy of 3D printing models. The accuracy of the manufactured models is most often verified using optical coordinate measuring systems. However, so far, no decision has been taken regarding which type of system would allow for a reliable estimation of the geometrical accuracy of the anatomical models. Three types of optical measurement systems (Atos III Triple Scan, articulated arm (MCA-II) with a laser head (MMD × 100), and Benchtop CT160Xi) were used to verify the accuracy of 12 polymer anatomical models of the left side of the mandible. The models were manufactured using fused deposition modeling (FDM), melted and extruded modeling (MEM), and fused filament fabrication (FFF) techniques. The obtained results indicate that the Atos III Triple Scan allows for the most accurate estimation of errors in model manufacturing. Using the FDM technique obtained the best accuracy in models manufactured (0.008 ± 0.118 mm for ABS0-M30 and 0.016 ± 0.178 mm for PC-10 material). A very similar value of the standard deviation of PLA and PET material was observed (about 0.180 mm). The worst results were observed in the MEM technique (0.012 mm ± 0.308 mm). The knowledge regarding the precisely evaluated errors in manufactured models within the mandibular area will help in the controlled preparation of templates regarding the expected accuracy of surgical operations.

Entities:  

Keywords:  accuracy; additive manufacturing; mandible; material extrusion methods; optical systems; polymer models

Year:  2021        PMID: 34301029     DOI: 10.3390/polym13142271

Source DB:  PubMed          Journal:  Polymers (Basel)        ISSN: 2073-4360            Impact factor:   4.329


  2 in total

1.  Manufacturing Polymer Model of Anatomical Structures with Increased Accuracy Using CAx and AM Systems for Planning Orthopedic Procedures.

Authors:  Paweł Turek; Damian Filip; Łukasz Przeszłowski; Artur Łazorko; Grzegorz Budzik; Sławomir Snela; Mariusz Oleksy; Jarosław Jabłoński; Jarosław Sęp; Katarzyna Bulanda; Sławomir Wolski; Andrzej Paszkiewicz
Journal:  Polymers (Basel)       Date:  2022-05-31       Impact factor: 4.967

2.  Procedure Increasing the Accuracy of Modelling and the Manufacturing of Surgical Templates with the Use of 3D Printing Techniques, Applied in Planning the Procedures of Reconstruction of the Mandible.

Authors:  Paweł Turek; Paweł Pakla; Grzegorz Budzik; Bogumił Lewandowski; Łukasz Przeszłowski; Tomasz Dziubek; Sławomir Wolski; Jan Frańczak
Journal:  J Clin Med       Date:  2021-11-25       Impact factor: 4.241