J A Sorenson1, C R Mitchell, J D Armstrong, H Mann, D G Bragg, F A Mann, I B Tocino, M M Wojtowycz.
Abstract
We evaluated the effects of unsharp masking and highly efficient scatter rejection on film-screen chest radiographs of cancer patients. Unsharp masking significantly improved the detectability of lung nodules and visibility of anatomic structures in poorly penetrated areas of the chest. Highly efficient scatter rejection by an improved antiscatter grid provided only modest additional benefits. The study supports the conclusion that nodule detection in poorly penetrated areas on conventional chest radiographs is limited primarily by display contrast, whereas in the well-penetrated lung fields it is limited primarily by confusing background structures, rather than inadequate contrast. A method for analyzing clinical nodule detection data by transforming the FROC data to ROC coordinates also is demonstrated.Entities:
Mesh:
Year: 1987 PMID: 3429172 DOI: 10.1097/00004424-198710000-00002
Source DB: PubMed Journal: Invest Radiol ISSN: 0020-9996 Impact factor: 6.016