| Literature DB >> 34290974 |
Fan Xu1, Yingying Liang2, Wei Guo3, Zhiping Liang1, Liqi Li1, Yuchao Xiong1, Guoxi Ye1, Xuwen Zeng1.
Abstract
OBJECTIVES: To assess the diagnostic accuracy of diffusion-weighted imaging (DWI) in predicting the malignant potential in patients with intraductal papillary mucinous neoplasms (IPMNs) of the pancreas.Entities:
Keywords: DWI; diagnosis; intraductal papillary mucinous neoplasms; meta-analysis; pancreas
Year: 2021 PMID: 34290974 PMCID: PMC8287206 DOI: 10.3389/fonc.2021.637681
Source DB: PubMed Journal: Front Oncol ISSN: 2234-943X Impact factor: 6.244
Figure 1Flowchart showing selection process for meta-analysis.
Study characteristics of the included studies.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| standard | ||||||||||||
| mean (range) | ||||||||||||
| standard (mean, range, days) | ||||||||||||
| Zhang ( | 2016 | China | 2010.1-2015.6 | R | NA | Yes | 1 (10) | 61.95 (NA) | 42 (25/17) | 42 (25/17) | Histopathology | 7 (2–12) |
| (surgery) | ||||||||||||
| Kang ( | 2014 | Korea | 2010.6-2012.7 | R | NA | Yes | 1 (3) | NA | 37 (NA) | 37 (22/15) | Histopathology | 10 (0–64) |
| (surgery) | ||||||||||||
| Kim ( | 2017 | Korea | 2013.8-2015.6 | R | NA | Yes | 2 (16/6) | NA | 132 (83/49) | 132 (83/49) | Histopathology | 14.5 (1–31) |
| (surgery) | ||||||||||||
| Ogawa ( | 2014 | Japan | 2005.6-2013.1 | R | NA | Yes | 2 (NA) | 68 (NA) | 35 (23/12) | 35 (13/22) | Histopathology | NA (NA) |
| (surgery) | ||||||||||||
| Jang ( | 2014 | Korea | 2008.1-2013.7 | R | Consecutive | Yes | 2 (13/3) | 25.6 (35–83) | 61 (34/27) | 61 (42/19) | Histopathology | 30 (NA) |
| (surgery) |
M/F, male/female; R, retrospective; B, benign; M, malignant; NA, not available.
MRI characteristics of the included studies.
|
|
|
|
|
|
| |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Vendor | Model | DWI sequence | Respiration | b values for ADC maps (s/mm2) | Slice thickness (mm) | Diffusion restriction (yes/no) | ADC cut-off value (× 10-3) (mm2/s) | |||
| Zhang | Siemens | Magnetom Avanto; | 1.5 | NA | single-shot, echo-planar sequence | NA | 0; 500 | 7 | NA | 2.66 |
| Kang | Siemens | Magnetom Avanto; | 3.0 | 32-channel phased-array coil | single-shot escho-planar | Free-breathing | 0, 25, 50, 75, 100, 150, 200, 500, 800, 1,000 | 7 | NA | 1.99 |
| Kim | Philips | Intera Achieva | 3.0 | 16-channel phased-array receiver coil | single-shot escho-planar | Respiratory-triggered | 0, 100, 800 | 5 | Yes | NA |
| Ogawa | Toshiba | EXCELART Vantage | 1.5 | NA | single-shot escho-planar | Respiratory-triggered | 0, 1,000 | 7 | Yes | 2.71 |
| Jang | Philips | Intera Achieva | 3.0 | 16-channel phased-array (torso or cardiac) coil | single-shot escho-planar | Respiratory-triggered | 0, 100, 800 | 5 | Yes | NA |
DWI, diffusion-weighted imaging; ADC, apparent diffusion coefficient; NA, not available.
Figure 2Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) criteria for the five included studies.
Figure 3Coupled forest plots of pooled sensitivity and specificity. Numbers are pooled estimates with 95% confidence intervals (CIs) in parentheses and horizontal lines indicate 95% CIs.
Figure 4The summary receiver operating characteristic (SROC) curve of the diagnostic performance of DWI for differentiating malignant from benign IPMNs of the pancreas.
Figure 5Deeks’ funnel plot used to evaluate potential publication bias.
Results of the meta-regression analysis of DWI for discriminating benign and malignant IPMN.
| Covariates | Subgroup | Studies (n) | Meta-analytic summary estimates | |||
|---|---|---|---|---|---|---|
| Sensitivity | P | Specificity | p | |||
| (95% CI) | ||||||
| (95% CI) | ||||||
| Study enrollment | Consecutive enrollment | 1 | 0.79 (0.59–0.99) | 0.82 | 0.82 (0.54–1.00) | 0.36 |
| NA | 5 | 0.73 (0.64–0.82) | 0.95 (0.88–1.00) | |||
| Reader experience | Available | 4 | 0.73 (0.62–0.83) | 0.13 | 0.95 (0.85–1.00) | 0.32 |
| NA | 2 | 0.78 (0.63–0.92) | 0.95 (0.83–1.00) | |||
| Number of readers | n = 1 | 4 | 0.78 (0.70–0.85) | 0.81 | 0.86 (0.81–0.92) | 0.07 |
| n = 2 | 2 | 0.66 (0.49–0.82) | 1.00 (1.00–1.00) | |||
| Magnetic strength | 1.5T | 3 | 0.77 (0.65–0.90) | 0.11 | 0.97 (0.91–1.00) | 0.71 |
| 3T | 3 | 0.72 (0.60–0.85) | 0.91 (0.79–1.00) | |||
| Max value of b value | ≥1,000 | 3 | 0.77 (0.67–0.87) | 0.05 | 0.90 (0.78–1.00) | 0.08 |
| <1,000 | 3 | 0.71 (0.58–0.84) | 0.97 (0.91–1.00) | |||
| Thickness of DWI | 5 mm | 2 | 0.78 (0.68–0.88) | 0.02* | 0.85 (0.79–0.91) | 0.19 |
| 7 mm | 4 | 0.72 (0.62–0.82) | 0.97 (0.94–1.00) | |||
| DWI parameter | quantitative DWI | 3 | 0.72 (0.60–0.84) | 0.21 | 0.97 (0.92–1.00) | 0.01* |
| qualitative DWI | 3 | 0.77 (0.68–0.85) | 0.86 (0.80–0.92) | |||
*Denotes a statistical significance.
DWI, diffusion-weighted imaging; NA, not available.