Literature DB >> 34289168

High anatomical accuracy of a novel high-resolution wide-band dielectric imaging system in cryoballoon-based ablation.

Laura Rottner1, Milena Nodorp1, Weimann Jessica1, Ruben Schleberger1, Christoph Sinning1, Marc Lemoine1, Leon Dinshaw1, Paula Münkler1, Tina Lin2, Christian Meyer1, Bruno Reissmann1, Andreas Metzner1, Andreas Rillig1.   

Abstract

PURPOSE: Recently, a novel cardiac imaging system based on a wide-band dielectric technology (KODEX-EPD) was introduced to guide catheter ablation. The aim of the study was to evaluate this 3D wide-band dielectric imaging system (WDIS) during cryoballoon (CB)-based atrial fibrillation (AF) ablation focusing on accuracy of pulmonary vein (PV)-anatomy.
METHODS: In consecutive patients with symptomatic AF, CB-based ablation was performed in conjunction with the 3D WDIS. Selective PV-angiographies were performed, and 3D anatomy of the left atrium (LA) and PVs using the 3D WDIS was created. The ostial diameters of the ipsilateral right-sided and left-sided PVs and ostial diameters of the right-/left-sided upper/lower PVs demonstrated by selective angiographies were analyzed and compared to 3D WDIS-based PV visualization.
RESULTS: In 65 patients (42/65 (65%) male, age 65 ± 9 years, 29/65 (45%) paroxysmal AF) a total of 260 PVs were identified. Median ostial PV-diameters for the ipsilateral left- and right-sided PVs were 38 [34; 43] and 37 [34; 40.3] mm when assessed fluoroscopically and 40 [35.7; 43] and 39 [35.0; 43] mm as demonstrated by 3D WDIS. There was no statistically significant difference between both methods regarding PV-diameter measurements. KODEX-EPD overestimated fluoroscopy measurements by 1.08 mm (95% limits of agreement of -1.93 mm and 4.1 mm).
CONCLUSION: The novel wide-band dielectric 3D-imaging system is feasible to create high-resolution images of cardiac structures during CB ablation procedures and accurately visualizes PV-anatomy.
© 2021 The Authors. Pacing and Clinical Electrophysiology published by Wiley Periodicals LLC.

Entities:  

Keywords:  CB-based PVI; PV-visualization; atrial fibrillation; catheter ablation; novel imaging system

Mesh:

Year:  2021        PMID: 34289168     DOI: 10.1111/pace.14324

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

Review 1.  Cryoballoon ablation for atrial fibrillation: Effects on neuromodulation.

Authors:  Alvise Del Monte; Luigi Pannone; Antonio Bisignani; Thiago G Osório; Saverio Iacopino; Gian-Battista Chierchia; Carlo de Asmundis
Journal:  Front Cardiovasc Med       Date:  2022-07-28

2.  Cryoballoon ablation guided by a novel wide-band dielectric imaging system.

Authors:  Laura Rottner; Julius Obergassel; Ilaria My; Paulus Kirchhof; Feifan Ouyang; Bruno Reissmann; Andreas Metzner; Andreas Rillig
Journal:  Front Cardiovasc Med       Date:  2022-08-09

3.  Anatomical accuracy of the KODEX-EPD novel 3D mapping system of the left atrium during pulmonary vein isolation: A correlation with computer tomography imaging.

Authors:  Oholi Tovia Brodie; Moshe Rav-Acha; Arik Wolak; Michael Ilan; David J Orenstein; Shalom Abuhatzera; Michael Glikson; Yoav Michowitz
Journal:  J Cardiovasc Electrophysiol       Date:  2022-02-22       Impact factor: 2.942

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.