Literature DB >> 34282228

Mechanical properties of CAD/CAM-fabricated in comparison to conventionally fabricated functional regulator 3 appliances.

Christoph Roser1, Lutz D Hodecker2, Chris Koebel2, Christopher J Lux2, Dorothee Ruckes3, Stefan Rues3, Andreas Zenthöfer3.   

Abstract

Manufacturing of Fränkel's functional regulator 3 (FR3) is complicated and requires extensive knowledge from the dental technician. To determine whether FR3s produced by CAD/CAM techniques (CAD-FR3) meet similar mechanical properties like conventional FR3s (Con-FR3), for each of 10 patient cases, three CAD-FR3 designs (palatal connector cross-section 3 × 3 mm, 4 × 1 mm or 5 × 2 mm) and one Con-FR3 were subjected to cyclic loading and subsequent fracture testing in a universal testing device. Transversal load capacity (Fmax(FR3)) and stiffness were compared among the different CAD-FR3 designs and Con-FR3s using Friedman and Wilcoxon tests with a significance level of α = 0.05. All CAD-FR3 designs had significantly higher mean Fmax(FR3) (p ≤ 0.007) and stiffness (p ≤ 0.005) than the Con-FR3s. The CAD-FR33×3 had the highest mean Fmax(FR3) (98.2 ± 26.2 N) and stiffness (37.1 ± 15.5 N/mm), closely followed by the CAD-FR35×2 (Fmax(FR3): 90.3 ± 24.7 N; stiffness: 30.0 ± 12.3 N/mm). Among the CAD appliances, CAD-FR34×1 had the lowest values (p ≤ 0.007 for all pairwise tests) with Fmax(FR3) of 45.8 ± 17.9 N and stiffness of 12.5 ± 7.3 N/mm. CAD-FR3s have superior mechanical properties in comparison to Con-FR3s if certain design parameters are followed. Further clinical investigations have to examine if they can serve as an alternative in practice.
© 2021. The Author(s).

Entities:  

Year:  2021        PMID: 34282228     DOI: 10.1038/s41598-021-94237-x

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  16 in total

1.  A new approach to restorative dentistry: fabricating ceramic restorations using CEREC CAD/CAM.

Authors:  D Estafan; A David; S David; J Calamia
Journal:  Compend Contin Educ Dent       Date:  1999-06

2.  Precision of implementing virtual setups for orthodontic treatment using CAD/CAM-fabricated custom archwires.

Authors:  Ralf Müller-Hartwich; Paul-Georg Jost-Brinkmann; Katharina Schubert
Journal:  J Orofac Orthop       Date:  2016-01-11       Impact factor: 1.938

3.  Computer-assisted milling of dental restorations using a new CAD/CAM data acquisition system.

Authors:  J Willer; A Rossbach; H P Weber
Journal:  J Prosthet Dent       Date:  1998-09       Impact factor: 3.426

4.  Methodological accuracy of digital and manual model analysis in orthodontics - A retrospective clinical study.

Authors:  Carsten Lippold; Christian Kirschneck; Kristina Schreiber; Saleh Abukiress; Amir Tahvildari; Tatjana Moiseenko; Gholamreza Danesh
Journal:  Comput Biol Med       Date:  2015-04-17       Impact factor: 4.589

5.  Artificial intelligence in orthodontics : Evaluation of a fully automated cephalometric analysis using a customized convolutional neural network.

Authors:  Felix Kunz; Angelika Stellzig-Eisenhauer; Florian Zeman; Julian Boldt
Journal:  J Orofac Orthop       Date:  2019-12-18       Impact factor: 1.938

6.  A comparative study of two different clear aligner systems.

Authors:  Federica Ercoli; Michele Tepedino; Vincenzo Parziale; Cesare Luzi
Journal:  Prog Orthod       Date:  2014-05-02       Impact factor: 2.750

7.  Effectiveness of clear aligner therapy for orthodontic treatment: A systematic review.

Authors:  Lindsay Robertson; Harsimrat Kaur; Nathalia Carolina Fernandes Fagundes; Dan Romanyk; Paul Major; Carlos Flores Mir
Journal:  Orthod Craniofac Res       Date:  2019-11-13       Impact factor: 1.826

8.  Effectiveness, efficiency and adverse effects of using direct or indirect bonding technique in orthodontic patients: a systematic review and meta-analysis.

Authors:  Yanxi Li; Li Mei; Jieya Wei; Xinyu Yan; Xu Zhang; Wei Zheng; Yu Li
Journal:  BMC Oral Health       Date:  2019-07-08       Impact factor: 2.757

9.  Debonding force and shear bond strength of an array of CAD/CAM-based customized orthodontic brackets, placed by indirect bonding- An In Vitro study.

Authors:  Ha-Na Sha; Sung-Hwan Choi; Hyung-Seog Yu; Chung-Ju Hwang; Jung-Yul Cha; Kwang-Mahn Kim
Journal:  PLoS One       Date:  2018-09-11       Impact factor: 3.240

10.  Evaluation of magnetic resonance imaging artifacts caused by fixed orthodontic CAD/CAM retainers-an in vitro study.

Authors:  Christoph Roser; Tim Hilgenfeld; Sinan Sen; Tobias Badrow; Sebastian Zingler; Sabine Heiland; Martin Bendszus; Christopher J Lux; Alexander Juerchott
Journal:  Clin Oral Investig       Date:  2020-08-12       Impact factor: 3.573

View more