A novel partially covered metallic stent with a 20-mm long distal bare portion for EUS-guided hepaticogastrostomy.

Satoshi Asai1, Kotaro Takeshita1, Takumi Ichinona1, Eisuke Akamine1, Naoki Fujimoto1.   

Abstract

Video 1EUS-guided hepaticogastrostomy with a novel partially covered self-expandable metallic stent for a patient with biliary obstruction owing to gallbladder cancer.
© 2021 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc.

Entities:  

Keywords:  EUS-HGS, endoscopic ultrasonography-guided hepaticogastrostomy; PCSEMS, partially covered self-expandable metallic stent; SEMS, self-expandable metallic stent

Year:  2021        PMID: 34278097      PMCID: PMC8270758          DOI: 10.1016/j.vgie.2021.03.007

Source DB:  PubMed          Journal:  VideoGIE        ISSN: 2468-4481


Endoscopic ultrasonography-guided hepaticogastrostomy (EUS-HGS) is a widely performed procedure for biliary drainage after failed endoscopic retrograde cholangiopancreatography. There are several steps in EUS-HGS, including puncture, guidewire advancement, and fistula dilation. Among these steps, stent selection is one of the most critical to obtain satisfactory short and long-term outcomes. Currently, plastic stents and self-expandable metallic stents (SEMSs) are used for EUS-HGS; however, plastic stents have an increased risk of bile leakage and periprocedural bleeding compared to SEMSs; thus, SEMSs are recommended for EUS-guided biliary drainage. Although only a fully covered SEMS has the advantage of removability, it may block the intrahepatic biliary branch, causing segmental cholangitis. A partially covered SEMS (PCSEMS) with a long bare portion at its distal end can minimize this risk; however, a conventional PCSEMS only has a 5-mm bare portion. In EUS-HGS, the stent length in the intrahepatic bile duct should be at least 20 mm to prevent stent migration. Thus, although a PCSEMS is used, a covered portion of 15 mm or more should be deployed in the intrahepatic bile duct, which might cause segmental cholangitis. Recently, a novel PCSEMS (EGIS biliary stent, double covered, 8 mm × 12 cm; S&G Biotech Inc, Yongin-si, Korea) with a 20-mm bare distal portion has been developed to avoid blocking biliary side branches. Compared with other general commercially available PCSEMSs, the bare length on its distal end is long enough to prevent intrahepatic bile duct obstruction. This stent has radio-opaque markers located at 3 positions (Fig. 1). The second markers, located at the junction of the bare and covered portions 20 mm from the distal end, help in stent deployment. When deploying the PCSEMS, the stent is first released up to 20 mm (Fig. 2A). Subsequently, the delivery sheath is pulled until the second markers are positioned at the puncture site of the bile duct (Fig. 2B), followed by complete deployment holding the markers in the same position. A stent length ≥3 cm in the luminal portion is reportedly suitable for maintaining stent patency. Moreover, to avoid the potential adverse event of stent migration from the stomach into the peritoneal cavity, the stent length should be ≥10 cm,, and the intrascope channel stent release technique is likely to be useful.
Figure 1

Stent specifications (EGIS biliary stent, double covered; S&G Biotech Inc, Yongin-si, Korea).

Figure 2

Illustration of stent deployment. A, The stent is released up to 20 mm. B, The delivery sheath is pulled until the second markers are positioned at the puncture site of the bile duct.

Stent specifications (EGIS biliary stent, double covered; S&G Biotech Inc, Yongin-si, Korea). Illustration of stent deployment. A, The stent is released up to 20 mm. B, The delivery sheath is pulled until the second markers are positioned at the puncture site of the bile duct. The present case report describes an 82-year-old man with gallbladder cancer. He was admitted to our hospital for obstructive jaundice. EUS-HGS was performed because the ampulla of Vater was endoscopically inaccessible owing to the previously placed duodenal stent. The B3 bile duct was punctured with a 19-gauge needle, and a 0.025-inch guidewire was sufficiently advanced after cholangiography. A PCSEMS (EGIS biliary stent, double covered, 8 mm × 12 cm; S&G Biotech Inc) was inserted into the bile duct (Fig. 3A) after fistula dilation with a 4-mm balloon. Subsequently, the stent was deployed as described (Fig. 3B), and endoscopic examination confirmed adequate stent length in the luminal portion (Fig. 4). CT immediately after the procedure showed accurate positioning of the stent without a candy sign or bile leakage (Fig. 5).
Figure 3

Fluoroscopic imaging demonstrating stent in place. A, Before releasing the stent, the second markers are placed on the deeper side of the puncture site of the bile duct. B, After deployment of the stent, the second markers are on the puncture site of the bile duct. The arrow shows the puncture site of the bile duct, and the arrowhead shows the second markers.

Figure 4

Endoscopic examination of the luminal portion of the stent.

Figure 5

CT showing accurate positioning of the stent without candy sign or bile leakage.

Fluoroscopic imaging demonstrating stent in place. A, Before releasing the stent, the second markers are placed on the deeper side of the puncture site of the bile duct. B, After deployment of the stent, the second markers are on the puncture site of the bile duct. The arrow shows the puncture site of the bile duct, and the arrowhead shows the second markers. Endoscopic examination of the luminal portion of the stent. CT showing accurate positioning of the stent without candy sign or bile leakage. In conclusion, this novel PCSEMS could provide stable and easy stent deployment in EUS-HGS without blocking the intrahepatic biliary branch, owing to the 20-mm-long distal bare portion. However, additional studies are required to further validate the use of this stent (Video 1, available online at www.giejournal.org).

Disclosure

All authors disclosed no financial relationships.
  5 in total

1.  Clinical Impact of the Intra-scope Channel Stent Release Technique in Preventing Stent Migration During EUS-Guided Hepaticogastrostomy.

Authors:  Akira Miyano; Takeshi Ogura; Kazuhiro Yamamoto; Atsushi Okuda; Nobu Nishioka; Kazuhide Higuchi
Journal:  J Gastrointest Surg       Date:  2018-04-17       Impact factor: 3.452

2.  Stent length is impact factor associated with stent patency in endoscopic ultrasound-guided hepaticogastrostomy.

Authors:  Takeshi Ogura; Kazuhiro Yamamoto; Tatsushi Sano; Saori Onda; Akira Imoto; Daisuke Masuda; Wataru Takagi; Shinya Fukunishi; Kazuhide Higuchi
Journal:  J Gastroenterol Hepatol       Date:  2015-12       Impact factor: 4.029

3.  Safety and effectiveness of a long, partially covered metal stent for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction.

Authors:  Yousuke Nakai; Hiroyuki Isayama; Natsuyo Yamamoto; Saburo Matsubara; Yukiko Ito; Naoki Sasahira; Ryunosuke Hakuta; Gyotane Umefune; Naminatsu Takahara; Tsuyoshi Hamada; Suguru Mizuno; Hirofumi Kogure; Minoru Tada; Kazuhiko Koike
Journal:  Endoscopy       Date:  2016-10-07       Impact factor: 10.093

4.  International multicenter comparative trial of transluminal EUS-guided biliary drainage via hepatogastrostomy vs. choledochoduodenostomy approaches.

Authors:  Mouen A Khashab; Ahmed A Messallam; Irene Penas; Yousuke Nakai; Rani J Modayil; Carlos De la Serna; Kazuo Hara; Mohamad El Zein; Stavros N Stavropoulos; Manuel Perez-Miranda; Vivek Kumbhari; Saowanee Ngamruengphong; Vinay K Dhir; Do Hyun Park
Journal:  Endosc Int Open       Date:  2016-01-15

5.  Clinical practice guidelines for safe performance of endoscopic ultrasound/ultrasonography-guided biliary drainage: 2018.

Authors:  Hiroyuki Isayama; Yousuke Nakai; Takao Itoi; Ichiro Yasuda; Hiroshi Kawakami; Shomei Ryozawa; Masayuki Kitano; Atsushi Irisawa; Akio Katanuma; Kazuo Hara; Takuji Iwashita; Naotaka Fujita; Kenji Yamao; Masahiro Yoshida; Kazuo Inui
Journal:  J Hepatobiliary Pancreat Sci       Date:  2019-06-28       Impact factor: 7.027

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.