Literature DB >> 34277218

Self-Monitoring of Blood Glucose for Patients With Type 2 Diabetes in Primary Care: A Single-Centre, 10-Year Retrospective Analysis.

Justina Cheh Juan Tai1, Liang Zhi Wong1, Adrian Richardson2.   

Abstract

Background While type 1 diabetics often require self-monitoring of blood glucose (SMBG), the evidence for tight blood glucose monitoring in non-insulin treated type 2 diabetes mellitus (T2DM) patients is limited. In addition to its lack of cost-effectiveness, unnecessary blood glucose monitoring may also result in anxiety and decreased quality of life. In this retrospective audit, we assessed SMBG prescribing practice at one general practice against guidelines from the National Institute for Health and Care Excellence (NICE). Methods A systematic search of T2DM patients diagnosed at a general practice in London, United Kingdom, in the last 10 years was undertaken. A total of 146 patients fulfilled these criteria, of which 100 patients were randomly selected for inclusion in this audit. Medical notes were reviewed and collated for analysis. Results Only 85% of patients with T2DM were being managed in accordance with the NICE guidelines on SMBG, while 15% were not. It was more common for patients who did not need monitoring to be inappropriately prescribed SMBG (10%) than it was for patients who needed monitoring to be under-prescribed SMBG (5%). The reasons for prescribing SMBG were often left undocumented. Conclusion Adherence to the NICE guidelines is subpar. Recommended solutions include educating healthcare professionals involved in the prescribing of SMBGs, regular reviews of the continued necessity of SMBG, and digital alerts on e-prescribing systems.
Copyright © 2021, Tai et al.

Entities:  

Keywords:  blood glucose; blood glucose strips; diabetes; general practice; lancets; monitoring kits; primary care; self-monitoring; type 2 diabetes mellitus

Year:  2021        PMID: 34277218      PMCID: PMC8272934          DOI: 10.7759/cureus.15597

Source DB:  PubMed          Journal:  Cureus        ISSN: 2168-8184


  19 in total

Review 1.  Self-monitoring of blood glucose levels in patients with type 2 diabetes mellitus not taking insulin: a meta-analysis.

Authors:  Ali Towfigh; Maria Romanova; Jane E Weinreb; Brett Munjas; Marika J Suttorp; Annie Zhou; Paul G Shekelle
Journal:  Am J Manag Care       Date:  2008-07       Impact factor: 2.229

2.  Meta-analysis of the benefits of self-monitoring of blood glucose on glycemic control in type 2 diabetes patients: an update.

Authors:  Nalinee Poolsup; Naeti Suksomboon; Somying Rattanasookchit
Journal:  Diabetes Technol Ther       Date:  2009-12       Impact factor: 6.118

3.  A history of blood glucose meters and their role in self-monitoring of diabetes mellitus.

Authors:  S F Clarke; J R Foster
Journal:  Br J Biomed Sci       Date:  2012       Impact factor: 3.829

4.  Meta-analysis of individual patient data in randomised trials of self monitoring of blood glucose in people with non-insulin treated type 2 diabetes.

Authors:  Andrew J Farmer; Rafael Perera; Alison Ward; Carl Heneghan; Jason Oke; Anthony H Barnett; Mayer B Davidson; Bruno Guerci; Vivien Coates; Ulrich Schwedes; Simon O'Malley
Journal:  BMJ       Date:  2012-02-27

5.  Frequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes database.

Authors:  J M Evans; R W Newton; D A Ruta; T M MacDonald; R J Stevenson; A D Morris
Journal:  BMJ       Date:  1999-07-10

Review 6.  Self-monitoring of blood glucose in type 2 diabetes: systematic review.

Authors:  C Clar; K Barnard; E Cummins; P Royle; N Waugh
Journal:  Health Technol Assess       Date:  2010-03       Impact factor: 4.014

7.  Glucose Self-monitoring in Non-Insulin-Treated Patients With Type 2 Diabetes in Primary Care Settings: A Randomized Trial.

Authors:  Laura A Young; John B Buse; Mark A Weaver; Maihan B Vu; C Madeline Mitchell; Tamara Blakeney; Kimberlea Grimm; Jennifer Rees; Franklin Niblock; Katrina E Donahue
Journal:  JAMA Intern Med       Date:  2017-07-01       Impact factor: 21.873

Review 8.  Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin.

Authors:  Uriëll L Malanda; Laura M C Welschen; Ingrid I Riphagen; Jacqueline M Dekker; Giel Nijpels; Sandra D M Bot
Journal:  Cochrane Database Syst Rev       Date:  2012-01-18

9.  Efficacy of self monitoring of blood glucose in patients with newly diagnosed type 2 diabetes (ESMON study): randomised controlled trial.

Authors:  Maurice J O'Kane; Brendan Bunting; Margaret Copeland; Vivien E Coates
Journal:  BMJ       Date:  2008-04-17

10.  Impact of self monitoring of blood glucose in the management of patients with non-insulin treated diabetes: open parallel group randomised trial.

Authors:  Andrew Farmer; Alisha Wade; Elizabeth Goyder; Patricia Yudkin; David French; Anthea Craven; Rury Holman; Ann-Louise Kinmonth; Andrew Neil
Journal:  BMJ       Date:  2007-06-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.