Intraoperative Neurophysiology and Transcranial Doppler for Detection of Cerebral Ischemia and Hyperperfusion During Carotid Endarterectomy.

Jinfeng Wang1, Lanjun Guo2, Robert N Holdefer3, Yansheng Zhang1, Qin Liu1, Qing Gai1, Wengao Zhang4.   

Abstract

OBJECTIVE: To evaluate and compare efficacy of intraoperative neurophysiological monitoring (IONM) and intraoperative transcranial Doppler (TCD) techniques for identification of hypoperfusion during carotid artery clamp and hyperperfusion after release of occlusion during carotid endarterectomy.
METHODS: This was a retrospective, consecutive case series of 152 patients undergoing carotid endarterectomy between June 2018 and March 2020. Somatosensory evoked potentials, motor evoked potentials, electroencephalogram, and TCD were obtained.
RESULTS: Three patient cohorts were observed after clamping the carotid artery: A, in 132 of 152 patients (87%), TCD blood flow velocity decreased by <50% and there were no changes in IONM; B, in 5 of 152 (3%) patients, TCD blood flow rate was reduced 50%-100% with no changes in IONM; C, in 15 patients (10%), blood flow velocity was reduced by 50%-100% and all IONM modalities met warning criteria. With increased blood pressure, IONM and blood flow velocities improved to less than warning criteria in 8 of 15 patients. In 6 of the 7 remaining patients, IONM modalities recovered to baseline immediately after clamps were removed from the carotid artery. The 1 patient with persistent motor evoked potential deterioration experienced postoperative proximal muscle weakness, which recovered 48 hours later. In 22 patients, TCD detected hyperperfusion at the moment of clamp release.
CONCLUSIONS: TCD blood flow velocity is correlated with motor evoked potential and somatosensory evoked potential amplitude changes after clamping. After declamping, TCD can detect hyperperfusion and help regulate blood pressure to prevent hyperperfusion.
Copyright © 2021 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Carotid endarterectomy; Hyperperfusion; Intraoperative neurophysiological monitoring; Ischemia; Stroke; Transcranial Doppler sonography

Mesh:

Year:  2021        PMID: 34271149     DOI: 10.1016/j.wneu.2021.07.023

Source DB:  PubMed          Journal:  World Neurosurg        ISSN: 1878-8750            Impact factor:   2.104


  1 in total

Review 1.  Multimodality Monitoring for Delayed Cerebral Ischemia in Subarachnoid Hemorrhage: A Mini Review.

Authors:  Collin Labak; Berje Haroutuon Shammassian; Xiaofei Zhou; Ayham Alkhachroum
Journal:  Front Neurol       Date:  2022-04-13       Impact factor: 4.086

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.