Patient-tailored Contrast Delivery Protocols for Computed Tomography Coronary Angiography: Lower Contrast Dose and Better Image Quality.

Thomas P W van den Boogert1, Ricardo R Lopes, Nick H J Lobe, Tim A Verwest, Jaap Stoker, José P Henriques, Henk A Marquering, R Nils Planken.   

Abstract

PURPOSE: The first objective of this study was to evaluate the efficacy of a patient-tailored contrast delivery protocol for coronary computed tomography angiography (CTCA), in terms of diagnostic coronary attenuation and total iodine load (TIL), by adjusting the iodine delivery rate (IDR) via dilution for body weight and tube voltage (kV), as compared with a protocol with a fixed bolus of contrast in a clinical setting. The secondary objective was to assess the association between the test-bolus data and luminal attenuation in CTCA.
MATERIALS AND METHODS: Patients who underwent CTCA with fixed IDR contrast delivery (cohort 1) or with IDR adjusted for body weight and kV settings (70 to 120 kV) (cohort 2) were included, and compared for intravascular luminal attenuation and TIL. The association between intravascular luminal attenuation and test-bolus scan data was investigated with linear regression.
RESULTS: In cohort 1 (176 patients), the mean luminal attenuation differed markedly between kV categories, whereas in cohort 2 (154 patients), there were no marked differences. The mean TIL reduced significantly (20.1±1.2 g in cohort 1, 17.7±3.0 g in cohort 2, P<0.001). The peak height of the test-bolus scan was independently associated with luminal attenuation in the ascending aorta, with a 0.58 HU increase per HU peak-height increase (SE=0.18, P<0.001).
CONCLUSION: Clinical implementation of a patient-tailored contrast delivery protocol for CTCA, adjusted for body weight and kV, improves luminal attenuation and significantly reduces the TIL. The peak height of the test-bolus scan is associated with luminal attenuation in the ascending aorta in the CTCA scan.
Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.

Entities:  

Year:  2021        PMID: 34269752     DOI: 10.1097/RTI.0000000000000593

Source DB:  PubMed          Journal:  J Thorac Imaging        ISSN: 0883-5993            Impact factor:   3.000


  1 in total

1.  Machine learning-based prediction of insufficient contrast enhancement in coronary computed tomography angiography.

Authors:  H A Marquering; R N Planken; R R Lopes; T P W van den Boogert; N H J Lobe; T A Verwest; J P S Henriques
Journal:  Eur Radiol       Date:  2022-06-16       Impact factor: 7.034

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.