Literature DB >> 34260357

An Integrated 2D Ultrasound Phased Array Transmitter in CMOS With Pixel Pitch-Matched Beamforming.

Tiago Costa, Chen Shi, Kevin Tien, Jeffrey Elloian, Filipe A Cardoso, Kenneth L Shepard.   

Abstract

Emerging non-imaging ultrasound applications, such as ultrasonic wireless power delivery to implantable devices and ultrasound neuromodulation, require wearable form factors, millisecond-range pulse durations and focal spot diameters approaching 100 μm with electronic control of its three-dimensional location. None of these are compatible with typical handheld linear array ultrasound imaging probes. In this work, we present a 4 mm × 5 mm 2D ultrasound phased array transmitter with integrated piezoelectric ultrasound transducers on complementary metal-oxide-semiconductor (CMOS) integrated circuits, featuring pixel-level pitch-matched transmit beamforming circuits which support arbitrary pulse duration. Our direct integration method enabled up to 10 MHz ultrasound arrays in a patch form-factor, leading to focal spot diameter of ∼200 μm, while pixel pitch-matched beamforming allowed for precise three-dimensional positioning of the ultrasound focal spot. Our device has the potential to provide a high-spatial resolution and wearable interface to both powering of highly-miniaturized implantable devices and ultrasound neuromodulation.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 34260357     DOI: 10.1109/TBCAS.2021.3096722

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  4 in total

Review 1.  Circuits on miniaturized ultrasound imaging system-on-a-chip: a review.

Authors:  Jaemyung Lim
Journal:  Biomed Eng Lett       Date:  2022-05-12

2.  Design and Optimization of Ultrasonic Links With Phased Arrays for Wireless Power Transmission to Biomedical Implants.

Authors:  Zeinab Kashani; Sheikh Jawad Ilham; Mehdi Kiani
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2022-05-09       Impact factor: 5.234

3.  Design and Optimization of Ultrasound Phased Arrays for Large-Scale Ultrasound Neuromodulation.

Authors:  Sheikh Jawad Ilham; Zeinab Kashani; Mehdi Kiani
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2022-02-17       Impact factor: 3.833

4.  Enhancing AlN PMUTs' Acoustic Responsivity within a MEMS-on-CMOS Process.

Authors:  Eyglis Ledesma; Ivan Zamora; Arantxa Uranga; Francesc Torres; Núria Barniol
Journal:  Sensors (Basel)       Date:  2021-12-17       Impact factor: 3.576

  4 in total