Literature DB >> 34259877

Multiplexing neurochemical detection with carbon fiber multielectrode arrays using fast-scan cyclic voltammetry.

Harmain Rafi1,2, Alexander G Zestos3,4.   

Abstract

Carbon fiber microelectrodes (CFMEs) have been extensively used to measure neurotransmitters with fast-scan cyclic voltammetry (FSCV) due to their ability to adsorb cationic monoamine neurotransmitters. Although FSCV, in tandem with CFMEs, provides high temporal and spatial resolution, only single-channel potentiostats and electrodes have been primarily utilized. More recently, the need and use of carbon fiber multielectrode arrays has risen to target multiple brain regions. Previous studies have shown the ability to detect dopamine using multielectrode arrays; however, they are not readily available to the scientific community. In this work, we interfaced a carbon fiber multielectrode array (MEA or multielectrode array), to a commercially available four-channel potentiostat for multiplexing neurochemical measurements. The MEA's relative performance was compared to single CFMEs where dopamine detection was found to be adsorption controlled to the electrode's surface. Multiple waveforms were applied to each fiber of the multielectrode array simultaneously to detect different analytes on each electrode of the array. A proof of concept ex vivo experiment showed that the multielectrode array could record redox activity in different areas within the mouse caudate putamen and detect dopamine in a 3-mm2 area. To our knowledge, this is the first use of the multielectrode array paired with a commercially available multichannel potentiostat for multi-waveform application and neurotransmitter co-detection. This novel array may aid in future studies to better understand complex brain heterogeneity, the dynamic neurochemical environment, and how disease states or drugs affect separate brain areas concurrently. Graphical abstract.
© 2021. Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Carbon fiber; FSCV; Microelectrodes; Neurotransmitters

Mesh:

Substances:

Year:  2021        PMID: 34259877      PMCID: PMC8551007          DOI: 10.1007/s00216-021-03526-x

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  42 in total

1.  Carbon nanofiber multiplexed array and Wireless Instantaneous Neurotransmitter Concentration Sensor for simultaneous detection of dissolved oxygen and dopamine.

Authors:  Michael P Marsh; Jessica E Koehne; Russell J Andrews; M Meyyappan; Kevin E Bennet; Kendall H Lee
Journal:  Biomed Eng Lett       Date:  2012-12-01

2.  The ex vivo isolated skeletal microvessel preparation for investigation of vascular reactivity.

Authors:  Joshua T Butcher; Adam G Goodwill; Jefferson C Frisbee
Journal:  J Vis Exp       Date:  2012-04-28       Impact factor: 1.355

Review 3.  Fundamentals of fast-scan cyclic voltammetry for dopamine detection.

Authors:  B Jill Venton; Qun Cao
Journal:  Analyst       Date:  2020-02-17       Impact factor: 4.616

4.  Microfabricated FSCV-compatible microelectrode array for real-time monitoring of heterogeneous dopamine release.

Authors:  Matthew K Zachek; Jinwoo Park; Pavel Takmakov; R Mark Wightman; Gregory S McCarty
Journal:  Analyst       Date:  2010-05-13       Impact factor: 4.616

5.  High concentrations of KCl release noradrenaline from noradrenergic neurons in the rat anococcygeus muscle.

Authors:  C B L Araujo; L M Bendhack
Journal:  Braz J Med Biol Res       Date:  2002-12-19       Impact factor: 2.590

6.  Polymer Modified Carbon Fiber-Microelectrodes and Waveform Modifications Enhance Neurotransmitter Metabolite Detection.

Authors:  Dilpreet Raju; Alexander Mendoza; Pauline Wonnenberg; Sanuja Mohanaraj; Mulugeta Sarbanes; Carly Truong; Alexander G Zestos
Journal:  Anal Methods       Date:  2019-02-19       Impact factor: 2.896

7.  Scalable Nanostructured Carbon Electrode Arrays for Enhanced Dopamine Detection.

Authors:  Silvia Demuru; Luca Nela; Nathan Marchack; Steven J Holmes; Damon B Farmer; George S Tulevski; Qinghuang Lin; Hariklia Deligianni
Journal:  ACS Sens       Date:  2018-03-15       Impact factor: 7.711

8.  Characterization of flexible ECoG electrode arrays for chronic recording in awake rats.

Authors:  John D Yeager; Derrick J Phillips; David M Rector; David F Bahr
Journal:  J Neurosci Methods       Date:  2008-07-03       Impact factor: 2.390

9.  In Vivo Electrochemical Analysis of a PEDOT/MWCNT Neural Electrode Coating.

Authors:  Nicolas A Alba; Zhanhong J Du; Kasey A Catt; Takashi D Y Kozai; X Tracy Cui
Journal:  Biosensors (Basel)       Date:  2015-10-13

10.  Characterization of a Multiple-Scan-Rate Voltammetric Waveform for Real-Time Detection of Met-Enkephalin.

Authors:  S E Calhoun; C J Meunier; C A Lee; G S McCarty; L A Sombers
Journal:  ACS Chem Neurosci       Date:  2019-01-12       Impact factor: 4.418

View more
  3 in total

1.  Modified Sawhorse Waveform for the Voltammetric Detection of Oxytocin.

Authors:  Favian A Liu; Negar Ardabili; Izaiah Brown; Harmain Rafi; Clarice Cook; Rodanthi Nikopoulou; Arianna Lopez; Shouzhong Zou; Matthew R Hartings; Alexander G Zestos
Journal:  J Electrochem Soc       Date:  2022-01-21       Impact factor: 4.316

2.  High resolution voltammetric and field-effect transistor readout of carbon fiber microelectrode biosensors.

Authors:  Whirang Cho; Harmain Rafi; Seulki Cho; Arvind Balijepalli; Alexander G Zestos
Journal:  Sens Diagn       Date:  2022-04-05

3.  Bi-ECDAQ: An electrochemical dual-immuno-biosensor accompanied by a customized bi-potentiostat for clinical detection of SARS-CoV-2 Nucleocapsid proteins.

Authors:  Razieh Salahandish; Fatemeh Haghayegh; Giancarlo Ayala-Charca; Jae Eun Hyun; Mahmood Khalghollah; Azam Zare; Behrouz Far; Byron M Berenger; Yan Dong Niu; Ebrahim Ghafar-Zadeh; Amir Sanati-Nezhad
Journal:  Biosens Bioelectron       Date:  2022-01-25       Impact factor: 10.618

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.