Literature DB >> 3425735

Hemodynamic monitoring for 24 h in unanesthetized rats.

T L Smith1, T G Coleman, K A Stanek, W R Murphy.   

Abstract

A new technique is described that allows minute-to-minute recordings of cardiac output and arterial pressure in unanesthetized rats for periods of 24 h and longer. Rats were instrumented with electromagnetic flow probes and arterial catheters. An electrical and hydraulic swivel was interposed between the rat and recording apparatus to allow free range of movement. Data were collected and analyzed once each minute by computer. Average 24-h values (mean +/- SD) for the following hemodynamic variables were determined in eight rats [expressed where appropriate as a function of body weight (BW)]: cardiac output (98.1 +/- 14.7 ml/min), cardiac index (29.2 +/- 4.4 ml.min-1.100 g BW-1), mean arterial pressure (92.5 +/- 7.8 mmHg), heart rate (347 +/- 45 beats/min), peak aortic flow (403 +/- 32 ml/min), stroke volume (282 +/- 26 microliters), stroke volume index (84.4 +/- 8.1 microliters/100 g BW), and total peripheral resistance index (3.26 +/- 0.46 mmHg.ml-1.min.100 g BW). These results provide a data base of hemodynamic values for unanesthetized adult, Sprague-Dawley male rats, which has not been previously available. In addition, cardiac index, mean arterial pressure, and total peripheral resistance index demonstrated diurnal variation. Diurnal variation contributed substantially to the overall variance observed within these variables. Hourly variance was also substantial and indicates the use of continuous recordings for short-term experiments.

Entities:  

Mesh:

Year:  1987        PMID: 3425735     DOI: 10.1152/ajpheart.1987.253.6.H1335

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  7 in total

1.  Modulation of sympathetic vasoconstriction is critical for the effects of sleep on arterial pressure in mice.

Authors:  Viviana Lo Martire; Alessandro Silvani; Sara Alvente; Stefano Bastianini; Chiara Berteotti; Alice Valli; Giovanna Zoccoli
Journal:  J Physiol       Date:  2018-01-19       Impact factor: 5.182

2.  Dose-response cocaine pharmacokinetics and metabolite profile following intravenous administration and arterial sampling in unanesthetized, freely moving male rats.

Authors:  R M Booze; A F Lehner; D R Wallace; M A Welch; C F Mactutus
Journal:  Neurotoxicol Teratol       Date:  1997 Jan-Feb       Impact factor: 3.763

3.  Noninvasive quantification and optimization of acute cell retention by in vivo positron emission tomography after intramyocardial cardiac-derived stem cell delivery.

Authors:  John Terrovitis; Riikka Lautamäki; Michael Bonios; James Fox; James M Engles; Jianhua Yu; Michelle K Leppo; Martin G Pomper; Richard L Wahl; Jurgen Seidel; Benjamin M Tsui; Frank M Bengel; M Roselle Abraham; Eduardo Marbán
Journal:  J Am Coll Cardiol       Date:  2009-10-20       Impact factor: 24.094

4.  The effects of hyperoxic and hypercarbic gases on tumour blood flow.

Authors:  T J Dunn; R D Braun; W E Rhemus; G L Rosner; T W Secomb; G M Tozer; D J Chaplin; M W Dewhirst
Journal:  Br J Cancer       Date:  1999-04       Impact factor: 7.640

5.  The 24 h pattern of arterial pressure in mice is determined mainly by heart rate-driven variation in cardiac output.

Authors:  Theodore W Kurtz; Heidi L Lujan; Stephen E DiCarlo
Journal:  Physiol Rep       Date:  2014-11-26

6.  Circadian Rhythmicity in Cerebral Microvascular Tone Influences Subarachnoid Hemorrhage-Induced Injury.

Authors:  Darcy Lidington; Hoyee Wan; Danny D Dinh; Chloe Ng; Steffen-Sebastian Bolz
Journal:  Stroke       Date:  2021-12-15       Impact factor: 7.914

Review 7.  Circadian variations of vasoconstriction and blood pressure in physiology and diabetes.

Authors:  Tianfei Hou; Zhenheng Guo; Ming C Gong
Journal:  Curr Opin Pharmacol       Date:  2021-03-12       Impact factor: 5.547

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.