Literature DB >> 34256770

Midterm functional recovery of Total knee arthroplasty patients compared between the ATTUNE knee system and the press fit condylar (PFC) SIGMA knee system.

Ekasame Vanitcharoenkul1, Aasis Unnanuntana2.   

Abstract

BACKGROUND: The ATTUNE Knee System is a new prosthetic design that has theoretical advantages over the Press Fit Condylar (PFC) Sigma Knee System specific to improved knee kinematics and patellofemoral joint tracking. This study aimed to evaluate functional outcomes compared between the ATTUNE and PFC Sigma designs at a minimum follow-up of 5 years.
METHODS: We retrospectively reviewed data from total knee arthroplasty (TKA) patients who received either the ATTUNE or PFC Sigma system during November 2013 to February 2015 at Siriraj Hospital (Bangkok, Thailand). Functional outcomes were evaluated using Timed Up and Go (TUG) test, 2-min walk test (2MWT), modified knee score, numerical rating scale-pain, range of motion (ROM), and rate of anterior knee pain and crepitation at preoperation, 3-months, 1-year, and 5-years postoperatively.
RESULTS: Of 113 patients, 59 and 54 received the PFC Sigma and ATTUNE systems, respectively. At a minimum of 5-years follow-up, all functional outcomes improved significantly from the preoperative period although TUG test and 2MWT declined significantly from 1- to 5-years postoperatively only in the PFC Sigma group. The mean ROM at 5-years postoperatively was significantly higher in ATTUNE than in PFC Sigma; however, the difference was small (116° vs. 110°, respectively; p = 0.041). There were no significant differences in any of the other outcome measurements, including anterior knee pain, clunking, and crepitation, between groups at any study time point.
CONCLUSIONS: ​Our results revealed no major differences in functional outcomes between the PFC Sigma and ATTUNE TKA designs at an intermediate-term follow-up of at least 5 years. Longer-term follow-up study is needed to evaluate the benefits of the ATTUNE design relative to polyethylene wear and the rate of aseptic loosening.
© 2021. The Author(s).

Entities:  

Keywords:  ATTUNE; Functional recovery; PFC; Press fit condylar; TKA; Total knee arthroplasty

Year:  2021        PMID: 34256770     DOI: 10.1186/s12891-021-04464-6

Source DB:  PubMed          Journal:  BMC Musculoskelet Disord        ISSN: 1471-2474            Impact factor:   2.362


  20 in total

1.  Medium-term results with the Press Fit Condylar (PFC) Sigma knee prosthesis the Wrightington experience.

Authors:  Saeed H Zaki; Imran Rafiq; Amit Kapoor; Videsh Raut; Anil K Gambhir; Martyn L Porter
Journal:  Acta Orthop Belg       Date:  2007-02       Impact factor: 0.500

2.  Clinical utility of the 2-minute walk test for older adults living in long-term care.

Authors:  D M Connelly; B K Thomas; S J Cliffe; W M Perry; R E Smith
Journal:  Physiother Can       Date:  2009-05-12       Impact factor: 1.037

3.  Comparative Incidence of Patellofemoral Complications Between 2 Total Knee Arthroplasty Systems in a Multicenter, Prospective Clinical Study.

Authors:  Sean D Toomey; Juan A Daccach; Jinesh C Shah; Sam E Himden; James P Lesko; William G Hamilton
Journal:  J Arthroplasty       Date:  2017-04-20       Impact factor: 4.757

4.  The patella in total knee arthroplasty: to resurface or not is the question.

Authors:  Matthew P Abdel; Sébastien Parratte; Nicolaas C Budhiparama
Journal:  Curr Rev Musculoskelet Med       Date:  2014-06

5.  Bone morphotypes of the varus and valgus knee.

Authors:  E Thienpont; P E Schwab; O Cornu; J Bellemans; J Victor
Journal:  Arch Orthop Trauma Surg       Date:  2017-01-21       Impact factor: 3.067

6.  Total knee replacement in young, active patients. Long-term follow-up and functional outcome.

Authors:  D R Diduch; J N Insall; W N Scott; G R Scuderi; D Font-Rodriguez
Journal:  J Bone Joint Surg Am       Date:  1997-04       Impact factor: 5.284

7.  Patient satisfaction after total knee arthroplasty is affected by their general physical well-being.

Authors:  N D Clement; R Burnett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-05-14       Impact factor: 4.342

8.  The timed up and go test for use on an inpatient orthopaedic rehabilitation ward.

Authors:  Teresa S M Yeung; Jean Wessel; Paul W Stratford; Joy C MacDermid
Journal:  J Orthop Sports Phys Ther       Date:  2008-02-22       Impact factor: 4.751

Review 9.  Anterior knee pain after total knee arthroplasty: a narrative review.

Authors:  Wolf Petersen; Ingo Volker Rembitzki; Gerd-Peter Brüggemann; Andree Ellermann; Raymond Best; Andreas Gösele- Koppenburg; Christian Liebau
Journal:  Int Orthop       Date:  2013-09-22       Impact factor: 3.075

10.  A comparison of clinical- and patient-reported outcomes of the cemented ATTUNE and PFC sigma fixed bearing cruciate sacrificing knee systems in patients who underwent total knee replacement with both prostheses in opposite knees.

Authors:  Brian W Carey; James Harty
Journal:  J Orthop Surg Res       Date:  2018-03-15       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.