Literature DB >> 34253352

Clinical outcomes of osteosynthesis of well-fixed periprosthetic proximal tibial fractures (Felix type 2A) after total knee arthroplasty.

Jae-Ang Sim1, Oog-Jin Shon2, Yong Bum Joo3, Hoon-Sang Sohn4, Seong-Eun Byun5, Ji Wan Kim6.   

Abstract

AIMS: This study aimed to evaluate the clinical and radiologic outcomes of well-fixed periprosthetic tibial fractures after TKA. PATIENTS AND METHODS: The medical records of patients who presented with Felix type 2A periprosthetic tibial fractures after TKA between March 2015 and February 2020 were retrospectively obtained from 5 institutions. Data on injury mechanism, fracture pattern including open fractures and Felix classification, and surgical method were recorded. Functional outcomes including range of motion (ROM) and Knee Society Score (KSS) at postoperative 1 year were reviewed. The need for reoperation was also reviewed. Radiologic findings included union time and mechanical proximal tibial angle (MPTA) at the last radiologic follow-up.
RESULTS: Eighteen patients (13 women, 5 men; average age, 73.9 years) were included. The average follow-up duration was 20.8 months. The fractures resulted from high-energy (11 cases) and low-energy (7 cases) injuries. Two cases involved open fractures. Anatomical locking plates were used in all cases: single plate (4 cases) and dual plates (14 cases). The average number of proximal screws was 7.1 (range, 4-9). All patients achieved bone union at an average of 18.6 weeks without secondary intervention. No infection occurred; however, 1 patient with skin necrosis required local flap. Implant removal was performed in 5 cases: 1 case, skin defect and 4 cases, discomfort due to plate prominence. The average ROM and KSS were 120.3° and 85.9, respectively. The mean MPTA was 87.8°; the MPTA was higher in the single-plate group (94.0° vs. 88.1°, p=0.013). Three cases involved values beyond the normal MPTA range (85-90°): 104° and 96° with a single plate and 92° with dual plates. The malalignment rate was higher in the single-plate group (p=0.043).
CONCLUSION: Felix type 2A periprosthetic tibial fractures treated with minimally invasive osteosynthesis showed excellent clinical outcomes, and tibial alignment was well maintained in the dual-plate group.
Copyright © 2021 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Dual plates; Locking plate; MIPO; Outcomes; Periprosthetic fracture; Tibia; Total knee arthroplasty

Year:  2021        PMID: 34253352     DOI: 10.1016/j.injury.2021.06.022

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  2 in total

1.  Surgical outcomes of subtypes of periprosthetic tibia fractures after total knee arthroplasty.

Authors:  Jiayong Liu; Josh Vander Maten; Julia Beyer; Logan J Roebke; Muhammad Z Moral; Nabil A Ebraheim
Journal:  J Orthop       Date:  2021-12-28

2.  Outcomes of dual plating for unstable distal femoral fractures: a subgroup comparison between periprosthetic and non-periprosthetic fractures.

Authors:  Jae Hyeon Seo; Bum-Sik Lee; Jong-Min Kim; Jung Jae Kim; Ji Wan Kim
Journal:  Int Orthop       Date:  2022-08-15       Impact factor: 3.479

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.