Frontal plane roll-over analysis of prosthetic feet.

Evert S van Hal1, Carolin Curtze2, Klaas Postema3, Juha M Hijmans3, Egbert Otten1.   

Abstract

In prosthetic walking mediolateral balance is compromised due to the lack of active ankle control, by moments of force, in the prosthetic limb. Active control is reduced to the hip strategy, and passive mechanical stability depends on the curvature of the prosthetic foot under load. Mediolateral roll-over curvatures of prosthetic feet are largely unknown. In this study we determined the mediolateral roll-over characteristics of various prosthetic feet and foot-shoe combinations. Characteristics were determined by means of an inverted pendulum-like apparatus. The relationship between the centre of pressure (CoP) and the shank angle was measured and converted to roll-over shape and effective radius of curvature. Further, hysteresis (i.e., lagging in CoP displacement due to material compliance or slip) at vertical shank angle was determined from the hysteresis curve. Passive mechanical stability varied widely, though all measured foot-shoe combinations were relatively compliant. Mediolateral motion of the CoP ranged between 4 mm and 40 mm, thereby remaining well within each foot's physical width. Derived roll-over radii of curvature are also small, with an average of 102 mm. Hysteresis ranges between 20% and 115% of total CoP displacement and becomes more pronounced when adding a shoe. This may be due to slipping of the foot core in its cosmetic cover, or the foot in the shoe. Slip may be disadvantageous for balance control by limiting mediolateral travel of the CoP. It may therefore be clinically relevant to eliminate mediolateral slip in prosthetic foot design.
Copyright © 2021 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Frontal/Coronal plane; Material testing; Mediolateral roll-over; Prosthetic foot curvature

Mesh:

Year:  2021        PMID: 34252823      PMCID: PMC8355200          DOI: 10.1016/j.jbiomech.2021.110610

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.789


  13 in total

1.  Roll-over shapes of human locomotor systems: effects of walking speed.

Authors:  Andrew H Hansen; Dudley S Childress; Erick H Knox
Journal:  Clin Biomech (Bristol, Avon)       Date:  2004-05       Impact factor: 2.063

2.  The equations of motion for a standing human reveal three mechanisms for balance.

Authors:  At L Hof
Journal:  J Biomech       Date:  2006-03-10       Impact factor: 2.712

3.  Comparative roll-over analysis of prosthetic feet.

Authors:  Carolin Curtze; At L Hof; Helco G van Keeken; Jan P K Halbertsma; Klaas Postema; Bert Otten
Journal:  J Biomech       Date:  2009-05-15       Impact factor: 2.712

4.  Effects of interventions on normalizing step width during self-paced dual-belt treadmill walking with virtual reality, a randomised controlled trial.

Authors:  I L B Oude Lansink; L van Kouwenhove; P U Dijkstra; K Postema; J M Hijmans
Journal:  Gait Posture       Date:  2017-07-18       Impact factor: 2.840

5.  Lower-limb amputee recovery response to an imposed error in mediolateral foot placement.

Authors:  Ava D Segal; Glenn K Klute
Journal:  J Biomech       Date:  2014-07-30       Impact factor: 2.712

6.  Staying in dynamic balance on a prosthetic limb: A leg to stand on?

Authors:  Carolin Curtze; At L Hof; Klaas Postema; Bert Otten
Journal:  Med Eng Phys       Date:  2016-04-01       Impact factor: 2.242

7.  The effects of prosthetic foot stiffness on transtibial amputee walking mechanics and balance control during turning.

Authors:  Courtney E Shell; Ava D Segal; Glenn K Klute; Richard R Neptune
Journal:  Clin Biomech (Bristol, Avon)       Date:  2017-08-15       Impact factor: 2.063

8.  Balancing on a narrow ridge: biomechanics and control.

Authors:  E Otten
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-05-29       Impact factor: 6.237

9.  The Narrow Ridge Balance Test: a measure for one-leg lateral balance control.

Authors:  Carolin Curtze; Klaas Postema; Hilda W Akkermans; Bert Otten; At L Hof
Journal:  Gait Posture       Date:  2010-10       Impact factor: 2.840

10.  Height and body-mass index trajectories of school-aged children and adolescents from 1985 to 2019 in 200 countries and territories: a pooled analysis of 2181 population-based studies with 65 million participants.

Authors: 
Journal:  Lancet       Date:  2020-11-07       Impact factor: 202.731

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.