Literature DB >> 34251047

Diagnostic performance of the Elecsys SARS-CoV-2 antigen assay in the clinical routine of a tertiary care hospital: Preliminary results from a single-center evaluation.

Thomas Mueller1, Julia Kompatscher2, Mario La Guardia3.   

Abstract

BACKGROUND: This report describes a manufacturer-independent evaluation of the diagnostic accuracy of the Elecsys SARS-CoV-2 antigen assay from Roche Diagnostics in a tertiary care setting.
METHODS: In this single-center study, we used nasopharyngeal swabs from 403 cases from the emergency department and intensive care unit of our hospital. The reference standard for detecting SARS-CoV-2 was the reverse-transcription polymerase chain reaction (RT-PCR) assay. Cycle threshold (Ct) values were recorded for positive RT-PCR assays. The index test was the Elecsys SARS-CoV-2 antigen assay. This electrochemiluminescence immunoassay produces results as cutoff index (COI) values, with values ≥1.00 being reported as positive.
RESULTS: Of the 403 cases, 47 showed positive results in RT-PCR assays. Of the 47 RT-PCR-positive cases, 12 showed positive results in the antigen assay. Of the 356 RT-PCR-negative cases, all showed negative results in the antigen assay. Thus, the antigen assay showed a sensitivity of 26% (95% CI, 14%-40%) and specificity of 100% (95% CI, 99%-100%). Analysis of the relationship between Ct values and COI values in the 47 RT-PCR-positive cases showed a correlation coefficient of -0.704 (95% CI, -0.824 to -0.522). The true-positive rate of the antigen assay for Ct values of 15-24.9, 25-29.9, 30-34.9, and 35-39.9 was 100%, 44%, 8%, and 6%, respectively.
CONCLUSIONS: The Elecsys SARS-CoV-2 antigen assay has a low sensitivity for detecting SARS-CoV-2 from nasopharyngeal swabs. Hence, we decided to not use this assay in the clinical routine of our hospital.
© 2021 The Authors. Journal of Clinical Laboratory Analysis published by Wiley Periodicals LLC.

Entities:  

Keywords:  Antigen; COVID-19; SARS-CoV-2; diagnostic test; immunoassay; laboratory medicine; polymerase chain reaction; virology

Year:  2021        PMID: 34251047     DOI: 10.1002/jcla.23906

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  2 in total

1.  Severe acute respiratory syndrome coronavirus 2 antibody prevalence in adult patients with short bowel syndrome-A German multicenter cross-sectional study.

Authors:  Elisabeth Blüthner; Ulrich-Frank Pape; Irina Blumenstein; Jeanette Wichmann; Frank Tacke; Simon Moosburner
Journal:  JPEN J Parenter Enteral Nutr       Date:  2022-06-27       Impact factor: 3.896

Review 2.  Performance of Rapid Antigen Tests for COVID-19 Diagnosis: A Systematic Review and Meta-Analysis.

Authors:  Muhammad Fazli Khalid; Kasturi Selvam; Alfeq Jazree Nashru Jeffry; Mohamad Fazrul Salmi; Mohamad Ahmad Najib; Mohd Noor Norhayati; Ismail Aziah
Journal:  Diagnostics (Basel)       Date:  2022-01-04
  2 in total