Literature DB >> 34250911

Comparison between effectiveness of dentine desensitizer and one bottle self-etch adhesive on dentine hypersensitivity.

Muhammad Zohaib Younus1, Muhammad Adeel Ahmed2, Azeem Ul Yaqin Syed3, Jiand Malik Baloch4, Muhammad Ali1, Abubakar Sheikh5.   

Abstract

BACKGROUND: Dentine hypersensitivity is one of the most common chief complaints of patients observed by dentists in their practice. However, there is lack of universal consensus over the selection of reliable treatment modality.
OBJECTIVES: To compare the effectiveness between dentine desensitizer and self-etch adhesive in patients complaining of moderate to severe dentine hypersensitivity pain.
METHODS: A total 254 patients were randomly divided into Group A (Single Bond Universal Agent) and Group B (Seal & Protect Agent) according to the treatment provided. Sensitivity was assessed by means of mechanical (probing) and evaporative (air blast) stimuli. Discomfort Internal Scale (DIS) was explained to patients. DIS scores were recorded after one minute and one month following the application of both agents. Descriptive statistics were calculated. Stratification was done to control confounder and post stratification chi-square test was also applied. RESULT: The statistically significant difference (p= 0.000) in effectiveness between the two groups was observed. The mean discomfort internal scale score at baseline, after 1 minute and after 1 month in Group A was 3.65 ± 0.60, 2.33 ± 0.64 and 0.41 ± 0.71 respectively, while in Group B, it was 3.55 ± 0.58, 2.40 ± 0.62 and 0.72 ± 0.92 respectively. Overall, 86.6% patients observed improvement in dentinal sensitivity in Group A while in Group B only 67.7% patients reported reduction in sensitivity.
CONCLUSION: Self-etch adhesive significantly reduces dentin hypersensitivity, immediately after one minute of its application and is effective for a period of one month when compared to desensitizing agent.

Entities:  

Keywords:  Desensitizing agent; dentine hypersensitivity; self-etch adhesive

Year:  2021        PMID: 34250911     DOI: 10.3233/THC-202636

Source DB:  PubMed          Journal:  Technol Health Care        ISSN: 0928-7329            Impact factor:   1.285


  1 in total

1.  The Retention Effect of Resin-Based Desensitizing Agents on Hypersensitivity-A Randomized Controlled Trial.

Authors:  Manami Tadano; Tomoaki Nakamura; Seira Hoshikawa; Ryoko Hino; Yuriko Maruya; Aya Yamada; Satoshi Fukumoto; Kan Saito
Journal:  Materials (Basel)       Date:  2022-07-26       Impact factor: 3.748

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.