Literature DB >> 34243888

Using a visual analog scale (VAS) to measure tinnitus-related distress and loudness: Investigating correlations using the Mini-TQ results of participants from the TrackYourTinnitus platform.

Albi Dode1, Muntazir Mehdi2, Rüdiger Pryss3, Winfried Schlee4, Thomas Probst5, Manfred Reichert6, Franz Hauck2, Michael Winter6.   

Abstract

INTRODUCTION: Tinnitus, a perception of ringing and buzzing sound in the ear, has not been completely understood yet. It is well known that tinnitus-related distress and loudness can change over time. However, proper comparability for the data collection approaches requires further focused studies. In this context, technology such as the use of mobile devices may be a promising approach. Repeated assessments of tinnitus-related distress and loudness in Ecological Momentary Assessment (EMA) studies require a short assessment, and a Visual Analogic Scale (VAS) is often used in this context. Yet, their comparability with psychometric questionnaires remains unclear and thus was the focus of this study. Research goals: The evaluation of the appropriateness of VAS in measuring tinnitus-related distress and loudness is pursued in this paper.
METHODS: The Mini Tinnitus Questionnaire (Mini-TQ) measured tinnitus-related distress once. Tinnitus-related distress and tinnitus loudness were measured repeatedly using VAS on a daily basis during 7 days in the TrackYourTinnitus (TYT) smartphone app and were summarized per day using mean and median results. Then, correlations between summarized VAS tinnitus-related distress and summarized VAS tinnitus loudness, on the one side, and Mini-TQ, on the other side, were calculated.
RESULTS: Correlations between Mini-TQ and VAS tinnitus-related distress ranged between r = 0.36 and r = 0.52, while correlations between Mini-TQ and VAS tinnitus loudness ranged between r = 0.25 and r = 0.36. The more time difference between the Mini-TQ and the VAS assessments is, the lower the correlations between them. Mean and median VAS values per day resulted in similar correlations.
CONCLUSIONS: Mobile-based VAS seems to be an appropriate approach to utilize daily measurements of tinnitus-related distress.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Correlation; Mini-TQ; TYT; Tinnitus-related distress; VAS

Year:  2021        PMID: 34243888     DOI: 10.1016/bs.pbr.2020.08.008

Source DB:  PubMed          Journal:  Prog Brain Res        ISSN: 0079-6123            Impact factor:   2.453


  2 in total

1.  Effect of intercostal nerve block combined with oxycodone on the postoperative cognitive ability in elderly patients undergoing radical resection of lung cancer.

Authors:  Qiang Wang; Jiao Guo; Minna Hou
Journal:  Am J Transl Res       Date:  2022-09-15       Impact factor: 3.940

2.  Comparison of Different Therapeutic Effects of T-MIST for Chronic Idiopathic Tinnitus.

Authors:  Chaoqun Liang; Qi Fang; Hongjun Chen; Zhixian Wang; Jianming Yang
Journal:  Biomed Res Int       Date:  2022-09-29       Impact factor: 3.246

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.