Literature DB >> 34242694

Improving image quality in transcranial magnetic resonance guided focused ultrasound using a conductive screen.

J R Hadley1, H Odéen2, R Merrill3, S I Adams4, V Rieke5, A Payne6, D L Parker7.   

Abstract

Transcranial Magnetic Resonance guided Focused Ultrasound (TcMRgFUS) has been proven to be an effective treatment for some neurological disorders such as essential and Parkinson's tremor. However, magnetic resonance guidance at 3 Tesla (3T) frequencies and using the large hemispherical transducers required for TcMRgFUS results in artifactual low-signal bands that pass through key regions of the brain. The purpose of this work was to investigate the use of a circular conductive Radio Frequency (RF) screen, that is bent to have a 12 cm radius in one direction and positioned near the top or back of the head, to reduce or remove these artifactual low-signal bands in TcMRgFUS. The impact of using an RF screen to remove these low signal bands was studied in both imaging experiments and electromagnetic simulations. Hydrophone measurements of the acoustic transparency of the bronze 2 mm diameter square mesh screen used in the imaging studies were compared with temperature measurements with and without the screen in heating studies in the TcMRgFUS system. The imaging and simulation studies both show that for the different screen configurations studied in this work, RF screen removes the low-signal bands and increases both homogeneity and signal-to-noise ratio (SNR) throughout the region of the brain. Hydrophone and heating studies indicate that even a 2 mm wire mesh provides minimal attenuation to the ultrasound beam. Simulation results also suggest that a 1 cm mesh will provide adequate artifact suppression with even less ultrasound attenuation. An RF screen that disrupts the natural waveguide nature of the transducer in the 3T MR environment can change the electromagnetic field profile to reduce unwanted artifacts and provide an imaging region which has more homogeneity and higher SNR throughout the brain.
Copyright © 2021 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Conductive radio frequency screen; Low-signal banding artifacts; Transcranial magnetic resonance guided focused ultrasound

Year:  2021        PMID: 34242694     DOI: 10.1016/j.mri.2021.07.002

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  1 in total

1.  Characterization of a Low-Profile, Flexible, and Acoustically Transparent Receive-Only MRI Coil Array for High Sensitivity MR-Guided Focused Ultrasound.

Authors:  Isabelle Saniour; Fraser J L Robb; Victor Taracila; Vishwas Mishra; Jana Vincent; Henning U Voss; Michael G Kaplitt; J Levi Chazen; Simone Angela Winkler
Journal:  IEEE Access       Date:  2022-02-25       Impact factor: 3.476

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.