| Literature DB >> 34237917 |
Yongjun Choi1, Duck-Min Ha2, Sangrak Lee1, Doo-Hwan Kim2.
Abstract
OBJECTIVE: This study was conducted to determine reduction of various odorous materials from a swine farm equipped with a continuous pit recirculation system (CPRS) with aerobically treated liquid manure.Entities:
Keywords: Aerobic Digestion; Continuous Pit Recirculation System; Liquid Fertilizer; Odorous Material; Swine Facility
Year: 2021 PMID: 34237917 PMCID: PMC8738943 DOI: 10.5713/ab.21.0135
Source DB: PubMed Journal: Anim Biosci ISSN: 2765-0189
Condition of experimental swine house
| Farm[ | Total number of pigs | Housing type | Ventilation | Number of pigs in the barn | Housing size (m) | Fermenter size (m) | Storage tank (m) | Catchment tank (m) |
|---|---|---|---|---|---|---|---|---|
| A | 4,000 | Confined | Forced | 600 | 50×12×2.7 | 18×8×2 | 42×13×2 | - |
| Confined | Forced | 600 | 50×12×2.7 | 18×8×2 | 42×13×2 | - | ||
| B | 3,000 | Confined | Forced | 600 | 35×18×4 | 21×8×3 | 7×7×4.5 | 30×7×3 |
| C | 2,000 | Confined | Forced | 400 | 22×13×3 | 24×9×3 | 25×2×3 | 12×7×3 |
A, a common farm not equipped with continuous pit recirculation system; B and C, farms operating continuous pit recirculation systems (Figure 1).
Figure 1Pictures of experimental farms. (a) a common farm not equipped with continuous pit recirculation system (Farm A, control); (b) Farm B; and (c) Farm C. (d) and (e) two rooms of a finishing pig confinement building in a farm not equipped with continuous pit recirculation system; (f) and (g) two room of a finishing pig confinement building in the farm equipped with continuous pit recirculation system; (h) and (i) air-treated liquid manure manufacturing facility.
Figure 2Concrete pit of the pig barn. (a) Slurry pit; (b) Stank.
Figure 3Dimensions of the thermal mesophilic aerobic digestion facility.
Figure 4Schematic diagram of the experimental farm facilities with a continuous pit recirculation system and the auto thermal mesophilic aerobic digestion facility. (a) pit mixing; (b) slurry outlet; (e) slurry tank; (f) flow control tank; (g) inlet tank; (h) first aeration tank; (i) anoxic (first and second); (j) second aeration tank; (k) third aeration tank; (l) first settling tank; (m) second settling tank; (n) circulation tank.
Figure 5Schematic diagram of the experimental farm facilities with a continuous pit recirculation system (a) 40 to 60 cm; (b) 20 to 40 cm; (c) under 0 to 20 cm; (d) indoor gas sampling point; (e) exhaust fan sampling point.
Comparison of chemical properties of slurry pit manure according to the application of a continuous pit recirculation system in the finishing pig house
| Items | Control | CPRS | SEM | p-value |
|---|---|---|---|---|
| EC (dS/m) | 24.1 | 12.6 | 3.32 | <0.001 |
| pH | 7.7 | 7.9 | 0.07 | 0.011 |
| BOD (mg/L) | 14,157.0 | 1,563.4 | 1,237.4 | <0.001 |
| COD (mg/L) | 18,541.0 | 3,319.8 | 2,143.7 | <0.001 |
| SS (mg/L) | 35,063.0 | 3,425.6 | 5,261.2 | 0.001 |
| T-N (mg/L) | 5,786.5 | 1,153.7 | 575.5 | <0.001 |
| T-P (mg/L) | 1,444.3 | 150.4 | 346.3 | 0.006 |
| NH4-N (mg/L) | 2,003.3 | 606.5 | 72.8 | <0.001 |
| TOC (g/L) | 12,214.0 | 2,440.5 | 1,077.6 | <0.001 |
| TC (g/L) | 14,626.0 | 3,679.7 | 981.5 | <0.001 |
CPRS, continuous pit recirculation system; SEM, standard error of the mean; EC, electrical conductivity; BOD, biochemical oxygen demand; COD, chemical oxygen demand; SS, suspended solids; T-N, total nitrogen; T-P, total phosphate; TOC, total organic carbon; TC, total carbon.
Chemical properties of the recirculation liquid based on the treatment process equipped within the continuous pit recirculation system
| Chemical properties | Storage tank | Slurry pit | Outlet of slurry pit | Anoxic tank | SEM | p-value |
|---|---|---|---|---|---|---|
| EC (dS/m) | 11.9 | 12.5 | 13.5 | 11.7 | 0.91 | 0.448 |
| pH | 7.8 | 7.9 | 7.8 | 7.9 | 0.05 | 0.057 |
| BOD (mg/L) | 1,379.9[ | 1,620.3[ | 1,344.2[ | 1,197.7[ | 97.69 | 0.032 |
| COD (mg/L) | 2,985.8 | 3,301.9 | 3,177.4 | 3,017.9 | 254.54 | 0.770 |
| SS (mg/L) | 2,407.9 | 3,377.8 | 2,652.9 | 2,478.3 | 295.09 | 0.095 |
| T-N (mg/L) | 1,008.5[ | 1,171.5[ | 1,134.4[ | 1,054.2[ | 47.05 | 0.008 |
| T-P (mg/L) | 106.1[ | 150.3[ | 109.6[ | 84.8[ | 10.58 | 0.001 |
| NH4-N (mg/L) | 429.2[ | 626.2[ | 577.4[ | 471.4[ | 33.55 | 0.000 |
| TOC (g/L) | 1,668.2 | 2,479.9 | 2,171.4 | 1,802.4 | 392.93 | 0.355 |
| TC (g/L) | 2,931.4 | 3,733.9 | 3,735.8 | 3,240.6 | 337.77 | 0.117 |
SEM, standard error of the means; EC, electrical conductivity; BOD, biochemical oxygen demand; COD, chemical oxygen demand; SS, suspended solids; T-N, total nitrogen; T-P, total phosphate; TOC, total organic carbon; TC, total carbon.
Means in the same row with different superscripts differ significantly p<0.05.
Comparison of odor intensity and atmosphere characteristics in the finishing pig house according to the application of continuous pit recirculation system
| Items | Control | CPRS | SEM | p-value |
|---|---|---|---|---|
| Odor intensity[ | ||||
| Indoor | 3.49 | 2.22 | 0.13 | 0.001 |
| Exhaust | 3.48 | 2.04 | 0.14 | 0.001 |
| Outside | 2.2 | 1.07 | 0.14 | 0.001 |
| Indoor atmosphere | ||||
| Temperature (°C) | 31.19 | 27.13 | 1.65 | 0.008 |
| Humidity (%) | 58.99 | 61.03 | 8.22 | 0.805 |
| Wind velocity (m/s) | 0.13 | 0.15 | 0.12 | 0.853 |
| CO2 (ppm) | 1,514.72 | 605.64 | 141.65 | 0.001 |
| NH3 (ppm) | 19.00 | 6.83 | 1.62 | 0.001 |
| H2S (ppm) | 0.54 | 0.11 | 0.14 | 0.008 |
CPRS, continuous pit recirculation system; SEM, standard error of the means.
Odor intensity was scored according to a 6-ladder whole number scale using the air dilution sensory method of the standard methods for the examination of odor [9] (0, undetectable; 1, barely detectable; 2, moderate; 3, strong; 4, very strong; 5, unbearable). Indoor, inner sampling point of finishing pig house (Figure 5); exhaust, exhaust fan sampling point of finishing pig house (Figure 5); outside, farm site boundary sampling point.
Comparison of odorous material contents at various sampling points according to the application of continuous pit recirculation system
| Odorous materials | Control[ | CPRS | SEM | p-value[ | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
|
|
| ||||||||
| Indoor | Exhaust | Outside | Indoor | Exhaust | Outside | S | L | S×L | ||
| NH3 (ppm) | 19.98 | 17.73 | 4.23 | 6.38 | 6.73 | 0.51 | 1.18 | 0.000 | 0.000 | 0.001 |
| H2S (ppm) | 3.55 | 2.58 | 0.68 | 0.93 | 0.73 | 0.00 | 0.38 | 0.000 | 0.000 | 0.025 |
| MM (ppb) | 16.70 | 11.63 | 0.93 | 0.13 | 0.03 | 0.00 | 2.80 | 0.000 | 0.023 | 0.025 |
| DMD (ppb) | 0.88 | 0.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.07 | 0.000 | 0.000 | 0.000 |
| TMA (ppb) | 0.04 | 0.03 | 0.00 | 0.01 | 0.01 | 0.00 | 0.00 | 0.000 | 0.000 | 0.000 |
| Phenol (ppb) | 9.85 | 6.58 | 0.40 | 4.92 | 3.16 | 0.00 | 1.07 | 0.000 | 0.000 | 0.030 |
| Indole (ppb) | 5.38 | 5.35 | 0.35 | 2.45 | 1.78 | 0.00 | 0.42 | 0.000 | 0.000 | 0.000 |
| Skatole (ppb) | 7.38 | 3.83 | 0.45 | 2.51 | 0.78 | 0.00 | 0.54 | 0.000 | 0.000 | 0.001 |
CPRS, continuous pit recirculation system; SEM, standard error of the mean; MM, methyl mercaptan; DMD, dimethyl disulfide; TMA, trimethylamine.
Indoor, inner sampling point of finishing pig house (Figure 5, [d]); exhaust, exhaust fan sampling point of finishing pig house (Figure 5, [e]); outside, Farm site boundary sampling point.
S, the effect of recirculation system; L, the effect of analysis location; S×L, Interaction between recirculation and analysis location effect.