Literature DB >> 34236462

Computed tomography imaging using split-bolus contrast injection with volume scan of aortic root and heart for preoperative evaluation of transcatheter aortic valve implantation.

Hitomi Koyanagi1, Yoshinori Tsutsumi2, Yoshiyuki Tokuda3, Akihito Tanaka4, Maki Endo2, Yasushi Furukawa2, Shinji Abe2.   

Abstract

The purpose of this study was to investigate using split-bolus contrast injection (SPBI) with volume scanning of the heart and aortic root with helical scanning of the access route, compared to single bolus contrast injection (SI) with variable helical pitch scanning (VHP) of the heart and aortic root and access route in a preoperative evaluation before transcatheter aortic valve implantation (TAVI). Thirty-five patients who underwent preoperative CT before TAVI using SPBI (contrast media: 24.5 mgI /kg/s, injected for 12 s for heart scan and then injected for 8 s for access route) were examined. Electrocardiogram (ECG) gated scans of the heart were performed by volume scan, after a period of time, non-gated helical scans of the aorto-iliac were performed (SPBI method). For comparison, 40 patients who had a single bolus injection (26.5 mg I/kg/s, injected for period of the scan time plus 3 s) and a VHP scan (SI method) before the SPBI method was performed were included in the study. The image qualities of the coronary arteries, aortic root, and access route (aorta-iliac), as well as radiation and iodine doses, were assessed. In visual assessment, image quality of coronary artery was significantly better with the SPBI method (grade; excellent: 57.1% in SPBI vs. 24.3% in SI, p = 0.03). There was no significant difference in image quality of the aortic root by visual assessment. The signal-to-noise (SNR) and contrast-to-noise ratio (CNR) of coronary and aortic root were not significantly different between the two methods. The access route showed significantly higher SNR (45.7 ± 11.5 vs. 34.3 ± 9.8, p < 0.001) and CNR (36.0 ± 9.7 vs. 28.0 ± 8.8, p < 0.001) for the SPBI method. The SPBI method compared to SI method reduced iodine dose by 10% and radiation dose by 45%. Preoperative CT imaging before TAVI using SPBI with volume scan is useful and can reduce iodine and radiation doses.
© 2021. Springer Japan KK, part of Springer Nature.

Entities:  

Keywords:  Aortic root; Area detector CT; Coronary arteries; Split-bolus injection; Transcatheter aortic valve implantation; Volume scan

Mesh:

Substances:

Year:  2021        PMID: 34236462     DOI: 10.1007/s00380-021-01899-8

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  1 in total

1.  Aortic arch plaque morphology in patients with coronary artery disease undergoing coronary computed tomography angiography with wide-volume scan.

Authors:  Kenichiro Otsuka; Hirotoshi Ishikawa; Yasushi Kono; Shinya Oku; Hiroki Yamaura; Kuniyuki Shirasawa; Kumiko Hirata; Kenei Shimada; Noriaki Kasayuki; Daiju Fukuda
Journal:  Coron Artery Dis       Date:  2022-07-22       Impact factor: 1.717