| Literature DB >> 34236449 |
Imke Schmerwitz1, Philipp Jungebluth2, Stephan Bartels2, Thomas Hockertz2.
Abstract
OBJECTIVE OF SURGERY: High primary stability of the pelvic girdle with full weight bearing. INDICATIONS: Instability and immobility in patients with osteoporotic fractures of the pelvis. CONTRAINDICATIONS: Decubitus ulcers, infections. SURGICAL TECHNIQUE: Minimally invasive posterior locked compression plate 4.5 LCP (locked compression plate, DePuy Synthes, Zuchwil, Switzerland). FOLLOW-UP: Immediate mobilization with full weight bearing, X‑ ray control. EVIDENCE: The follow-up examination of a collective of 34 patients showed no implant loosening and a relatively low radiation exposure.Entities:
Keywords: Angular stable pelvic plate; Fragility fractures of the pelvis; Insufficiency fractures; Osteoporotic pelvis fractures
Mesh:
Year: 2021 PMID: 34236449 PMCID: PMC8386502 DOI: 10.1007/s00113-021-01039-x
Source DB: PubMed Journal: Unfallchirurg ISSN: 0177-5537 Impact factor: 1.000