Literature DB >> 34230546

Proposal of accurate cup placement procedure during total hip arthroplasty based on pelvic tilt discrepancies in the lateral position.

Manabu Tsukamoto1, Makoto Kawasaki2, Hitoshi Suzuki1, Teruaki Fujitani1, Akinori Sakai1.   

Abstract

By combining the anatomical-pelvic-plane (APP) positioner with a newly improved navigation system during total hip arthroplasty (THA), it is theoretically possible to determine cup orientation based on the APP while tracking pelvic movement. The purpose of this study was to determine the navigation accuracy and whether the error is related to the pelvic position fixed by the positioner. Fifty hips that underwent primary THA between 2018 and 2020 were analysed. The accuracy was 2.34° at radiographic inclination (RI) and - 5.01° at radiographic anteversion (RA), and the error was within 10° at both RI and RA in only 40 of 50 hips (80.0%). The discrepancy in pelvic sagittal tilt was correlated with the cup orientation error and especially strongly correlated with the RA error (r = - 0.751, p < 0.001). When RI and RA were calculated using a correction formula to determine the true cup orientation based on the pelvic tilt discrepancies, the error in both RI and RA was within 10° in all cases (100%). The navigation accuracy is related to the pelvic position fixed by the positioner, and the correction formula for the target angle that considers pelvic tilt discrepancies can lead to accurate cup placement in the future.

Entities:  

Year:  2021        PMID: 34230546     DOI: 10.1038/s41598-021-93418-y

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  3 in total

1.  Does accelerometer-based portable navigation provide more accurate and precise cup orientation without prosthetic impingement than conventional total hip arthroplasty? A randomized controlled study.

Authors:  Masato Kiyohara; Satoshi Hamai; Kyohei Shiomoto; Satoru Harada; Tetsunari Harada; Goro Motomura; Satoshi Ikemura; Masanori Fujii; Shinya Kawahara; Yasuharu Nakashima
Journal:  Int J Comput Assist Radiol Surg       Date:  2022-03-26       Impact factor: 2.924

2.  Logistic Regression Analysis of Risk Factors and Improvement of Clinical Treatment of Traumatic Arthritis after Total Hip Arthroplasty (THA) in the Treatment of Acetabular Fractures.

Authors:  Zijun Zhao; Long Feng
Journal:  Comput Math Methods Med       Date:  2022-05-04       Impact factor: 2.809

3.  Accuracy of a novel accelerometer-based navigation (Naviswiss) for total hip arthroplasty in the supine position.

Authors:  Masahiro Hasegawa; Yohei Naito; Shine Tone; Akihiro Sudo
Journal:  BMC Musculoskelet Disord       Date:  2022-06-04       Impact factor: 2.562

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.