Literature DB >> 34229098

Dual Stenting with New-Generation Stents for Aneurysm Embolization in Acute Subarachnoid Hemorrhage.

Bige Sayin1, Ayberk Karaman2, Sinan Balci3, İlkay Akmangit1, Ergun Daglioglu2, Anil Arat4.   

Abstract

OBJECTIVE: Endosaccular treatment is the backbone of endovascular treatment for acutely ruptured aneurysms. Stent-assisted coiling is a niche technique in this context. Data on X-stenting or Y-stenting (dual crossing stenting, DCS) in the acute phase after subarachnoid hemorrhage (aSAH) are scarce, and the impact of stent properties on the outcome is unknown. We retrospectively evaluated the clinical and imaging results of DCS in patients treated for aSAH.
METHODS: Patients with aSAH treated with DCS were evaluated retrospectively. Patient and procedural characteristics were evaluated to determine clinical outcomes, associated complications, and follow-up imaging findings.
RESULTS: Sixteen procedures (16 patients; 10 women, mean age 55.8) were performed within 3.2 ± 2.6 days (range 1-10 days) of aSAH. Only the latest generation of intracranial stents (dual Neuroform Atlas-12 cases, dual Leo Baby-2 cases, Neuroform Atlas with Acclino Flex, or Leo Baby-2 cases) were used. Technical success rate was 100%; however, 25% of the procedures were complicated, leading to adverse events in 3 procedures (18.8%; 2 stent thrombosis, 1aneurysm rupture). Procedure-related morbidity and mortality and overall permanent morbidity and mortality were 6.3%, none, 6.3%, and 12.5%, respectively. No additional neurologic events were noted on a mean clinical follow-up of 160 ± 156 (range: 1-540) days.
CONCLUSIONS: Our findings and the patient-by-patient data we extracted from the literature suggest that DCS can be performed with new-generation, low-profile stents in aSAH if a definite procedural risk is acceptable for a specific patient. New-generation open-cell stent combinations appear as a viable choice for DCS in aSAH.
Copyright © 2021 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Aneurysmal; Dual stent; Embolization; X stent; Y stent

Mesh:

Year:  2021        PMID: 34229098     DOI: 10.1016/j.wneu.2021.06.135

Source DB:  PubMed          Journal:  World Neurosurg        ISSN: 1878-8750            Impact factor:   2.104


  1 in total

1.  Effect of the Shelving Technique on the Outcome of Embolization in Intracranial Bifurcation Aneurysms.

Authors:  F Çay; A Arat
Journal:  AJNR Am J Neuroradiol       Date:  2022-07-28       Impact factor: 4.966

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.