Literature DB >> 3422779

Effects of sterilization on the mechanical properties and the surface topography of nickel-titanium arch wires.

M J Mayhew1, R P Kusy.   

Abstract

The effects of sterilization on the mechanical properties and the surface topography were determined on 0.017 x 0.025-inch Nitinol and Titanal arch wires. Three approved heat sterilization methods were used: dry heat, formaldehyde-alcohol vapor, and steam autoclave. Elastic moduli were obtained on 1-inch segments in 3-point bending. Laser scans of flatwise wire surfaces were conducted to detect surface alterations--whether they were caused by tarnish, corrosion, or pitting. Tensile properties were determined on 7-inch lengths: the 0.1% yield strength, the ultimate tensile strength, and the percent elongation at break. Within the confines of the present sterilization experiments, no detrimental changes were observed for either the selected mechanical properties or the surface topography. When the mean values of the two products were compared, Nitinol was less compliant but stronger than Titanal. Laser spectroscopy showed that Titanal possessed at least three times more specular reflectivity than Nitinol.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3422779     DOI: 10.1016/s0889-5406(88)80008-8

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  6 in total

1.  Evaluation of Mechanical and Physical Properties of Clinically Used and Recycled Superelastic NiTi Wires.

Authors:  Venkata Naidu Bavikati; Gowri Sankar Singaraju; Prasad Mandava; Sai Sandeep Killamsetty; Venkatesh Nettam; Praveen Kumar Reddy Karnati
Journal:  J Clin Diagn Res       Date:  2016-07-01

2.  Effects of repeated sterilization cycles on primary stability of orthodontic mini-screws.

Authors:  Sercan Akyalcin; Holly P McIver; Jeryl D English; Joe C Ontiveros; Ron L Gallerano
Journal:  Angle Orthod       Date:  2012-12-17       Impact factor: 2.079

3.  Effect of immersion in hydrochloric acid and sodium hypochlorite and autoclave sterilization on the force characteristics of orthodontic nickel-titanium open coils.

Authors:  Saeed Noorollahian; Mehrnaz Zakizade
Journal:  Dent Res J (Isfahan)       Date:  2021-02-23

4.  Impact of recycling on the mechanical properties of nickel-titanium alloy wires and the efficacy of their reuse after cold sterilization.

Authors:  Ankit Yadav; Poonam K Jayaprakash; Rajeshwar Singh; Meeta Dawer; Palash Modi; Bhumika Sehdev; Kiran K Ganji
Journal:  J Orthod Sci       Date:  2020-08-18

5.  Effect of dry heat and steam sterilization on load-deflection characteristics of β-titanium wires: An in vitro study.

Authors:  Shiva Alavi; Neda Sinaee
Journal:  Dent Res J (Isfahan)       Date:  2012-09

6.  Evaluation of tensile strength and surface topography of orthodontic wires after infection control procedures: An in vitro study.

Authors:  M Brindha; N Kurunji Kumaran; K Rajasigamani
Journal:  J Pharm Bioallied Sci       Date:  2014-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.