| Literature DB >> 34219497 |
Hellen Fontão Alexandre1,2, Katerine Cristhine Cani1,3, Juliana Araújo1,4, Anamaria Fleig Mayer1,2,4.
Abstract
The study objective was to investigated the reliability and validity of the ADL-Glittre test (TGlittre) to assess the functional status of patients with interstitial lung disease (ILD). Twenty-one individuals with ILD participated (age: 63 ± 11 years; DLCO: 51.0 ± 12.6%predicted), evaluated with body plethysmography, Saint George Respiratory Questionnaire, modified Medical Research Council dyspnea scale, six-minute walk test (6MWT) and monitoring of physical activity of daily living. Two TGlittre were performed, with an interval of 30 minutes between them. The TGlittre demonstrated high test-retest reliability, with an intraclass correlation coefficient of 0.90 (95%CI: 0.75-0.96; p < 0.001). Nineteen patients (90.5%) performed better on the second test (mean difference between TGlittre 1 and 2: -0.57 ± 0.96 minute; p = 0.001), with a learning effect of 11.6%. The time in TGlittre correlated with 6MWT (r = -0.70; p = 0.002) and with the total energy expenditure in physical activity of daily living (r = -0.52; p = 0.02). In %predicted, TGlittre and 6MWT also correlated (r = -0.50; p = 0.04). Correlations were observed between TGlittre and pulmonary function variables (r = -0.47 to -0.57; p = 0.01 to p = 0.04). There was no difference in the physiological response between TGlittre 1 and 2, and between TGlittre and 6MWT (p > 0.05). In conclusion, the TGlittre is reliable and valid for assessing functional status of patients with ILD.Entities:
Keywords: Lung diseases; activities of daily living; exercise test; health care; interstitial; outcome assessment; physical functional performance; reproducibility of results
Year: 2021 PMID: 34219497 PMCID: PMC8261846 DOI: 10.1177/14799731211012962
Source DB: PubMed Journal: Chron Respir Dis ISSN: 1479-9723 Impact factor: 2.444
Figure 1.TGlittre’s ADL circuit (Source: author’s own files).
Characterization data of the sample of 21 individuals with ILD.
| Variables | Mean ± SD | |
|---|---|---|
| Age (years) | 63.2 ± 11.4 | |
| BMI (kg/m2) | 27.5 ± 5.30 | |
| Absolute | %predicted | |
| Lung Function | ||
| FEV1 (L) and (%pred) | 2.12 ± 0.66 | 78.0 ± 20.8 |
| FVC (L) and (%pred) | 2.56 ± 0.87 | 74.7 ± 21.2 |
| VC (L) and (%pred) | 2.62 ± 0.87 | 78.9 ± 23.2 |
| TLC (L) and (%pred) | 3.98 ± 1.07 | 73.2 ± 16.8 |
| DLCO (mmol/min*kPa) and (%pred) | 4.42 ± 1.33 | 51.0 ± 12.6 |
| 6MWT (m) and (%pred) | 437 ± 89.8 | 79.5 ± 14.6 |
| Mean ± SD | ||
| mMRC | 1 [1]* | |
| SGRQ | ||
| Total | 43.5 ± 17.7 | |
| Symptoms | 44.5 ± 18.6 | |
| Activity | 57.5 ± 18.6 | |
| Impact | 37.0 ± 19.9 | |
| PADL | ||
| Time in moderate and vigorous activities (min) | 84.7 ± 33.3 | |
| Time in sedentary behavior (min) | 536 ± 70.6 | |
| Steps (number/day) | 5292 ± 1993 | |
| Walking movement intensity (m/s2) | 1.90 ± 0.43 | |
| Energy expenditure walking (Kcal) | 320 ± 138 | |
| Total energy expenditure (Kcal) | 1310 ± 300 | |
SD: standard deviation; BMI: body mass index; kg: kilogram; m: meters; %predicted: percentage of predicted; FEV1: forced expiratory volume in 1 second; L: liters; %pred: % of predicted; FVC: forced vital capacity; VC: vital capacity; TLC: total lung capacity; DLCO: carbon monoxide diffusing capacity; mmol: millimoles; min: minutes; kPa: kilopascals; 6MWT: 6-minute walk test; mMRC: modified Medical Research Council scale; SGRQ: Saint George Respiratory Questionnaire; PADL: physical activity of daily living; s: seconds; Kcal: kilocalories.
* Results presented in median [interquartile range].
Figure 2.Bland-Altman distribution graph for the two TGlittre performed by individuals with ILD. Mean = −0.6 min; +2 SD = 1.4 min; and −2 SD = −2.5 min.
Comparison between total times and laps times spent on TGlittre 1 and TGlittre 2.
| TGlittre 1 (Mean ± SD) | TGlittre 2 (Mean ± SD) | Δ TGlittre (Mean ± SD) | p | |
|---|---|---|---|---|
| Total time (min) | 4.93 ± 1.70 | 4.36 ± 1.44 | −0.57 ± 0.96 | 0.001* |
| Time (%pred) | 161 ± 51.0 | 143 ± 46.6 | −18.0 ± 29.8 | 0.001* |
| Lap 1 (s) | 55.1 ± 14.4 | 47.0 ± 10.5 | −8.14 ± 6.19 | <0.001* |
| Lap 2 (s) | 52.5 ± 14.5 | 46.3 ± 8.83 | −6.14 ± 6.91 | <0.001* |
| Lap 3 (s) | 71.8 ± 79.0 | 55.1 ± 33.2 | −16.0 ± 81.2 | 0.03* |
| Lap 4 (s) | 57.1 ± 22.3 | 57.6 ± 24.0 | 1.21 ± 14.4 | 0.17 |
| Lap 5 (s) | 55.0 ± 15.3 | 55.9 ± 26.0 | 1.48 ± 20.9 | 0.05 |
TGlittre: Glittre-ADL Test; SD: standard deviation; Δ: TGlittre2 − TGlittre1; p: significance level; min: minutes; %pred: percentage of predicted; s: seconds.
*Statistic difference (p < 0.05).
Figure 3.Correlations between time spent on TGlittre (minutes) and distance on 6MWT, in meters (a); performance on TGlittre (%predicted) and distance on 6MWT, in percentage of predicted (b); and between time spent on TGlittre (minutes) and total energy expenditure, in kilocalories (c).