Lucas Mansano Sarquis1, Wilson Michaelis2, Antonio Lacerda Santos2, Cristiano Silva Pinto1, Rogerio Akira Yokoyama2, Erick Fernando Seguro1, Antonio Luiz da Costa Martins2, Vinicius Belas do Vale3.
Abstract
BACKGROUND: Aortic injuries caused by blunt chest traumas have high pre-hospital and emergency mortality. The endovascular approach is one option for treatment of these injuries, but many outcomes related to this approach remain unknown.Entities:
Keywords: aortic diseases; endovascular procedures; thoracic aorta; wounds
Year: 2020 PMID: 34211523 PMCID: PMC8218017 DOI: 10.1590/1677-5449.200074
Source DB: PubMed Journal: J Vasc Bras ISSN: 1677-5449
Epidemiological characteristics of the patients.
|
| |
|---|---|
| Gender | |
| Male | 14 (87.5%) |
| Female | 2 (12.5%) |
| Age (mean) | 37 years |
| Mechanism of trauma | |
| Collision | 12 (75%) |
| Run over | 3 (18.7%) |
| Vehicle rolled over | 1 (6.3%) |
Figure 1Graph of most common concurrent injuries.
Figure 2Graph showing distribution of cases by grade of injury.
Figure 3Diagnostic angiotomography of Grade I aortic injury – case 3.
Figure 4Diagnostic angiotomography of Grade II aortic injury – case 9.
Figure 5Diagnostic angiotomography of Grade III aortic injury – case 10.
Figure 6Diagnostic angiotomography of Grade IV aortic injury –case 6.
Figure 7Control angiotomography 30 days after endovascular treatment – case 2.
Figure 8Control angiotomography 6 months after endovascular treatment – case 5.
Description of cases by grade of injury, dimensions of the aorta, material utilized, oversizing, interval elapsed between trauma and treatment, and surgical complications.
|
|
|
|
|
|
|
| |
|---|---|---|---|---|---|---|---|
| Case 1 | III | 21 | 16 | Endurant® (Medtronic, Minneapolis, United States), 24 × 82 mm | 14% | 24 | None |
| Case 2 | II | 26 | 23 | Valiant Captivia® (Medtronic), 30 × 150 mm | 15% | 288 | None |
| Case 3 | I | 23 | 23 | Valiant Captivia® (Medtronic), 26 × 86 mm | 13% | 24 | None |
| Case 4 | II | 30 | 30 | Valiant Captivia® (Medtronic), 34 × 12 cm, + fenestration for left subclavian artery: Advanta-V12® stent (Getinge AB, Getinge, Sweden), 10 × 38 cm | 13% | 60 | Dissection progressed |
| Case 5 | III | 24 | 18 | Valiant Captivia® (Medtronic), 28 × 157 mm | 16% | 36 | None |
| Case 6 | IV | 20 | 19 | Endurant II® (Medtronic), 24 × 82 mm (extension branch) | 20% | 36 | None |
| Case 7 | II | 22 | 20 | Apolo Thoracic stent graft (NANO®, Santa Catarina, Brazil), 25 × 120 mm | 13% | 72 | None |
| Case 8 | II | 20 | 18 | Valiant Captivia® (Medtronic), 24 × 150 mm | 14% | 34 | Death – unrelated to aortic trauma |
| Case 9 | II | 24 | 21 | Endurant II® (Medtronic), 28 × 82 mm | 16% | 6 | None |
| Case 10 | III | 23 | 20 | Valiant Captivia® (Medtronic), 28 × 157 mm | 21% | 144 | None |
| Case 11 | II | 22 | 18 | Valiant Thoracic® (Medtronic) with manual fenestration, 26 × 164 mm | 18% | 72 | Late type II endoleak |
| Case 12 | II | 22 | 20 | Gore Tag® (L. Gore & Associates, Inc., Delaware, United States), 26 × 100 mm | 18% | 24 | None |
| Case 13 | III | 19 | 16 | Valiant Captivia® (Medtronic), 22 × 100 mm | 15% | 12 | None |
| Case 14 | II | 22 | 19 | Endurant II® (Medtronic), 26 × 130 mm | 18% | 48 | None |
| Case 15 | III | 28 | 24 | Cook Zenith® (Cook Group Inc., Indiana, United States), 34 × 34 × 159 mm | 21% | 72 | None |
| Case 16 | III | 28 | 23 | Valiant® (Medtronic) 34 × 34 × 150 mm | 21% | 192 | Death - unrelated to aortic trauma |
Características epidemiológicas dos pacientes.
|
| |
|---|---|
| Gênero | |
| Masculino | 14 (87,5%) |
| Feminino | 2 (12,5%) |
| Idade (média) | 37 anos |
| Mecanismo de trauma | |
| Colisão | 12 (75%) |
| Atropelamento | 3 (18,7%) |
| Capotamento | 1 (6,3%) |
Figura 1Gráfico com as principais lesões associadas.
Figura 2Gráfico com a divisão dos casos de acordo com o grau da lesão.
Figura 3Angiotomografia diagnóstica com lesão de aorta Grau 1 – caso 3.
Figura 4Angiotomografia diagnóstica com lesão de aorta Grau 2 – caso 9.
Figura 5Angiotomografia diagnóstica com lesão de aorta Grau 3 – caso 10.
Figura 6Angiotomografia diagnóstica com lesão de aorta Grau 4 – caso 6.
Figura 7Angiotomografia de controle em 30 dias após o tratamento endovascular – caso 2.
Figura 8Angiotomografia de controle em 6 meses após o tratamento endovascular – caso 5.
Descrição dos casos de acordo com o grau, dimensões da aorta, material utilizado, oversizing, intervalo entre trauma e tratamento e as complicações cirúrgicas.
|
|
|
|
|
|
|
| |
|---|---|---|---|---|---|---|---|
| Caso 1 | III | 21 | 16 | Endurant® (Medtronic, Minneapolis, EUA) 24 × 82 mm | 14% | 24 | Ausentes |
| Caso 2 | II | 26 | 23 | Valiant Captivia® (Medtronic) 30 × 150 mm | 15% | 288 | Ausentes |
| Caso 3 | I | 23 | 23 | Valiant Captivia® (Medtronic) 26 × 86 mm | 13% | 24 | Ausentes |
| Caso 4 | II | 30 | 30 | Valiant Captivia® (Medtronic) 34 × 12 cm + fenestração da artéria subclávia esquerda: stent Advanta-V12® (Getinge AB, Getinge, Suécia) 10 × 38 cm | 13% | 60 | Progressão da dissecção |
| Caso 5 | III | 24 | 18 | Valiant Captivia® (Medtronic) 28 × 157 mm | 16% | 36 | Ausentes |
| Caso 6 | IV | 20 | 19 | Endurant II® (Medtronic) 24 × 82 mm (ramo extensor) | 20% | 36 | Ausentes |
| Caso 7 | II | 22 | 20 | Apolo Reta Torácica (NANO®, Santa Catarina, Brasil) 25 × 120 mm | 13% | 72 | Ausentes |
| Caso 8 | II | 20 | 18 | Valiant Captivia® (Medtronic) 24 × 150 mm | 14% | 34 | Óbito - não relacionado ao trauma de aorta |
| Caso 9 | II | 24 | 21 | Endurant II® (Medtronic) 28 × 82 mm | 16% | 6 | Ausentes |
| Caso 10 | III | 23 | 20 | Valiant Captivia® (Medtronic) 28 × 157 mm | 21% | 144 | Ausentes |
| Caso 11 | II | 22 | 18 | Valiant Torácica® (Medtronic) com fenestração manual 26 × 164 mm | 18% | 72 |
|
| Caso 12 | II | 22 | 20 | Gore Tag® (L. Gore & Associates, Inc., Delaware, EUA) 26 × 100 mm | 18% | 24 | Ausentes |
| Caso 13 | III | 19 | 16 | Valiant Captivia® (Medtronic) 22 × 100 mm | 15% | 12 | Ausentes |
| Caso 14 | II | 22 | 19 | Endurant II® (Medtronic) 26 × 130 mm | 18% | 48 | Ausentes |
| Caso 15 | III | 28 | 24 | Cook Zenith® (Cook Group Inc., Indiana, EUA) 34 × 34 × 159 mm | 21% | 72 | Ausentes |
| Caso 16 | III | 28 | 23 | Valiant® (Medtronic) 34 × 34 × 150 mm | 21% | 192 | Óbito - não relacionado ao trauma de aorta |