Literature DB >> 34209799

Use of the Taguchi Method to Optimize an Immunodetection System for Quantitative Analysis of a Rapid Test.

Kai-Wen Lin1, Yu-Chi Chang1.   

Abstract

In this research, the Taguchi method was used to optimize the detection accuracy and reproducibility of an immunodetection system used for a quantitative analysis of a rapid test. Furthermore, the standard deviation (SD) and coefficient of variation (CV) between the theoretical value and the measured value of the self-made simulated rapid test became smaller, and the linearity became higher. The results thus indicated that the immunodetection system became more reliable. In the present research, a camera was used to capture an image containing the control line (C line) and the test line (T line) in the self-made simulated rapid test. The captured image was then analyzed, and the grayscales of the C line and T line were calculated. The Taguchi method was used to adjust the light intensity of the light-emitting diode (LED) and the camera parameters in the immunodetection system to determine the optimal parameters by which to optimize the performance of the immunodetection system. The goal of the present research was to obtain a measurement with a minimum SD and CV between the detected grayscales and the grayscales of the self-made simulated rapid test, thus indicating successful development of a practical, stable, and accurate immunodetection system. To mimic the color expression in an actual rapid test, the ratio of the red, green, blue (RGB) components of the self-made simulated rapid test had to be adjusted to closely fit the color expression of the actual rapid test. After the RGB ratio was set, the Taguchi method was used to optimize the parameters for the purpose of detection. When the optimal parameters were found, the signal-to-noise ratio (S/N ratio) had been increased from -12.89 dB to -10.91 dB, which means the accuracy of the color detection had been improved. Compared to the original detection system, the quality loss had been reduced to 33.1%.

Entities:  

Keywords:  Taguchi method; immunodetection system; rapid test

Year:  2021        PMID: 34209799     DOI: 10.3390/diagnostics11071179

Source DB:  PubMed          Journal:  Diagnostics (Basel)        ISSN: 2075-4418


  11 in total

1.  Colloidal gold probe based rapid immunochromatographic strip assay for cortisol.

Authors:  Seema Nara; Vinay Tripathi; Harpal Singh; Tulsidas G Shrivastav
Journal:  Anal Chim Acta       Date:  2010-10-21       Impact factor: 6.558

2.  Integrated rapid-diagnostic-test reader platform on a cellphone.

Authors:  Onur Mudanyali; Stoyan Dimitrov; Uzair Sikora; Swati Padmanabhan; Isa Navruz; Aydogan Ozcan
Journal:  Lab Chip       Date:  2012-05-17       Impact factor: 6.799

3.  A biosensor based on magnetoresistance technology.

Authors:  D R Baselt; G U Lee; M Natesan; S W Metzger; P E Sheehan; R J Colton
Journal:  Biosens Bioelectron       Date:  1998-10-01       Impact factor: 10.618

4.  A prototype of giant magnetoimpedance-based biosensing system for targeted detection of gastric cancer cells.

Authors:  Lei Chen; Chen-Chen Bao; Hao Yang; Ding Li; Chong Lei; Tao Wang; Heng-Yao Hu; Meng He; Yong Zhou; Da-Xiang Cui
Journal:  Biosens Bioelectron       Date:  2010-12-29       Impact factor: 10.618

5.  Rapid lateral flow immunoassay for the fluorescence detection of SARS-CoV-2 RNA.

Authors:  Daming Wang; Shaogui He; Xiaohui Wang; Youqin Yan; Jianzhong Liu; Shimin Wu; Shiguo Liu; Yang Lei; Min Chen; Li Li; Jieli Zhang; Liwei Zhang; Xiao Hu; Xinhui Zheng; Jiawei Bai; Yulong Zhang; Yitong Zhang; Mingxuan Song; Yuguo Tang
Journal:  Nat Biomed Eng       Date:  2020-12-03       Impact factor: 25.671

6.  Modelling of magnetoimpedance response of thin film sensitive element in the presence of ferrogel: Next step toward development of biosensor for in-tissue embedded magnetic nanoparticles detection.

Authors:  N A Buznikov; A P Safronov; I Orue; E V Golubeva; V N Lepalovskij; A V Svalov; A A Chlenova; G V Kurlyandskaya
Journal:  Biosens Bioelectron       Date:  2018-06-20       Impact factor: 10.618

7.  Upconverting nanoparticle reporter-based highly sensitive rapid lateral flow immunoassay for hepatitis B virus surface antigen.

Authors:  Iida Martiskainen; Sheikh M Talha; Karoliina Vuorenpää; Teppo Salminen; Etvi Juntunen; Souvick Chattopadhyay; Dinesh Kumar; Tytti Vuorinen; Kim Pettersson; Navin Khanna; Gaurav Batra
Journal:  Anal Bioanal Chem       Date:  2020-11-23       Impact factor: 4.142

8.  Embedded Immunodetection System for Fecal Occult Blood.

Authors:  Kai-Wen Lin; Yu-Chi Chang
Journal:  Biosensors (Basel)       Date:  2021-04-03

9.  Preparation of colloidal gold immunochromatographic strip for detection of Paragonimiasis skrjabini.

Authors:  Ying Wang; Lifang Wang; Jianwei Zhang; Guangxi Wang; Wenbi Chen; Lin Chen; Xilin Zhang
Journal:  PLoS One       Date:  2014-03-18       Impact factor: 3.240

Review 10.  Enzyme-linked immunosorbent assay for the quantitative/qualitative analysis of plant secondary metabolites.

Authors:  Seiichi Sakamoto; Waraporn Putalun; Sornkanok Vimolmangkang; Waranyoo Phoolcharoen; Yukihiro Shoyama; Hiroyuki Tanaka; Satoshi Morimoto
Journal:  J Nat Med       Date:  2017-11-21       Impact factor: 2.343

View more