Literature DB >> 34208890

Measurement of Electrical Impedance Tomography-Based Regional Ventilation Delay for Individualized Titration of End-Expiratory Pressure.

Thomas Muders1, Benjamin Hentze1, Stefan Kreyer1, Karin Henriette Wodack1, Steffen Leonhardt2, Göran Hedenstierna3, Hermann Wrigge4, Christian Putensen1.   

Abstract

RATIONALE: Individualized positive end-expiratory pressure (PEEP) titration might be beneficial in preventing tidal recruitment. To detect tidal recruitment by electrical impedance tomography (EIT), the time disparity between the regional ventilation curves (regional ventilation delay inhomogeneity [RVDI]) can be measured during controlled mechanical ventilation when applying a slow inflation of 12 mL/kg of body weight (BW). However, repeated large slow inflations may result in high end-inspiratory pressure (PEI), which might limit the clinical applicability of this method. We hypothesized that PEEP levels that minimize tidal recruitment can also be derived from EIT-based RVDI through the use of reduced slow inflation volumes.
METHODS: Decremental PEEP trials were performed in 15 lung-injured pigs. The PEEP level that minimized tidal recruitment was estimated from EIT-based RVDI measurement during slow inflations of 12, 9, 7.5, or 6 mL/kg BW. We compared RVDI and PEI values resulting from different slow inflation volumes and estimated individualized PEEP levels.
RESULTS: RVDI values from slow inflations of 12 and 9 mL/kg BW showed excellent linear correlation (R2 = 0.87, p < 0.001). Correlations decreased for RVDI values from inflations of 7.5 (R2 = 0.68, p < 0.001) and 6 (R2 = 0.42, p < 0.001) mL/kg BW. Individualized PEEP levels estimated from 12 and 9 mL/kg BW were comparable (bias -0.3 cm H2O ± 1.2 cm H2O). Bias and scatter increased with further reduction in slow inflation volumes (for 7.5 mL/kg BW, bias 0 ± 3.2 cm H2O; for 6 mL/kg BW, bias 1.2 ± 4.0 cm H2O). PEI resulting from 9 mL/kg BW inflations were comparable with PEI during regular tidal volumes.
CONCLUSIONS: PEEP titration to minimize tidal recruitment can be individualized according to EIT-based measurement of the time disparity of regional ventilation courses during slow inflations with low inflation volumes. This sufficiently decreases PEI and may reduce potential clinical risks.

Entities:  

Keywords:  acute respiratory distress syndrome; electrical impedance tomography; functional imaging; individualized therapy; monitoring; positive end-expiratory pressure

Year:  2021        PMID: 34208890     DOI: 10.3390/jcm10132933

Source DB:  PubMed          Journal:  J Clin Med        ISSN: 2077-0383            Impact factor:   4.241


  3 in total

1.  Effect of Prone Positioning With Individualized Positive End-Expiratory Pressure in Acute Respiratory Distress Syndrome Using Electrical Impedance Tomography.

Authors:  Liangyu Mi; Yi Chi; Siyi Yuan; Huaiwu He; Yun Long; Inéz Frerichs; Zhanqi Zhao
Journal:  Front Physiol       Date:  2022-06-30       Impact factor: 4.755

2.  Tidal volume significantly affects oxygenation in healthy pigs during high-frequency oscillatory ventilation compared to conventional ventilation.

Authors:  Karel Roubík; Jakub Ráfl; Martin Rožánek; Petr Kudrna; Mikuláš Mlček
Journal:  Biomed Eng Online       Date:  2022-02-13       Impact factor: 2.819

3.  Methods for Determination of Individual PEEP for Intraoperative Mechanical Ventilation Using a Decremental PEEP Trial.

Authors:  Felix Girrbach; Franziska Zeutzschel; Susann Schulz; Mirko Lange; Alessandro Beda; Antonio Giannella-Neto; Hermann Wrigge; Philipp Simon
Journal:  J Clin Med       Date:  2022-06-27       Impact factor: 4.964