Lateral Abdominal Muscles Shear Modulus and Thickness Measurements under Controlled Ultrasound Probe Compression by External Force Sensor: A Comparison and Reliability Study.

Grzegorz Mikołajowski1,2, Małgorzata Pałac1,2, Tomasz Wolny1,2, Paweł Linek1,2.   

Abstract

The aim of this study was to perform a reliability and agreement analysis and to compare lateral abdominal muscles (LAMs) thickness and elasticity results obtained by an experienced operator, by a non-experienced operator, and in an ultrasound imaging probe compression controlled (PCC) condition with minimal force necessary to obtain a proper ultrasound image. The sample consisted of 39 adolescents. An Aixplorer ultrasound scanner was used to evaluate the LAM. The probe in PCC condition was positioned in a prepared probe holder coupled with a pressure sensor. The LAM thickness and elasticity measurements were significantly (p < 0.05) different in the ultrasound PCC condition, compared to results obtained by both examiners. The abdominal oblique external and internal muscle thickness measurements were underestimated and all LAM shear moduli were overestimated during measurements without controlling the probe compression by an external sensor. The intra-class correlation coefficient was excellent in all conditions, but the smallest detectable differences were approximately 43-60% lower during the measurements collected in PCC condition. Differences in LAM measurements between PCC and 'on-hand' conditions may be clinically irrelevant when the force applied by the probe is consciously controlled by the examiner. However, during ultrasound measurements of the LAM morphology, the potential under/over estimation should always be considered when measurements are performed without controlling probe compression by an external sensor.

Entities:  

Keywords:  abdominal muscles; adolescence; elasticity; reliability; reproducibility; shear modulus; thickness; ultrasound imaging; validity

Year:  2021        PMID: 34208168     DOI: 10.3390/s21124036

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  3 in total

1.  Feasibility of Using a Portable MyotonPRO Device to Quantify the Elastic Properties of Skeletal Muscle.

Authors:  Ya-Peng Li; Chun-Long Liu; Zhi-Jie Zhang
Journal:  Med Sci Monit       Date:  2022-01-28

2.  Quantitative Analysis of Abdominal Muscles Using Elastography in Female Patients With Incisional Hernia.

Authors:  Bo Wang; Kai He; Yulan Zhu; Xiaojian Fu; Qiyuan Yao; Hao Chen; Xiaohong Wang
Journal:  Front Surg       Date:  2022-04-12

3.  Intra-Rater Reliability of Shear Wave Elastography for the Quantification of Respiratory Muscles in Adolescent Athletes.

Authors:  Małgorzata Pałac; Paweł Linek
Journal:  Sensors (Basel)       Date:  2022-09-01       Impact factor: 3.847

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.